Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Bearing Pedestal

1 page · 5 crops · substructure

Matched toBearing Seatbridge.substructure.bearing_seaton “Bearing pedestal”

2 read off the drawings · 3 not established
The class asks forValueHowFrom
LengthLwants m/mmnot establishedNo stated plan dimension for the pedestal; dimensions present in the elevation crop (pile cap 12300/5100, pile 1200 dia, spans, etc.) belong to other items and must not be borrowed.not found
WidthWwants m/mmnot establishedPedestal plan size would come from a pier-cap/abutment-cap bearing layout detail, which is not among these crops.not found
HeightHwants m/mm200 mmNote 16: "THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL." The pedestal height is therefore stated as 200 mm (consistent with 400 mm total − 200 mm bearing = 200 mm pedestal).Value is written in the notes as the pedestal height, but it is presented as a design assumption for fixing pier-cap top level (and Note 14 states dimensions are tentative), and it is not a dimensioned pedestal detail, so confidence is kept low.readcheckp2 · p02_r04p2 · p02_r05p2 · p02_r04 notes of general design notes and pile load tablep2 · p02_r05 general design notes 1 18 with load table
Instance CountNwants countnot establishedOnly bearing 'TYP.' callouts exist; a cross-section or bearing layout giving the number of girders/bearings per support is not in the readings.not found
Concrete GradefckM50 -Note 5, grade of concrete list: "BEARING PEDESTAL ------------M50".Stated outright against the bearing pedestal in the concrete grade schedule, repeated identically in four readings.readp2 · p02_r04p2 · p02_r05p2 · p02_r04 notes of general design notes and pile load tablep2 · p02_r05 general design notes 1 18 with load table

Worked out by anthropic/claude-opus-5 from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

How the sheets named it

Bearing pedestal · rectangular block · concrete · Shown under bearings; mentioned in cut-off notes list

Every dimension read for it9

  • M50Concrete grade - bearing pedestalp2 · p02_r04
  • 400 mmDepth of bearing & pedestal considered for piercap top levelp2 · p02_r04
  • 200 mmPedestal height for adjustmentp2 · p02_r04
  • M50Grade of concrete – bearing pedestalp2 · p02_r05
  • 200 mmPedestal height for adjustmentp2 · p02_r05
  • M50Grade of concrete – bearing pedestalp2 · p02_r04 notes of general design notes and pile load table
  • 200 mmPedestal height for adjustmentp2 · p02_r04 notes of general design notes and pile load table
  • M50Grade of concrete – bearing pedestalp2 · p02_r05 general design notes 1 18 with load table
  • 200 mmPedestal height for adjustmentp2 · p02_r05 general design notes 1 18 with load table

Notes on the sheets that carry it

  • p21. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
  • p22. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
  • p23. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
  • p24. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
  • p25. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-
  • p2PSC PRECAST GIRDER -----------M50
  • p2R.C.C. CAST IN SITU DECK SLAB ----M45
  • p2R.C.C. END CROSS GIRDER ---- ---M45
  • p2R.C.C. INTERMEDIATE CROSS GIRDER --M45
  • p2BEARING PEDESTAL ------------M50
  • p2CRASH BARRIER --------------M40
  • p2APPROACH SLAB --------------M30
  • p2LEVELLING COURSE ------------M15
  • p2DIRT WALL & SLAB ------------M35
  • p2ABUTMENT & PIER ------------M45
  • p2PILE FOUNDATION -------------M35
  • p26. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION......75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP......45mm; PIER & PIER CAP......45mm; SUPERSTRUCTURE......45mm
  • p27. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.
  • p28. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.
  • p29. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.
  • p210. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.
  • p211. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.
  • p212. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.
  • p213. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.
  • p214. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.
  • p215. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°, γ=2T/m³
  • p216. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.
  • p217. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.
  • p218. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-
  • p25. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- PSC PRECAST GIRDER -----------M50; R.C.C. CAST IN SITU DECK SLAB ----M45; R.C.C. END CROSS GIRDER ---- ---M45; R.C.C. INTERMEDIATE CROSS GIRDER --M45; BEARING PEDESTAL -------------M50; CRASH BARRIER ---------------M40; APPROACH SLAB --------------M30; LEVELLING COURSE ------------M15; DIRT WALL & SLAB ------------M35; ABUTMENT & PIER ------------M45; PILE FOUNDATION -------------M35
  • p2READ THIS DRAWING IN CONJUNCTION WITH OTHER SHEETS OF THE SAME DRAWING NUMBER
  • p2NOTES:
  • p21. ALL DIMENSIONS ARE IN [text cut off] OTHERWISE SPECIFIED.
  • p22. DIMENSIONS ARE NOT TO [text cut off] FOLLOWED.
  • p23. THIS DRAWING SHALL BE [text cut off] ALIGNMENT DRAWINGS.
  • p24. THE BRIDGE HAS BEEN [text cut off] CLASS 70R + TWO LANE[S] [cut off] 70R OR SV LOADING WH[text cut off]
  • p25. GRADE OF CONCRETE FO[R] [cut off] FOLLOWS:-
  • p2• PSC PRECAST GIRDER - [value cut off]
  • p2• R.C.C. CAST IN SITU [text cut off]
  • p2• R.C.C. END CROSS GIRD[ER] [cut off]

