Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Strip Seal Expansion Joint

2 pages · 3 crops · ×2 · deck

Matched toStrip Seal Expansion Jointbridge.superstructure.expansion_joint_system.strip_sealon “Strip Seal Expansion Joint”

2 read off the drawings · 2 not established
The class asks forValueHowFrom
Joint LengthL_jointwants m/mmnot establishedNo dimension establishing the length of the strip seal expansion joint is provided. The 1070/1236 dimensions are from bearing centreline to expansion-joint centreline, not joint length.not found
Movement RangeMOVwants mmnot establishedThe section states EXP.GAP values of 80(SQ.) and 92(SK), which are shown joint-gap dimensions. It does not state the strip seal joint's movement range/capacity; therefore movement range cannot be established.not found
Instance CountNwants count1 countThe key plan identifies one linear expansion joint marked A1, with its centreline labelled "C OF EXP. JOINT".readp1 · p01_r01 key plan
Material TypeMATstrip seal type expansion joint -General Note 8 specifies that a "STRIP SEAL TYPE OF EXPANSION JOINT" shall be provided as per MORTH specification.readp2 · p02_r03 notes

Worked out by openai/gpt-5.6-terra-pro from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

How the sheets named it

expansion jointstrip seal type expansion jointA1

Every dimension read for it2

  • 80(SQ.)EXP.GAPp2 · p02_r05 section a a
  • 92(SK)EXP.GAPp2 · p02_r05 section a a

Notes on the sheets that carry it

  • p1C OF EXP. JOINT
  • p1INDEPENDENT RETAINING WALL
  • p1MEDIAN WALL PCC M15
  • p1RET. TOE WALL
  • p1WING FOUNDATION LEVEL (partial)
  • p21. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
  • p22. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
  • p23. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
  • p24. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
  • p25. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-
  • p26. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS:
  • p27. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.
  • p28. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.
  • p29. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.
  • p210. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.
  • p211. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.
  • p212. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.
  • p213. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & ’SEVERE’ EXPOSURE CONDITION.
  • p214. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.
  • p215. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°,γ=2T/m³
  • p216. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.
  • p217. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.
  • p218. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:–
  • p2POT-PTFE BEARING (TYP.)
  • p2RCC SEISMIC STOPPER
  • p2STONE PITCHING
  • p2600 THK. FILTER MEDIA
  • p21200 DIA BORED CAST-IN-SITU PILES

