Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Footpath

2 pages · 2 crops · ×6 · pavement

Matched toBridge Footpathbridge.superstructure.deck_system.footpathon “Footpath”

2 read off the drawings · 1 derived · 1 not established
The class asks forValueHowFrom
LengthLwants m/mm80 m2 × 40M = 80 m.The plan identifies two footpaths along the outside edges of the bridge decks and states the proposed bridge span as 2X40M. The footpath length is taken as the full bridge span length; this association is not explicitly dimensioned to the footpath.derivedcheckp1 · p01_r02 details of hydraulic data
WidthWwants m/mm1500 mmRead directly as footpath width.The transverse section explicitly labels a dimension of 1500 as applying to FOOTPATH. The drawing notes establish that dimensions are in millimeters unless otherwise specified.readp3 · p03_r02 section at abutment location at a1 a2
ThicknessTwants m/mmnot establishedNo reading explicitly assigns a thickness to the footpath. The 50mm thickness is explicitly identified as wearing course (WC), not footpath thickness; the plan's 450, 100, and 150 footpath-related dimensions are not assigned to thickness.not found
Instance CountNwants count2 countRead directly from the plan object count for Footpath.The deck-level plan identifies Footpath with count 2, corresponding to footpaths at the outside edges of the two carriageways.readp1 · p01_r02 details of hydraulic data

Worked out by openai/gpt-5.6-terra-pro from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

Every dimension read for it4

  • 450Footpath dimensionsp1 · p01_r02 details of hydraulic data
  • 100Footpath dimensionsp1 · p01_r02 details of hydraulic data
  • 150Footpath dimensionsp1 · p01_r02 details of hydraulic data
  • 1500footpath widthp3 · p03_r02 section at abutment location at a1 a2

Notes on the sheets that carry it

  • p11. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
  • p12. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
  • p13. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
  • p350mm THK. (WC)
  • p3RCC CAST IN SITU DECK SLOPE 2.5%
  • p320mm GAP FILLED WITH POLYSULPHIDE SEALANT
  • p3CANTILEVER MEDIAN WALL
  • p3READ THIS DRAWING IN CONJUNCTION WITH OTHER SHEETS OF THE SAME DRAWING NUMBER

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r02 details of hydraulic data