Every crop it was read in — the drawing beside what the model took off it

Page 2

crop

p02_r04

page 2 · general_design_notes_and_pile_load_table_p02_r04
Original
p02_r04
{
  "view": "Notes",
  "objects": [
    {
      "name": "PSC precast girder",
      "tag": "",
      "shape": "",
      "material": "prestressed precast concrete M50",
      "count": null,
      "note": "Referred to only in concrete grade list; not drawn."
    },
    {
      "name": "Cast in situ deck slab",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": "Listed in concrete grade schedule."
    },
    {
      "name": "End cross girder",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": "Listed in concrete grade schedule."
    },
    {
      "name": "Intermediate cross girder",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": "Listed in concrete grade schedule."
    },
    {
      "name": "Bearing pedestal",
      "tag": "",
      "shape": "",
      "material": "concrete M50",
      "count": null,
      "note": "200mm pedestal referenced in note 16."
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete M40",
      "count": null,
      "note": "Details to be taken from miscellaneous drawing."
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete M30",
      "count": null,
      "note": "Details to be taken from miscellaneous drawing."
    },
    {
      "name": "Levelling course",
      "tag": "",
      "shape": "",
      "material": "concrete M15",
      "count": null,
      "note": ""
    },
    {
      "name": "Dirt wall & slab",
      "tag": "",
      "shape": "",
      "material": "concrete M35",
      "count": null,
      "note": ""
    },
    {
      "name": "Abutment · concrete M45 · Cover requirement stated.",
      "tag": "",
      "shape": "",
      "material": "concrete M45",
      "count": null,
      "note": "Cover requirement stated."
    },
    {
      "name": "Pier · concrete M45 · Piercap top level fixed per note 16.",
      "tag": "",
      "shape": "",
      "material": "concrete M45",
      "count": null,
      "note": "Piercap top level fixed per note 16."
    },
    {
      "name": "Pile foundation",
      "tag": "",
      "shape": "",
      "material": "concrete M35",
      "count": null,
      "note": "Tentative working loads given in table."
    },
    {
      "name": "Reinforcement bar",
      "tag": "",
      "shape": "deformed (TMT)",
      "material": "high yield strength steel Grade Fe 550D, IS: 1786",
      "count": null,
      "note": ""
    },
    {
      "name": "Expansion joint",
      "tag": "",
      "shape": "strip seal type",
      "material": "",
      "count": null,
      "note": "As per MORTH specification."
    },
    {
      "name": "Bituminous concrete wearing course",
      "tag": "",
      "shape": "",
      "material": "bituminous concrete",
      "count": null,
      "note": "50MM thick, single layer."
    },
    {
      "name": "Drainage spout",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "To be provided in deck slab as per MORTH."
    },
    {
      "name": "Bearing",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "400mm depth of bearing & pedestal assumed."
    },
    {
      "name": "Gap slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Referenced in note 17 only."
    },
    {
      "name": "RE wall with selected earth backfill",
      "tag": "",
      "shape": "",
      "material": "selected earth fill",
      "count": null,
      "note": "Fill properties given in note 15."
    }
  ],
  "measurements": [
    {
      "label": "Concrete grade - PSC precast girder",
      "value": "M50",
      "unit": "",
      "appliesTo": "PSC precast girder"
    },
    {
      "label": "Concrete grade - R.C.C. cast in situ deck slab",
      "value": "M45",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Concrete grade - R.C.C. end cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "end cross girder"
    },
    {
      "label": "Concrete grade - R.C.C. intermediate cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "intermediate cross girder"
    },
    {
      "label": "Concrete grade - bearing pedestal",
      "value": "M50",
      "unit": "",
      "appliesTo": "bearing pedestal"
    },
    {
      "label": "Concrete grade - crash barrier",
      "value": "M40",
      "unit": "",
      "appliesTo": "crash barrier"
    },
    {
      "label": "Concrete grade - approach slab",
      "value": "M30",
      "unit": "",
      "appliesTo": "approach slab"
    },
    {
      "label": "Concrete grade - levelling course",
      "value": "M15",
      "unit": "",
      "appliesTo": "levelling course"
    },
    {
      "label": "Concrete grade - dirt wall & slab",
      "value": "M35",
      "unit": "",
      "appliesTo": "dirt wall & slab"
    },
    {