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r01 key plan

page 1 · structural_drawings_pkg_1_cede2c5e58c24d1b92ee5a813c5fab4c_p01_r01_key_plan
Original
p01_r01 key plan
{
  "view": "Plan",
  "objects": [
    {
      "name": "proposed structure",
      "tag": "",
      "shape": "skewed rectangular",
      "material": "",
      "count": 1,
      "note": "Shown as a hatched crossing in the key plan; structure type is noted as MUBR."
    },
    {
      "name": "pile",
      "tag": "",
      "shape": "circular",
      "material": "",
      "count": 40,
      "note": "Circular pile symbols are visible in two foundation groups."
    },
    {
      "name": "skewed rectangular · ×2",
      "tag": "",
      "shape": "tapered trapezoidal",
      "material": "",
      "count": 2,
      "note": "Two large skewed/tapered pile-supported foundation outlines are partially shown."
    },
    {
      "name": "independent retaining wall",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "One wall is called out at each visible end of the foundation arrangement."
    },
    {
      "name": "median wall",
      "tag": "",
      "shape": "rectangular",
      "material": "PCC M15",
      "count": 1,
      "note": "Located between the two visible foundation groups."
    },
    {
      "name": "expansion joint",
      "tag": "A1",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Centre line is marked \"C OF EXP. JOINT\"."
    }
  ],
  "measurements": [
    {
      "label": "Proposed chainage",
      "value": "64+412",
      "unit": "",
      "appliesTo": "proposed structure"
    },
    {
      "label": "Proposed span",
      "value": "2x40m",
      "unit": "",
      "appliesTo": "proposed structure"
    },
    {
      "label": "Skew",
      "value": "30°",
      "unit": "",
      "appliesTo": "proposed structure"
    },
    {
      "label": "Chainage",
      "value": "64+400",
      "unit": "",
      "appliesTo": "RET. TOE WALL"
    },
    {
      "label": "Chainage",
      "value": "64+500",
      "unit": "",
      "appliesTo": "RET. TOE WALL"
    },
    {
      "label": "Dimension",
      "value": "775",
      "unit": "",
      "appliesTo": "foundation layout"
    },
    {
      "label": "Pile spacing dimension",
      "value": "3750",
      "unit": "",
      "appliesTo": "pile layout"
    },
    {
      "label": "Overall dimension",
      "value": "16550",
      "unit": "",
      "appliesTo": "foundation layout"
    },
    {
      "label": "Scale",
      "value": "1:2000",
      "unit": "",
      "appliesTo": "KEY PLAN"
    }
  ],
  "notes": [
    "C OF EXP. JOINT",
    "INDEPENDENT RETAINING WALL",
    "MEDIAN WALL PCC M15",
    "RET. TOE WALL",
    "WING FOUNDATION LEVEL (partial)"
  ],
  "labels": [
    "KEY PLAN",
    "PROPOSED CH: 64+412",
    "STRUCTURE TYPE MUBR",
    "PROPOSED SPAN 2x40m",
    "SKEW 30°",
    "PROPOSAL New Construction",
    "TO DEWAS",
    "TO KHANDWA",
    "ROW",
    "Shipra River",
    "Earthen Drain",
    "Agriculture land",
    "N",
    "E",
    "S",
    "W"
  ],
  "description": "This crop contains a key plan for a proposed skewed MUBR crossing at proposed chainage 64+412, together with a partial pile-supported foundation layout. The foundation layout shows two tapered pile groups, independent retaining walls at the outer ends, a median wall in PCC M15, and an expansion-joint centreline reference."
}

p01_r01 key planPlan

  • expansion jointA1×1linearCentre line is marked "C OF EXP. JOINT".

64+412 Proposed chainage2x40m Proposed span30° Skew64+400 Chainage64+500 Chainage775 Dimension3750 Pile spacing dimension16550 Overall dimension+1 more