page 1 · structural_drawings_pkg_1_cede2c5e58c24d1b92ee5a813c5fab4c_p01_r02_details_of_hydraulic_data
Original
p01_r02 details of hydraulic data
{
  "view": "Plan",
  "objects": [
    {
      "name": "Bridge deck/carriageway",
      "tag": "",
      "shape": "skewed rectangular",
      "material": "",
      "count": 2,
      "note": "Two parallel carriageway decks are shown in the half plan at deck level."
    },
    {
      "name": "RCC crash barrier",
      "tag": "",
      "shape": "linear",
      "material": "reinforced cement concrete",
      "count": 4,
      "note": "Shown along the outer edges and beside the median; callout reads RCC CRASH BARRIER."
    },
    {
      "name": "Footpath",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Footpaths are indicated at the outside edges of the two carriageways."
    },
    {
      "name": "Abutment",
      "tag": "A1",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Located at the two ends adjacent to the expansion-joint callouts."
    },
    {
      "name": "Pier",
      "tag": "P1",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "A central support line is tagged P1."
    },
    {
      "name": "Median wall",
      "tag": "",
      "shape": "linear",
      "material": "PCC M15",
      "count": 1,
      "note": "Callout reads MEDIAN WALL PCC M15."
    },
    {
      "name": "Independent retaining wall",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "One is shown at each end of the foundation-level half plan."
    },
    {
      "name": "Borehole location",
      "tag": "",
      "shape": "circular",
      "material": "",
      "count": null,
      "note": "Circular symbols are shown in the foundation-level half plan; the legend identifies the symbol as BOREHOLE LOCATION."
    }
  ],
  "measurements": [
    {
      "label": "Right-of-way width",
      "value": "80000",
      "unit": "",
      "appliesTo": "ROW"
    },
    {
      "label": "Right-of-way width",
      "value": "40000",
      "unit": "",
      "appliesTo": "Each side of ROW"
    },
    {
      "label": "Carriageway width",
      "value": "16550",
      "unit": "",
      "appliesTo": "Each carriageway"
    },
    {
      "label": "Carriageway width",
      "value": "13500",
      "unit": "",
      "appliesTo": "Carriageway"
    },
    {
      "label": "Median width",
      "value": "2900",
      "unit": "",
      "appliesTo": "Median"
    },
    {
      "label": "Footpath dimensions",
      "value": "450",
      "unit": "",
      "appliesTo": "Footpath"
    },
    {
      "label": "Footpath dimensions",
      "value": "100",
      "unit": "",
      "appliesTo": "Footpath"
    },
    {
      "label": "Footpath dimensions",
      "value": "150",
      "unit": "",
      "appliesTo": "Footpath"
    },
    {
      "label": "Lane/segment width",
      "value": "3500",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "RCC crash barrier spacing",
      "value": "5000",
      "unit": "",
      "appliesTo": "RCC CRASH BARRIER (TYP.)"
    },
    {
      "label": "Skew",
      "value": "30°",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Dimension",
      "value": "1275",
      "unit": "",
      "appliesTo": "Deck/foundation plan"
    },
    {
      "label": "Dimension",
      "value": "775",
      "unit": "",
      "appliesTo": "Foundation plan"
    },
    {