      "label": "Concrete grade - abutment & pier",
      "value": "M45",
      "unit": "",
      "appliesTo": "abutment & pier"
    },
    {
      "label": "Concrete grade - pile foundation",
      "value": "M35",
      "unit": "",
      "appliesTo": "pile foundation"
    },
    {
      "label": "Clear cover - foundation",
      "value": "75",
      "unit": "mm",
      "appliesTo": "foundation"
    },
    {
      "label": "Clear cover - abutment & abutment cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "abutment & abutment cap"
    },
    {
      "label": "Clear cover - pier & pier cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "pier & pier cap"
    },
    {
      "label": "Clear cover - superstructure",
      "value": "45",
      "unit": "mm",
      "appliesTo": "superstructure"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "reinforcement bar"
    },
    {
      "label": "Bituminous concrete thickness",
      "value": "50",
      "unit": "MM",
      "appliesTo": "bituminous concrete layer"
    },
    {
      "label": "Depth of bearing & pedestal considered for piercap top level",
      "value": "400",
      "unit": "mm",
      "appliesTo": "bearing / pedestal"
    },
    {
      "label": "Bearing height threshold",
      "value": "200",
      "unit": "mm",
      "appliesTo": "bearing"
    },
    {
      "label": "Pedestal height for adjustment",
      "value": "200",
      "unit": "mm",
      "appliesTo": "bearing pedestal"
    },
    {
      "label": "Backfill cohesion C",
      "value": "0",
      "unit": "",
      "appliesTo": "selected earth fill behind RE wall"
    },
    {
      "label": "Backfill friction angle ø",
      "value": ">32°",
      "unit": "",
      "appliesTo": "selected earth fill behind RE wall"
    },
    {
      "label": "Backfill unit weight γ",
      "value": "2",
      "unit": "T/m³",
      "appliesTo": "selected earth fill behind RE wall"
    },
    {
      "label": "MAX. VERTICAL LOAD",
      "value": "300",
      "unit": "T",
      "appliesTo": "pile (tentative working pile load)"
    },
    {
      "label": "LATERAL LOAD",
      "value": "50",
      "unit": "T",
      "appliesTo": "pile (tentative working pile load)"
    },
    {
      "label": "Seismic zone",
      "value": "III",
      "unit": "",
      "appliesTo": "structure"
    },
    {
      "label": "Wind zone",
      "value": "IV",
      "unit": "",
      "appliesTo": "structure"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "5. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-",
    "PSC PRECAST GIRDER -----------M50",
    "R.C.C. CAST IN SITU DECK SLAB ----M45",
    "R.C.C. END CROSS GIRDER ---- ---M45",
    "R.C.C. INTERMEDIATE CROSS GIRDER --M45",
    "BEARING PEDESTAL ------------M50",
    "CRASH BARRIER --------------M40",
    "APPROACH SLAB --------------M30",
    "LEVELLING COURSE ------------M15",
    "DIRT WALL & SLAB ------------M35",
    "ABUTMENT & PIER ------------M45",
    "PILE FOUNDATION -------------M35",
    "6. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION......75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP......45mm; PIER & PIER CAP......45mm; SUPERSTRUCTURE......45mm",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.",
    "8. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.",
    "9. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.",
    "10. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.",
    "11. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.",
    "12. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.",
    "13. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.",
    "14. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.",
    "15. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°, γ=2T/m³",
    "16. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.",
    "17. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.",
    "18. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-"
  ],
  "labels": [
    "NOTES:",
    "SUBSTRUCTURE",
    "SUPERSTRUCTURE",
    "FOUNDATION",
    "MAX. VERTICAL LOAD",
    "LATERAL LOAD",
    "T"
  ],
  "description": "This crop is a block of general design notes for a bridge, ending with a small two-row tentative working pile load table. It states dimensional conventions, live load design cases (IRC Class A / 70R / SV), concrete grades for each structural component, clear cover values, reinforcement grade, expansion joint and drainage spout specifications, wearing course thickness, seismic/wind zone and exposure, backfill properties behind the RE wall, and piercap/bearing pedestal level assumptions. No structural geometry is drawn here; quantities must be read from other sheets, using this crop only for material grades, covers and the stated 300 T vertical / 50 T lateral tentative pile working loads."
}