Page 2

crop

p02_r03 notes

page 2 · structural_drawings_pkg_1_cede2c5e58c24d1b92ee5a813c5fab4c_p02_r03_notes
Original
p02_r03 notes
{
  "view": "Notes",
  "objects": [
    {
      "name": "PSC precast girder",
      "tag": "",
      "shape": "",
      "material": "precast concrete",
      "count": null,
      "note": "Concrete grade specified as M50."
    },
    {
      "name": "cast in situ deck slab",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade specified as M45."
    },
    {
      "name": "end cross girder",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade specified as M45."
    },
    {
      "name": "intermediate cross girder",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade specified as M45."
    },
    {
      "name": "bearing pedestal",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M50."
    },
    {
      "name": "crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M40."
    },
    {
      "name": "approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M30."
    },
    {
      "name": "levelling course",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M15."
    },
    {
      "name": "dirt wall & slab",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M35."
    },
    {
      "name": "abutment",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M45."
    },
    {
      "name": "pier",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M45."
    },
    {
      "name": "pile foundation",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade specified as M35; tentative working pile loads are stated."
    },
    {
      "name": "reinforcing steel bars",
      "tag": "",
      "shape": "deformed",
      "material": "high yield strength steel",
      "count": null,
      "note": "TMT bars of grade-Fe 550D, conforming to IS: 1786."
    },
    {
      "name": "strip seal type expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "To be provided as per M O R T H specification."
    },
    {
      "name": "bituminous concrete",
      "tag": "",
      "shape": "single layer",
      "material": "bituminous concrete",
      "count": null,
      "note": "Laid in single layer."
    },
    {
      "name": "drainage spout",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "To be provided in deck slab as per M O R T H specification."
    },
    {
      "name": "back filling material",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Behind abutment; to be well compacted."
    },
    {
      "name": "RE wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Selected earth fill behind RE wall is specified."
    },
    {
      "name": "bearing",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Bearing height is referenced in relation to a 200mm pedestal."
    },
    {
      "name": "piercap",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Top level fixed considering bearing and pedestal depth."
    },
    {
      "name": "gap slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Refer miscellaneous drawing for dimension and reinforcement details."
    }
  ],
  "measurements": [
    {
      "label": "PSC PRECAST GIRDER concrete grade",
      "value": "M50",
      "unit": "",
      "appliesTo": "PSC precast girder"
    },
    {
      "label": "R.C.C. CAST IN SITU DECK SLAB concrete grade",
      "value": "M45",
      "unit": "",
      "appliesTo": "cast in situ deck slab"
    },
    {
      "label": "R.C.C. END CROSS GIRDER concrete grade",
      "value": "M45",
      "unit": "",
      "appliesTo": "end cross girder"
    },
    {
      "label": "R.C.C. INTERMEDIATE CROSS GIRDER concrete grade",
      "value": "M45",
      "unit": "",
      "appliesTo": "intermediate cross girder"
    },
    {
      "label": "BEARING PEDESTAL concrete grade",
      "value": "M50",
      "unit": "",
      "appliesTo": "bearing pedestal"
    },
    {
      "label": "CRASH BARRIER concrete grade",
      "value": "M40",
      "unit": "",
      "appliesTo": "crash barrier"
    },
    {
      "label": "APPROACH SLAB concrete grade",
