Matched toPrestressed Concrete Girderbridge.superstructure.main_load_system.psc_girderon “PSC Girder”
| The class asks for | Value | How | From |
|---|---|---|---|
| Span LengthL_spanwants m/mm | 40000(SQ) 46188(SK) (A1 to P1); 46000(SK) 46188(SK) (P1 to A2) mmThe elevation labels these as span dimensions for the two spans containing the precast PSC girder. The general notes state that dimensions are in millimeters unless otherwise specified. The dimensions are not explicitly labelled as girder lengths, so they are reported as the span dimensions exactly as written. | readcheck | p2 · p02_r01 notes |
| Cross-sectional AreaAwants m2/mm2 | 1110000 mm2MID SECTION area = top flange + top tapered portion + web + lower tapered portion + bottom flange = (1000 × 150) + [((1000 + 300) ÷ 2) × 100] + (300 × 1950) + [((300 + 800) ÷ 2) × 200] + (800 × 250) = 150000 + 65000 + 585000 + 110000 + 200000 = 1110000 mm2.The MID SECTION dimensions unambiguously define the full girder profile: 1000 mm top width, 300 mm web width, 800 mm bottom width, and vertical portions of 150 mm, 100 mm, 1950 mm, 200 mm, and 250 mm. These portions total the stated overall depth of 2650 mm. | derived | p2 · p02_r02 mid section |
| Instance CountNwants count | 2 countThe elevation identifies two precast PSC girders and notes that one girder line is shown in each span. | read | p2 · p02_r01 notes |
| Concrete Gradefck | M50The concrete-grade schedule explicitly states PSC PRECAST GIRDER concrete grade as M50. | read | p2 · p02_r03 notes |
Worked out by openai/gpt-5.6-terra-pro from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.
How the sheets named it
Every dimension read for it19
- 150top flange thicknessp2 · p02_r02 mid section
- 1000top widthp2 · p02_r02 mid section
- 29top haunch depthp2 · p02_r02 mid section
- 2650overall depthp2 · p02_r02 mid section
- 800bottom widthp2 · p02_r02 mid section
- 150top flange thicknessp2 · p02_r02 mid section
- 1000top widthp2 · p02_r02 mid section
- 2650overall depthp2 · p02_r02 mid section
- 100top tapered portion depthp2 · p02_r02 mid section
- 1950web vertical dimensionp2 · p02_r02 mid section
- 200lower tapered portion depthp2 · p02_r02 mid section
- 300web widthp2 · p02_r02 mid section
- 250bottom flange thicknessp2 · p02_r02 mid section
- 800bottom widthp2 · p02_r02 mid section
- 1:50scalep2 · p02_r02 mid section
- 1:50scalep2 · p02_r02 mid section
- M50PSC PRECAST GIRDER concrete gradep2 · p02_r03 notes
- 2650girder depthp2 · p02_r04 section b b
- 2650girder depthp2 · p02_r04 section b b
Notes on the sheets that carry it
- p21. ALL DIMENSIONS AR… OTHERWISE SPECIFIED.
- p22. DIMENSIONS ARE IN… FOLLOWED.
- p23. THIS DRAWING SHAL… ALIGNMENT DRAWIN…
- p24. THE BRIDGE HAS B… CLASS 70R + TWO… 70R OR SV LOADING
- p25. GRADE OF CONCRE… FOLLOWS:
- p2• PSC PRECAST GIR…
- p2• R.C.C. CAST IN S…
- p2• R.C.C. ENDORSE…
- p21. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
- p22. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
- p23. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
- p24. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
- p25. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-
- p26. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS:
- p27. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.
- p28. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.
- p29. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.
- p210. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.
- p211. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.
- p212. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.
- p213. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & ’SEVERE’ EXPOSURE CONDITION.
- p214. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.
- p215. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°,γ=2T/m³
- p216. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.
- p217. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.
- p218. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:–
- p2RCC CRASH BARRIER
- p2FRL
- p2DECK CONTINUITY
- p2PRECAST PSC GIRDER (TYP.)
- p2RCC SEISMIC STOPPER
- p2POT-PTFE BEARING (TYP.)
- p2RCC COLUMN PIER
- p2RCC PILECAP
- p21200 DIA BORED CAST-IN-SITU PILES
Every crop it was read in — the drawing beside what the model took off it
Page 2
p02_r01 notesElevation
- precast PSC girder×2rectangular girder elevationprecast PSCMarked TYP.; one girder line is shown in each span.
40000(SQ) 46188(SK) span dimension46000(SK) 46188(SK) span dimension37761(SQ) 43602(SK) bridge length dimension37761(SQ) 43602(SK) bridge length dimension80(SQ) 92(SK) expansion gap80(SQ) 92(SK) expansion gap1070(SQ) 1236(SK) end offset1170(SQ) 1350(SK) pier-side offset+34 more
p02_r02 mid sectionCross Section
- precast PSC girder · rectangular stem with widened top flange · precast prestressed concrete · Support cross-section profile shown.SUPPORT SECTION×1rectangular stem with widened top flangeprecast prestressed concreteSupport cross-section profile shown.
- precast PSC girder · I-girder with tapered haunches and widened top and bottom flanges · precast prestressed concrete · Mid-span cross-section profile shown.MID SECTION×1I-girder with tapered haunches and widened top and bottom flangesprecast prestressed concreteMid-span cross-section profile shown.
150 top flange thickness1000 top width29 top haunch depth2650 overall depth800 bottom width150 top flange thickness1000 top width2650 overall depth+8 more
p02_r03 notesNotes
- PSC precast girderprecast concreteConcrete grade specified as M50.
M50 PSC PRECAST GIRDER concrete gradeM45 R.C.C. CAST IN SITU DECK SLAB concrete gradeM45 R.C.C. END CROSS GIRDER concrete gradeM45 R.C.C. INTERMEDIATE CROSS GIRDER concrete gradeM50 BEARING PEDESTAL concrete gradeM40 CRASH BARRIER concrete gradeM30 APPROACH SLAB concrete gradeM15 LEVELLING COURSE concrete grade+17 more
p02_r04 section b bSection
- precast PSC girder×2precast girderprecast PSC(TYP.)
1170(SQ) bearing centreline offset, SQ1350(SK) bearing centreline offset, SK230 deck depth230 deck depth2650 girder depth2650 girder depth1500(SK) horizontal dimension1500 vertical dimension+11 more