      "label": "Dimension",
      "value": "3750",
      "unit": "",
      "appliesTo": "Foundation plan"
    },
    {
      "label": "Square alignment length",
      "value": "40000(SQ)",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "Skew alignment length",
      "value": "46189(SK)",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "Square alignment length",
      "value": "37761(SQ)",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "Skew alignment length",
      "value": "43603(SK)",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "Square alignment length",
      "value": "1170(SQ)",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "Skew alignment length",
      "value": "1350(SK)",
      "unit": "",
      "appliesTo": "Deck plan"
    },
    {
      "label": "Key-plan chainage",
      "value": "64+412",
      "unit": "",
      "appliesTo": "PROPOSED CH."
    },
    {
      "label": "Proposed span",
      "value": "2X40M",
      "unit": "",
      "appliesTo": "PROPOSED SPAN"
    },
    {
      "label": "Key-plan skew",
      "value": "30°",
      "unit": "",
      "appliesTo": "SKEW"
    },
    {
      "label": "Key plan scale",
      "value": "1:2000",
      "unit": "",
      "appliesTo": "KEY PLAN"
    },
    {
      "label": "Plan scale",
      "value": "1:300",
      "unit": "",
      "appliesTo": "HALF PLAN SHOWING DECK LEVEL / HALF PLAN SHOWING FOUNDATION LEVEL"
    },
    {
      "label": "Minimum discharge for 100 year return period",
      "value": "2472.52",
      "unit": "m³/S",
      "appliesTo": "DETAILS OF HYDRAULIC DATA"
    },
    {
      "label": "Free board",
      "value": "1.20",
      "unit": "m.",
      "appliesTo": "DETAILS OF HYDRAULIC DATA"
    },
    {
      "label": "Velocity",
      "value": "1.31",
      "unit": "m/s",
      "appliesTo": "DETAILS OF HYDRAULIC DATA"
    },
    {
      "label": "HFL",
      "value": "513.76",
      "unit": "m.",
      "appliesTo": "DETAILS OF HYDRAULIC DATA"
    },
    {
      "label": "Lowest bed level",
      "value": "503.75",
      "unit": "m.",
      "appliesTo": "DETAILS OF HYDRAULIC DATA"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS."
  ],
  "labels": [
    "TO DEWAS",
    "TO KHANDWA",
    "TO PIKARADIYA",
    "C/L OF EXP. JOINT",
    "C/L OF MEDIAN",
    "C/L OF APPROACH SLAB",
    "RIGHT SIDE",
    "LEFT SIDE",
    "HALF PLAN SHOWING DECK LEVEL",
    "HALF PLAN SHOWING FOUNDATION LEVEL",
    "KEY PLAN",
    "PROPOSED CH: 64+412",
    "PROPOSED TYPE: MAJOR",
    "PROPOSED SPAN: 2X40M",
    "SKEW: 30°",
    "PROPOSAL: New Construction",
    "RET/ TOE WALL",
    "LEGEND :",
    "BOREHOLE LOCATION",
    "RCC ----- REINFORCED CEMENT CONCRETE",
    "PCC ----- PLAIN CEMENT CONCRETE",
    "GL ----- GROUND LEVEL",
    "CL ----- CENTER LINE",
    "FDN ----- FOUNDATION",
    "LVL ----- LEVEL",
    "ABTL ----- ABUTMENT CAP TOP LEVEL",
    "PCTL ----- PIER CAP TOP LEVEL",
    "DETAILS OF HYDRAULIC DATA",
    "MIN. DISCHARGE FOR 100 YEAR RETURN PERIOD",
    "FREE BOARD",
    "VELOCITY",
    "HFL",
    "LOWEST BED LEVEL"
  ],
  "description": "The crop shows a general arrangement plan of a skew major bridge, including two carriageway deck plans and a corresponding half plan showing foundation level. It also includes a key plan, legend, hydraulic-data table, retaining-wall indications, and general drawing notes."
}