      "value": "M30",
      "unit": "",
      "appliesTo": "approach slab"
    },
    {
      "label": "LEVELLING COURSE concrete grade",
      "value": "M15",
      "unit": "",
      "appliesTo": "levelling course"
    },
    {
      "label": "DIRT WALL & SLAB concrete grade",
      "value": "M35",
      "unit": "",
      "appliesTo": "dirt wall & slab"
    },
    {
      "label": "ABUTMENT & PIER concrete grade",
      "value": "M45",
      "unit": "",
      "appliesTo": "abutment & pier"
    },
    {
      "label": "PILE FOUNDATION concrete grade",
      "value": "M35",
      "unit": "",
      "appliesTo": "pile foundation"
    },
    {
      "label": "Foundation clear cover to reinforcements",
      "value": "75",
      "unit": "mm",
      "appliesTo": "foundation"
    },
    {
      "label": "Substructure abutment & abutment cap clear cover to reinforcements",
      "value": "45",
      "unit": "mm",
      "appliesTo": "abutment & abutment cap"
    },
    {
      "label": "Substructure pier & pier cap clear cover to reinforcements",
      "value": "45",
      "unit": "mm",
      "appliesTo": "pier & pier cap"
    },
    {
      "label": "Superstructure clear cover to reinforcements",
      "value": "45",
      "unit": "mm",
      "appliesTo": "superstructure"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "reinforcing steel bars"
    },
    {
      "label": "Bituminous concrete thickness",
      "value": "50",
      "unit": "MM",
      "appliesTo": "bituminous concrete"
    },
    {
      "label": "Selected earth fill cohesion",
      "value": "C=0",
      "unit": "",
      "appliesTo": "selected earth fill behind RE wall"
    },
    {
      "label": "Selected earth fill friction angle",
      "value": "ø>32°",
      "unit": "",
      "appliesTo": "selected earth fill behind RE wall"
    },
    {
      "label": "Selected earth fill unit weight",
      "value": "γ=2",
      "unit": "T/m³",
      "appliesTo": "selected earth fill behind RE wall"
    },
    {
      "label": "Depth of BRG. & PEDESTAL",
      "value": "400 mm — on bearing & pedestal",
      "unit": "mm",
      "appliesTo": "piercap"
    },
    {
      "label": "Bearing height threshold",
      "value": "200",
      "unit": "mm",
      "appliesTo": "bearing"
    },
    {
      "label": "Pedestal height",
      "value": "200",
      "unit": "mm",
      "appliesTo": "pedestal"
    },
    {
      "label": "MAX. VERTICAL LOAD",
      "value": "300",
      "unit": "T",
      "appliesTo": "pile"
    },
    {
      "label": "LATERAL LOAD",
      "value": "50",
      "unit": "T",
      "appliesTo": "pile"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "5. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-",
    "6. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS:",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.",
    "8. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.",
    "9. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.",
    "10. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.",
    "11. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.",
    "12. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.",
    "13. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & ’SEVERE’ EXPOSURE CONDITION.",
    "14. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.",
    "15. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°,γ=2T/m³",
    "16. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.",
    "17. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.",
    "18. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:–"
  ],
  "labels": [
    "NOTES:",
    "FOUNDATION",
    "SUBSTRUCTURE",
    "SUPERSTRUCTURE",
    "ABUTMENT & ABUTMENT CAP",
    "PIER & PIER CAP",
    "MAX. VERTICAL LOAD",
    "LATERAL LOAD"
  ],
  "description": "This crop is a general notes block for a bridge drawing. It states drawing conventions, design loading, material grades, reinforcement cover, construction requirements, exposure conditions, and tentative pile working loads."
}