p02_r04Notes

  • Bearing pedestalconcrete M50200mm pedestal referenced in note 16.

M50 Concrete grade - PSC precast girderM45 Concrete grade - R.C.C. cast in situ deck slabM45 Concrete grade - R.C.C. end cross girderM45 Concrete grade - R.C.C. intermediate cross girderM50 Concrete grade - bearing pedestalM40 Concrete grade - crash barrierM30 Concrete grade - approach slabM15 Concrete grade - levelling course+19 more

crop

p02_r05

page 2 · general_design_notes_p02_r05
Original
p02_r05
{
  "view": "Notes",
  "objects": [
    {
      "name": "PSC precast girder",
      "tag": "",
      "shape": "",
      "material": "prestressed precast concrete M50",
      "count": null,
      "note": "referenced only in concrete grade list"
    },
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "",
      "material": "R.C.C. cast in situ M45",
      "count": null,
      "note": "grade listed; drainage spouts to be provided in deck slab"
    },
    {
      "name": "End cross girder",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": ""
    },
    {
      "name": "Intermediate cross girder",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": ""
    },
    {
      "name": "Bearing pedestal",
      "tag": "",
      "shape": "",
      "material": "concrete M50",
      "count": null,
      "note": "200mm pedestal referenced in note 16"
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete M40",
      "count": null,
      "note": ""
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete M30",
      "count": null,
      "note": ""
    },
    {
      "name": "Levelling course",
      "tag": "",
      "shape": "",
      "material": "concrete M15",
      "count": null,
      "note": ""
    },
    {
      "name": "Dirt wall & slab",
      "tag": "",
      "shape": "",
      "material": "concrete M35",
      "count": null,
      "note": ""
    },
    {
      "name": "Abutment & pier",
      "tag": "",
      "shape": "",
      "material": "concrete M45",
      "count": null,
      "note": "abutment cap and pier cap cover values also listed"
    },
    {
      "name": "Pile foundation",
      "tag": "",
      "shape": "",
      "material": "concrete M35",
      "count": null,
      "note": "tentative working pile loads tabulated in note 18"
    },
    {
      "name": "Expansion joint (strip seal type)",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "as per MORTH specification"
    },
    {
      "name": "Bituminous concrete wearing course",
      "tag": "",
      "shape": "",
      "material": "bituminous concrete",
      "count": null,
      "note": "50mm thick, single layer"
    },
    {
      "name": "Drainage spout",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "in deck slab as per MORTH specification"
    },
    {
      "name": "Reinforcement bar",
      "tag": "",
      "shape": "",
      "material": "high yield strength deformed (TMT) Fe 550D to IS:1786",
      "count": null,
      "note": ""
    },
    {
      "name": "RE wall backfill / selected earth fill",
      "tag": "",
      "shape": "",
      "material": "selected earth fill",
      "count": null,
      "note": "properties specified in note 15"
    },
    {
      "name": "Gap slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "referenced in note 17, details on miscellaneous drawing"
    },
    {
      "name": "Bearing",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "400mm depth of bearing & pedestal assumed for piercap top level"
    }
  ],
  "measurements": [
    {
      "label": "Grade of concrete – PSC precast girder",
      "value": "M50",
      "unit": "",
      "appliesTo": "PSC precast girder"
    },
    {
      "label": "Grade of concrete – R.C.C. cast in situ deck slab",
      "value": "M45",
      "unit": "",
      "appliesTo": "Deck slab"
    },
    {
      "label": "Grade of concrete – R.C.C. end cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "End cross girder"
    },
    {
      "label": "Grade of concrete – R.C.C. intermediate cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "Intermediate cross girder"
    },
    {
      "label": "Grade of concrete – bearing pedestal",
      "value": "M50",
      "unit": "",
      "appliesTo": "Bearing pedestal"
    },
    {
      "label": "Grade of concrete – crash barrier",
      "value": "M40",
      "unit": "",
      "appliesTo": "Crash barrier"
    },
    {
      "label": "Grade of concrete – approach slab",
      "value": "M30",
      "unit": "",
      "appliesTo": "Approach slab"
    },
    {
      "label": "Grade of concrete – levelling course",
      "value": "M15",
      "unit": "",
      "appliesTo": "Levelling course"
    },
    {
      "label": "Grade of concrete – dirt wall & slab",
      "value": "M35",
      "unit": "",
      "appliesTo": "Dirt wall & slab"