p01_r02 details of hydraulic dataPlan

  • Footpath×2linearFootpaths are indicated at the outside edges of the two carriageways.

80000 Right-of-way width40000 Right-of-way width16550 Carriageway width13500 Carriageway width2900 Median width450 Footpath dimensions100 Footpath dimensions150 Footpath dimensions+22 more

Page 3

crop

p03_r02 section at abutment location at a1 a2

page 3 · structural_drawings_pkg_1_cede2c5e58c24d1b92ee5a813c5fab4c_p03_r02_section_at_abutment_location_at_a1_a2
Original
p03_r02 section at abutment location at a1 a2
{
  "view": "Section",
  "objects": [
    {
      "name": "crash barrier",
      "tag": "",
      "shape": "profiled barrier",
      "material": "RCC",
      "count": 4,
      "note": "Labeled RCC CRASH BARRIER at the outside edges of the roadway sections."
    },
    {
      "name": "footpath",
      "tag": "",
      "shape": "rectangular strip",
      "material": "",
      "count": 4,
      "note": "Shown adjacent to the outside crash barriers."
    },
    {
      "name": "Deck is called out as RCC CAST IN SITU DECK with 2.5% slope; the adjacent 50mm THK. (WC) callout applies to the wearing course.",
      "tag": "",
      "shape": "sloping slab",
      "material": "RCC cast in situ",
      "count": 4,
      "note": "Deck is called out with 2.5% slope and 50mm THK. (WC)."
    },
    {
      "name": "abutment",
      "tag": "A1 / A2",
      "shape": "rectangular wall and cap",
      "material": "",
      "count": 2,
      "note": "Upper section shows the abutment locations at A1 and A2."
    },
    {
      "name": "cantilever median wall",
      "tag": "PCC MW A2",
      "shape": "rectangular wall",
      "material": "PCC",
      "count": 1,
      "note": "Located at the central median in the abutment section."
    },
    {
      "name": "pile cap",
      "tag": "PCBL A1 / A2",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Shown below the A1 and A2 abutments."
    },
    {
      "name": "pile",
      "tag": "A1 / A2",
      "shape": "vertical",
      "material": "",
      "count": 10,
      "note": "Five piles are visible below each abutment pile cap."
    },
    {
      "name": "pier cap",
      "tag": "P1",
      "shape": "rectangular tapered top",
      "material": "",
      "count": 2,
      "note": "Shown in the lower pier-location section."
    },
    {
      "name": "pier column",
      "tag": "P1",
      "shape": "rectangular vertical",
      "material": "",
      "count": 4,
      "note": "Two columns are visible at each pier location."
    },
    {
      "name": "pile cap",
      "tag": "PCBL P1",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Shown below the P1 pier columns."
    },
    {
      "name": "pile",
      "tag": "P1",
      "shape": "vertical",
      "material": "",
      "count": 10,
      "note": "Five piles are visible below each P1 pile cap."
    },
    {
      "name": "approach embankment",
      "tag": "",
      "shape": "sloping",
      "material": "",
      "count": 2,
      "note": "Shown only in the upper abutment section, with rock-protection pattern at the toes."
    }
  ],
  "measurements": [
    {
      "label": "right of way width",
      "value": "80000",
      "unit": "",
      "appliesTo": "ROW"
    },
    {
      "label": "right of way half-width",
      "value": "40000",
      "unit": "",
      "appliesTo": "ROW"
    },
    {
      "label": "centreline of proposed road",
      "value": "29000",
      "unit": "",
      "appliesTo": "C OF PROPOSED ROAD"
    },
    {
      "label": "section width",
      "value": "16550",
      "unit": "",
      "appliesTo": "A1/A2 and P1 roadway-side sections"
    },
    {
      "label": "carriageway width",
      "value": "13500",
      "unit": "",
      "appliesTo": "CARRIAGEWAY"
    },
    {
      "label": "edge width",
      "value": "450",
      "unit": "",
      "appliesTo": "roadway edge strips"
    },
    {
      "label": "footpath width",
      "value": "1500",
      "unit": "",
      "appliesTo": "FOOTPATH"
    },
    {
      "label": "offset",
      "value": "100",
      "unit": "",
      "appliesTo": "roadway/footpath dimensions"
    },
    {
      "label": "wearing course thickness",
      "value": "50mm",
      "unit": "",
      "appliesTo": "WC"
    },
    {
      "label": "deck slope",
      "value": "2.5%",
      "unit": "",
      "appliesTo": "RCC CAST IN SITU DECK"
    },
    {
      "label": "support spacing",
      "value": "750",
      "unit": "",
      "appliesTo": "deck support layout in abutment section"
    },
    {
      "label": "abutment end segment",
      "value": "1275",
      "unit": "",
      "appliesTo": "A1/A2 abutment section"
    },
    {
      "label": "abutment support spacing",
      "value": "3500",
      "unit": "",
      "appliesTo": "A1/A2 abutment section"
    },
    {
      "label": "abutment reinforcement spacing",
      "value": "1000 — dimension shown within the A1/A2 abutment wall area",
      "unit": "",
      "appliesTo": "A1/A2 abutment wall"
    },
    {
      "label": "joint gap",