p02_r03 notesNotes

  • strip seal type expansion jointTo be provided as per M O R T H specification.

M50 PSC PRECAST GIRDER concrete gradeM45 R.C.C. CAST IN SITU DECK SLAB concrete gradeM45 R.C.C. END CROSS GIRDER concrete gradeM45 R.C.C. INTERMEDIATE CROSS GIRDER concrete gradeM50 BEARING PEDESTAL concrete gradeM40 CRASH BARRIER concrete gradeM30 APPROACH SLAB concrete gradeM15 LEVELLING COURSE concrete grade+17 more

crop

p02_r05 section a a

page 2 · structural_drawings_pkg_1_cede2c5e58c24d1b92ee5a813c5fab4c_p02_r05_section_a_a
Original
p02_r05 section a a
{
  "view": "Section",
  "objects": [
    {
      "name": "bridge deck slab",
      "tag": "",
      "shape": "rectangular horizontal slab",
      "material": "",
      "count": 1,
      "note": "Shown across the top of the section with an expansion joint."
    },
    {
      "name": "expansion joint",
      "tag": "",
      "shape": "narrow vertical joint",
      "material": "",
      "count": 1,
      "note": "Located at the centreline marked C/L OF EXP. JOINT."
    },
    {
      "name": "rectangular bearing · POT-PTFE · ×1 · Callout states POT-PTFE BEARING (TYP.).",
      "tag": "",
      "shape": "rectangular laminated bearing",
      "material": "POT-PTFE",
      "count": 1,
      "note": "Callout states POT-PTFE BEARING (TYP.)."
    },
    {
      "name": "seismic stopper",
      "tag": "",
      "shape": "rectangular",
      "material": "RCC",
      "count": 1,
      "note": "Located adjacent to the bearing."
    },
    {
      "name": "abutment",
      "tag": "",
      "shape": "rectangular stem and footing",
      "material": "",
      "count": 1,
      "note": "Supports the bearing and superstructure."
    },
    {
      "name": "approach embankment",
      "tag": "",
      "shape": "sloping",
      "material": "",
      "count": 1,
      "note": "Sloping fill is shown to the left of the abutment."
    },
    {
      "name": "stone pitching",
      "tag": "",
      "shape": "sloping layer",
      "material": "stone",
      "count": 1,
      "note": "Shown on the retaining-wall-side slope."
    },
    {
      "name": "independent retaining wall",
      "tag": "",
      "shape": "vertical wall",
      "material": "",
      "count": 1,
      "note": "Shown to the right of the abutment."
    },
    {
      "name": "layer · ×1 · Shown immediately behind the abutment along the sloping fill.",
      "tag": "",
      "shape": "layer",
      "material": "",
      "count": 1,
      "note": "Shown behind the independent retaining wall."
    },
    {
      "name": "pile cap",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Outlined with dashed lines below the abutment."
    },
    {
      "name": "bored cast-in-situ piles",
      "tag": "",
      "shape": "circular",
      "material": "",
      "count": 4,
      "note": "Four pile symbols are visible below the pile cap."
    }
  ],
  "measurements": [
    {
      "label": "C/L OF BRG. to C/L OF EXP. JOINT",
      "value": "1070 (SQ.)",
      "unit": "",
      "appliesTo": "bearing / expansion joint"
    },
    {
      "label": "C/L OF BRG. to C/L OF EXP. JOINT",
      "value": "1236 (SK.)",
      "unit": "",
      "appliesTo": "bearing / expansion joint"
    },
    {
      "label": "EXP.GAP",
      "value": "80(SQ.)",
      "unit": "",
      "appliesTo": "expansion joint"
    },
    {
      "label": "EXP.GAP",
      "value": "92(SK)",
      "unit": "",
      "appliesTo": "expansion joint"
    },
    {
      "label": "horizontal dimension",
      "value": "3500(SQ)",
      "unit": "",
      "appliesTo": "deck / abutment"
    },
    {
      "label": "vertical dimension",
      "value": "230",
      "unit": "",
      "appliesTo": "deck"
    },
    {
      "label": "vertical dimension",
      "value": "2650",
      "unit": "",
      "appliesTo": "superstructure"
    },
    {
      "label": "horizontal dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": "superstructure"
    },
    {
      "label": "horizontal dimension",
      "value": "2850",
      "unit": "",
      "appliesTo": "superstructure / abutment"
    },
    {
      "label": "horizontal dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": "abutment"
    },
    {
      "label": "pile cap end projection",
      "value": "750",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile spacing",
      "value": "3600",
      "unit": "",
      "appliesTo": "bored cast-in-situ piles"
    },
    {
      "label": "pile spacing",
      "value": "3600",
      "unit": "",
      "appliesTo": "bored cast-in-situ piles"
    },
    {
      "label": "pile spacing",
      "value": "3600",
      "unit": "",
      "appliesTo": "bored cast-in-situ piles"
    },
    {
      "label": "pile cap length",
      "value": "12300",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap end projection",
      "value": "750",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "filter media thickness",
      "value": "600",
      "unit": "",
      "appliesTo": "filter media"
    },
    {
      "label": "pile diameter",
      "value": "1200",
      "unit": "",
      "appliesTo": "bored cast-in-situ piles"
    },
    {
      "label": "scale",
      "value": "1:150",
      "unit": "",
      "appliesTo": "SECTION A-A"
    }
  ],
  "notes": [
    "POT-PTFE BEARING (TYP.)",
    "RCC SEISMIC STOPPER",
    "STONE PITCHING",
    "INDEPENDENT RETAINING WALL",
    "600 THK. FILTER MEDIA",
    "1200 DIA BORED CAST-IN-SITU PILES"
  ],
  "labels": [
    "A2",
    "C/L OF EXP. JOINT",
    "C/L OF BRG.",
    "EXP.GAP",
    "SECTION A-A",
    "(SCALE 1:150)",
    "1",
    "2"
  ],
  "description": "This crop shows Section A-A through a bridge abutment and adjacent independent retaining wall. It documents the deck expansion joint, bearing and RCC seismic stopper, abutment on a piled foundation, approach embankment, stone pitching, and filter media behind the retaining wall."
}

p02_r05 section a aSection

  • expansion joint×1narrow vertical jointLocated at the centreline marked C/L OF EXP. JOINT.

1070 (SQ.) C/L OF BRG. to C/L OF EXP. JOINT1236 (SK.) C/L OF BRG. to C/L OF EXP. JOINT80(SQ.) EXP.GAP92(SK) EXP.GAP3500(SQ) horizontal dimension230 vertical dimension2650 vertical dimension1500 horizontal dimension+11 more