    },
    {
      "label": "Grade of concrete – abutment & pier",
      "value": "M45",
      "unit": "",
      "appliesTo": "Abutment & pier"
    },
    {
      "label": "Grade of concrete – pile foundation",
      "value": "M35",
      "unit": "",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Clear cover – foundation",
      "value": "75",
      "unit": "mm",
      "appliesTo": "Foundation"
    },
    {
      "label": "Clear cover – substructure, abutment & abutment cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Abutment & abutment cap"
    },
    {
      "label": "Clear cover – pier & pier cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Pier & pier cap"
    },
    {
      "label": "Clear cover – superstructure",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Superstructure"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "Reinforcement bar"
    },
    {
      "label": "Bituminous concrete thickness",
      "value": "50MM",
      "unit": "",
      "appliesTo": "Bituminous concrete wearing course"
    },
    {
      "label": "Backfill cohesion",
      "value": "C=0",
      "unit": "",
      "appliesTo": "RE wall backfill"
    },
    {
      "label": "Backfill angle of internal friction",
      "value": "Ø>32°",
      "unit": "",
      "appliesTo": "RE wall backfill"
    },
    {
      "label": "Backfill unit weight",
      "value": "γ=2",
      "unit": "T/m³",
      "appliesTo": "RE wall backfill"
    },
    {
      "label": "Depth of bearing & pedestal considered for piercap top level",
      "value": "400",
      "unit": "mm",
      "appliesTo": "Bearing pedestal / pier cap"
    },
    {
      "label": "Minimum bearing height threshold",
      "value": "200",
      "unit": "mm",
      "appliesTo": "Bearing"
    },
    {
      "label": "Pedestal height for adjustment",
      "value": "200",
      "unit": "mm",
      "appliesTo": "Bearing pedestal"
    },
    {
      "label": "Max. vertical load (tentative working pile load)",
      "value": "300",
      "unit": "T",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Lateral load (tentative working pile load)",
      "value": "50",
      "unit": "T",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Seismic zone",
      "value": "III",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Wind zone",
      "value": "IV",
      "unit": "",
      "appliesTo": "Structure"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "5. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-  PSC PRECAST GIRDER -----------M50; R.C.C. CAST IN SITU DECK SLAB ----M45; R.C.C. END CROSS GIRDER ---- ---M45; R.C.C. INTERMEDIATE CROSS GIRDER --M45; BEARING PEDESTAL -------------M50; CRASH BARRIER ---------------M40; APPROACH SLAB --------------M30; LEVELLING COURSE ------------M15; DIRT WALL & SLAB ------------M35; ABUTMENT & PIER ------------M45; PILE FOUNDATION -------------M35",
    "6. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION......75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP......45mm; PIER & PIER CAP......45mm; SUPERSTRUCTURE......45mm",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.",
    "8. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.",
    "9. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.",
    "10. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.",
    "11. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.",
    "12. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.",
    "13. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.",
    "14. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.",
    "15. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, Ø>32°, γ=2T/m³",
    "16. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.",
    "17. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.",
    "18. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-",
    "READ THIS DRAWING IN CONJUNCTION WITH OTHER SHEETS OF THE SAME DRAWING NUMBER"
  ],
  "labels": [
    "NOTES:",
    "MAX. VERTICAL LOAD",
    "LATERAL LOAD",
    "T"
  ],
  "description": "This crop is a general design notes block for a bridge, listing dimensional conventions, live load design cases (IRC Class A / 70R / SV), concrete grades for each structural component, clear cover requirements, reinforcement grade, wearing course and expansion joint specifications, seismic/wind zone and exposure classification, and backfill properties. It also contains a small table of tentative working pile loads (max. vertical 300 T, lateral 50 T) and a cross-reference to miscellaneous drawings for approach slab, gap slab, crash barrier and drainage spout details. No graphical structural views are shown; a second small NOTES box at bottom right instructs the drawing be read with other sheets of the same drawing number."
}

