Matched toGranular Filter Layerbridge.drainage_protection_system.filter_layeron “FILTER MEDIA”
| The class asks for | Value | How | From |
|---|---|---|---|
| LengthLwants m/mm | not establishedNo dimension owned by the filter media other than its thickness is given in any of the three crops. | not found | |
| WidthWwants m/mm | not establishedOnly the thickness callout '600 THK.' is dimensioned for this item; no second plan/elevation dimension exists in the readings. | not found | |
| Layer ThicknessT_layerwants m/mm | 600 mmCallout read directly: '600 THK. FILTER MEDIA'; measurement line 'Filter media thickness = 600 THK.' appliesTo 'Filter media'. Drawing note states all dimensions are in mm unless otherwise specified.Stated outright and consistently in all three crops, and explicitly attributed to the filter media. | read | p2 · p02_r07p2 · p02_r02p2 · p02_r07 section through wall abutment with bored piles |
| Material TypeMAT | Filter media (granular filter material) placed behind abutment / independent retaining wall -Callout '600 THK. FILTER MEDIA' on both the abutment section (SECTION A-A, 1:150) and the general elevation (1:300); object described as 'granular filter media'. No gradation specification or material grade is printed in the readings.The material designation is taken from the drawing's own callout; the finer classification (granular) is the annotated description, but no specification clause or gradation is given, hence the material is identified only generically. | readcheck | p2 · p02_r07p2 · p02_r02p2 · p02_r07 section through wall abutment with bored piles |
Worked out by anthropic/claude-opus-5 from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.
How the sheets named it
Every dimension read for it2
- 600 THK.Filter media thicknessp2 · p02_r07
- 600 THK.Filter media thicknessp2 · p02_r07 section through wall abutment with bored piles
Notes on the sheets that carry it
- p2POT-PTFE BEARING (TYP.)
- p2RCC SEISMIC STOPPER
- p2STONE PITCHING
- p2INDEPENDENT RETAINING WALL
- p2600 THK. FILTER MEDIA
- p21200 DIA BORED CAST-IN-SITU PILES
- p2(SCALE 1:150)
- p2NOTES:
- p21. ALL DIMENSIONS ARE IN M... OTHERWISE SPECIFIED. (text cut off at right edge)
- p22. DIMENSIONS ARE NOT TO ... FOLLOWED. (partial)
- p23. THIS DRAWING SHALL BE ... ALIGNMENT DRAWINGS. (partial)
- p24. THE BRIDGE HAS BEEN DE... CLASS 70R + TWO LANE ... 70R OR SV LOADING WHIC... (partial)
- p25. GRADE OF CONCRETE FOR ... FOLLOWS:—
- p2• PSC PRECAST GIRDER ——... (partial)
- p2• R.C.C. CAST IN SITU D... (partial)
- p2• R.C.C. END CROSS GIRDE... (partial)
- p2• R.C.C. INTERMEDIATE CROS... (partial)
- p2• BEARING PEDESTAL ——... (partial)
- p2300 THK. APPROACH SLAB
- p2150 THK. PCC LEVELING COURSE
- p2RCC CRASH BARRIER
- p2DECK CONTINUITY
- p2RCC COLUMN PIER (TYP.)
- p21200# RCC CAST IN SITU PILE (TYP.)
- p2PRECAST PSC GIRDER (TYP.)
- p2WALL TYPE ABUTMENT
- p2LAUNCHING APRON
Every crop it was read in — the drawing beside what the model took off it
Page 2
p02_r07Section
The merge put this crop under the item, but its reading names it differently — open the crop to see what it said.
1070 (SQ.) Distance from face to C/L of bearing (square)1236 (SK.) Distance from face to C/L of bearing (skew)80(SQ.) 92(SK) Expansion gap230 Deck slab thickness2650 Superstructure depth3500(SQ) Dimension at deck top (square)1500 Dimension2850 Dimension+9 more
p02_r02Elevation
- Filter media×2layergranular filter600 THK. behind retaining walls
40000(SQ) 46188(SK) Span (C/L exp. joint to C/L brg. at pier), left span46000(SK) 46188(SK) Span, right span37761(SQ) 43602(SK) C/C bearing span, left37761(SQ) 43602(SK) C/C bearing span, right80(SQ.) 92(SK) Expansion gap80(SQ.) 92(SK) Expansion gap1070(SQ) 1236(SK) C/L exp. joint to C/L of bearing1070(SQ) 1236(SK) C/L exp. joint to C/L of bearing+42 more
p02_r07 section through wall abutment with bored pilesSection
- Filter media behind abutment/wall×1vertical layergranular filter mediaCallout '600 THK. FILTER MEDIA'.
1070 (SQ.) — between C OF BRG. and C OF EXP. JOINT Distance from grid/centre of bearing (square)1236 (SK.) — between C OF BRG. and C OF EXP. JOINT Distance (skew)80(SQ.) 92(SK.) Expansion gap230 Deck slab thickness (top dimension)2650 Superstructure depth3500(SQ) Cantilever / dirt wall dimension1500 Dimension at girder web/diaphragm2850 Dimension from web to centre of bearing+9 more