      "value": "20mm",
      "unit": "",
      "appliesTo": "central median wall joint"
    },
    {
      "label": "abutment pile spacing",
      "value": "3750",
      "unit": "",
      "appliesTo": "A1/A2 pile layout"
    },
    {
      "label": "abutment pile end spacing",
      "value": "775",
      "unit": "",
      "appliesTo": "A1/A2 pile layout"
    },
    {
      "label": "pier end segment",
      "value": "1275",
      "unit": "",
      "appliesTo": "P1 pier cap, marked (SQ)"
    },
    {
      "label": "pier cap segment",
      "value": "3500",
      "unit": "",
      "appliesTo": "P1 pier cap, marked (SQ)"
    },
    {
      "label": "pier column spacing",
      "value": "4500",
      "unit": "",
      "appliesTo": "P1 pier section"
    },
    {
      "label": "pier offset",
      "value": "1000",
      "unit": "",
      "appliesTo": "P1 pier section"
    },
    {
      "label": "pier pile spacing",
      "value": "3000",
      "unit": "",
      "appliesTo": "P1 pile layout"
    },
    {
      "label": "pier pile end spacing",
      "value": "775",
      "unit": "",
      "appliesTo": "P1 pile layout"
    },
    {
      "label": "ACTL A1 L/S",
      "value": "514.674",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "ACTL A2 L/S",
      "value": "516.136",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "ACTL A1 R/S",
      "value": "514.839",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "ACTL A2 R/S",
      "value": "516.318",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "PCTL A1 L/S",
      "value": "508.655",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "PCTL A2 L/S",
      "value": "511.391",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "PCBL A1 L/S",
      "value": "506.855",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "PCBL A2 L/S",
      "value": "509.591",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "PILE TIP LVL. A1 L/S",
      "value": "481.905",
      "unit": "",
      "appliesTo": "A1 piles"
    },
    {
      "label": "PILE TIP LVL. A2 L/S",
      "value": "484.641",
      "unit": "",
      "appliesTo": "A2 piles"
    },
    {
      "label": "PCTL A1 R/S",
      "value": "508.655",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "PCTL A2 R/S",
      "value": "511.391",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "PCBL A1 R/S",
      "value": "506.855",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "PCBL A2 R/S",
      "value": "509.591",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "PILE TIP LVL. A1 R/S",
      "value": "481.905",
      "unit": "",
      "appliesTo": "A1 piles"
    },
    {
      "label": "PILE TIP LVL. A2 R/S",
      "value": "484.641",
      "unit": "",
      "appliesTo": "A2 piles"
    },
    {
      "label": "PCTL P1 L/S",
      "value": "515.384",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "PCTL A2 R/S",
      "value": "515.567",
      "unit": "",
      "appliesTo": "lower right pier-location section"
    },
    {
      "label": "PCTL P1 L/S",
      "value": "503.316",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "PCTL P1 R/S",
      "value": "503.316",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "PCBL P1 L/S",
      "value": "501.516",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "PCBL P1 R/S",
      "value": "501.516",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "PILE TIP LVL. P1 L/S",
      "value": "476.566",
      "unit": "",
      "appliesTo": "P1 piles"
    },
    {
      "label": "PILE TIP LVL. P1 R/S",
      "value": "476.566",
      "unit": "",
      "appliesTo": "P1 piles"
    },
    {
      "label": "scale",
      "value": "1:150",
      "unit": "",
      "appliesTo": "SECTION AT ABUTMENT LOCATION AT A1 & A2"
    },
    {
      "label": "scale",
      "value": "1:150",
      "unit": "",
      "appliesTo": "SECTION AT PIER LOCATION"
    }
  ],
  "notes": [
    "50mm THK. (WC)",
    "RCC CAST IN SITU DECK SLOPE 2.5%",
    "20mm GAP FILLED WITH POLYSULPHIDE SEALANT",
    "CANTILEVER MEDIAN WALL",
    "READ THIS DRAWING IN CONJUNCTION WITH OTHER SHEETS OF THE SAME DRAWING NUMBER"
  ],
  "labels": [
    "C OF PROPOSED ROAD",
    "C OF LHS (CARRIAGEWAY)",
    "C OF RHS (CARRIAGEWAY)",
    "FRL",
    "ROW",
    "R/W",
    "SECTION AT ABUTMENT LOCATION AT A1 & A2",
    "SECTION AT PIER LOCATION",
    "NOTES:"
  ],
  "description": "This crop contains two transverse bridge sections. The upper drawing documents the A1 and A2 abutment arrangement, including roadway decks, central median wall, abutment pile caps and piles; the lower drawing documents the P1 pier arrangement with pier caps, columns, pile caps and piles. Elevation callouts are provided for the A1, A2 and P1 structural levels and pile tips."
}

p03_r02 section at abutment location at a1 a2Section

  • footpath×4rectangular stripShown adjacent to the outside crash barriers.

80000 right of way width40000 right of way half-width29000 centreline of proposed road16550 section width13500 carriageway width450 edge width1500 footpath width100 offset+41 more