p02_r05Notes

  • Bearing pedestalconcrete M50200mm pedestal referenced in note 16

M50 Grade of concrete – PSC precast girderM45 Grade of concrete – R.C.C. cast in situ deck slabM45 Grade of concrete – R.C.C. end cross girderM45 Grade of concrete – R.C.C. intermediate cross girderM50 Grade of concrete – bearing pedestalM40 Grade of concrete – crash barrierM30 Grade of concrete – approach slabM15 Grade of concrete – levelling course+19 more

crop

p02_r02 elevation of bridge deck piers and abutments bridge at ch 64 412

page 2 · structural_drawings_pkg_1_9fa14effda074c9fb8ebfc78f519cc6d_p02_r02_elevation_of_bridge_deck_piers_and_abutments_bridge_at_ch_64_412
Original
p02_r02 elevation of bridge deck piers and abutments bridge at ch 64 412
{
  "view": "Elevation",
  "objects": [
    {
      "name": "Wall type abutment · rectangular wall with tapered front face · ×1 · Left abutment, marked A1; labelled 'WALL TYPE ABUTMENT' on right side",
      "tag": "A1",
      "shape": "rectangular wall with tapered front face",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Left abutment, marked A1; labelled 'WALL TYPE ABUTMENT' on right side"
    },
    {
      "name": "Wall type abutment · rectangular wall with tapered front face · ×1 · Right abutment, marked A2",
      "tag": "A2",
      "shape": "rectangular wall with tapered front face",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Right abutment, marked A2"
    },
    {
      "name": "RCC column pier",
      "tag": "P1",
      "shape": "rectangular/circular column shaft",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Labelled 'RCC COLUMN PIER (TYP.)'"
    },
    {
      "name": "Pile cap · rectangular · ×3 · One under each abutment (12300 wide) and one under pier P1 (5100 wide)",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 3,
      "note": "One under each abutment (12300 wide) and one under pier P1 (5100 wide)"
    },
    {
      "name": "Cast in situ pile · circular · reinforced concrete · 1200 dia; shown in groups under abutment caps (spacings 3600, 3600, 3600) and pier cap (3600); only elevation projection visible so true number not countable",
      "tag": "",
      "shape": "circular",
      "material": "reinforced concrete",
      "count": null,
      "note": "1200 dia; shown in groups under abutment caps (spacings 3600, 3600, 3600) and pier cap (3600); only elevation projection visible so true number not countable"
    },
    {
      "name": "Precast PSC girder",
      "tag": "",
      "shape": "I-girder",
      "material": "precast prestressed concrete",
      "count": null,
      "note": "Labelled 'PRECAST PSC GIRDER (TYP.)'; girders shown in elevation over both spans, individual count not distinguishable"
    },
    {
      "name": "Deck slab with deck continuity · flat slab · ×1 · 'DECK CONTINUITY' called out over pier P1",
      "tag": "",
      "shape": "flat slab",
      "material": "reinforced concrete",
      "count": 1,
      "note": "'DECK CONTINUITY' called out over pier P1"
    },
    {
      "name": "RCC crash barrier",
      "tag": "",
      "shape": "rectangular upstand",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Labelled over each span"
    },
    {
      "name": "POT-PTFE bearing",
      "tag": "FR / FX",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Marked FR (free) at abutments and one side of pier, FX (fixed) at pier; four callouts 'POT-PTFE BEARING (TYP.)'"
    },
    {
      "name": "Expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "C/L of exp. joint marked at both abutments with exp. gap dimension"
    },
    {
      "name": "Approach slab · rectangular slab · ×2 · 300 THK. with 150 THK. PCC levelling course beneath",
      "tag": "",
      "shape": "rectangular slab",
      "material": "reinforced concrete",
      "count": 2,
      "note": "300 THK. with 150 THK. PCC levelling course beneath"
    },
    {
      "name": "PCC levelling course",
      "tag": "",
      "shape": "layer",
      "material": "plain cement concrete",
      "count": 2,
      "note": "150 THK. under approach slab"
    },
    {
      "name": "Independent retaining wall · vertical wall · ×2 · Called out at both approaches",
      "tag": "",
      "shape": "vertical wall",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Called out at both approaches"
    },
    {
      "name": "Stone pitching on filter media",
      "tag": "",
      "shape": "sloped surface protection",
      "material": "stone",
      "count": 2,
      "note": "With 600 THK. FILTER MEDIA behind"
    },
    {
      "name": "Launching apron",
      "tag": "",
      "shape": "flat apron with toe",
      "material": "",
      "count": 2,
      "note": "Labelled at left; similar element drawn at right"
    },
    {
      "name": "Embankment / approach fill slope",
      "tag": "",
      "shape": "trapezoidal slope 1:2",
      "material": "earth fill",
      "count": 2,
      "note": "Slope indicated 2:1 hatch marks at both ends"
    },
    {
      "name": "Bearing pedestal · rectangular block · concrete · Shown under bearings; mentioned in cut-off notes list",
      "tag": "",
      "shape": "rectangular block",
      "material": "reinforced concrete",
      "count": null,
      "note": "Shown under bearings; mentioned in cut-off notes list"
    }
  ],
  "measurements": [
    {
      "label": "Span length (C/L exp. joint to C/L exp. joint), left span",
      "value": "Span length (C/L exp. joint to C/L pier), left span = 40000(SQ) 46188(SK) — on Span A1-P1",
      "unit": "",
      "appliesTo": "Span A1-P1"
    },
    {
      "label": "Span length, right span",
      "value": "Span length (C/L pier to C/L exp. joint), right span = 46000(SK) 46188(SK) — on Span P1-A2",
      "unit": "",
      "appliesTo": "Span P1-A2"
    },
    {
      "label": "Expansion gap",
      "value": "80(SQ.) 92(SK)",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "Expansion gap",
      "value": "80(SQ.) 92(SK)",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "C/L of brg. to C/L of brg. (left span)",
      "value": "37761(SQ) 43602(SK)",
      "unit": "",
      "appliesTo": "A1 to P1"
    },
    {
      "label": "C/L of brg. to C/L of brg. (right span)",
      "value": "37761(SQ) 43602(SK)",
      "unit": "",
      "appliesTo": "P1 to A2"
    },
    {
      "label": "C/L exp. joint to C/L of bearing",
      "value": "1070(SQ) 1236(SK)",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "C/L exp. joint to C/L of bearing",
      "value": "1070(SQ) 1236(SK)",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "C/L pier to C/L of bearing (left side)",
      "value": "1170(SQ) 1350(SK)",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "C/L pier to C/L of bearing (right side)",
      "value": "1170(SQ) 1350(SK)",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "Approach slab thickness",
      "value": "300",
      "unit": "THK.",
      "appliesTo": "Approach slab"
    },
    {
      "label": "PCC levelling course thickness",
      "value": "150",
      "unit": "THK.",
      "appliesTo": "PCC levelling course"
    },
    {
      "label": "Filter media thickness",
      "value": "600",
      "unit": "THK.",
      "appliesTo": "Stone pitching / retaining wall backfill"
    },
    {
      "label": "Pier cap dimension (marked at deck level over pier)",
      "value": "1500 (SK)",
      "unit": "",
      "appliesTo": "P1 deck continuity / cross girder region"
    },
    {
      "label": "Vertical clearance above HFL (minimum)",
      "value": "1200 (min)",
      "unit": "",
      "appliesTo": "Soffit to HFL"
    },
    {
      "label": "HFL",
      "value": "HFL=",
      "unit": "",
      "appliesTo": "River level - value not printed/legible"
    },
    {
      "label": "LWL",
      "value": "506.000",
      "unit": "m",
      "appliesTo": "Low water level"
    },
    {
      "label": "Pile diameter",
      "value": "1200",
      "unit": "dia (#)",
      "appliesTo": "RCC cast in situ pile (TYP.)"
    },
    {
      "label": "Pile cap edge offset",
      "value": "750",
      "unit": "",
      "appliesTo": "Abutment pile cap A1"
    },
    {
      "label": "Pile spacing",
      "value": "3600 — on Abutment pile cap A2 (3 spaces shown)",
      "unit": "",
      "appliesTo": "Abutment pile cap A1 (3 spaces)"
    },
    {
      "label": "Pile cap overall width",
      "value": "12300",
      "unit": "",
      "appliesTo": "Abutment pile cap A1"
    },
    {
      "label": "Pile cap edge offset",
      "value": "750",
      "unit": "",
      "appliesTo": "Abutment pile cap A2"
    },
    {
      "label": "Pile spacing",
      "value": "3600",
      "unit": "",
      "appliesTo": "Abutment pile cap A2 (2 spaces shown)"
    },
    {
      "label": "Pile cap overall width",
      "value": "12300",
      "unit": "",
      "appliesTo": "Abutment pile cap A2"
    },
    {
      "label": "Pile cap edge offset",
      "value": "750",
      "unit": "",
      "appliesTo": "Pier pile cap P1"
    },
    {
      "label": "Pile spacing",
      "value": "3600",
      "unit": "",
      "appliesTo": "Pier pile cap P1"
    },
    {
      "label": "Pier pile cap overall width",
      "value": "5100",
      "unit": "",
      "appliesTo": "P1"
    },
    {
      "label": "Side slope",
      "value": "2 : 1",
      "unit": "",
      "appliesTo": "Approach embankment both ends"
    },
    {
      "label": "Chainage LHS",
      "value": "64+360.197",
      "unit": "km.",
      "appliesTo": "A1"
    },
    {
      "label": "Chainage RHS",
      "value": "64+371.487",
      "unit": "km.",
      "appliesTo": "A1"
    },
    {
      "label": "Chainage LHS",
      "value": "64+406.385",
      "unit": "km.",
      "appliesTo": "P1"
    },
    {
      "label": "Chainage RHS",
      "value": "64+417.675",
      "unit": "km.",
      "appliesTo": "P1"
    },
    {
      "label": "Chainage LHS",
      "value": "64+452.573",
      "unit": "km.",
      "appliesTo": "A2"
    },
    {
      "label": "Chainage RHS",
      "value": "64+463.814",
      "unit": "km.",
      "appliesTo": "A2"
    },
    {
      "label": "FRL LHS",
      "value": "518.281",
      "unit": "m",
      "appliesTo": "A1"
    },
    {
      "label": "FRL RHS (main carriageway)",
      "value": "518.465",
      "unit": "m",
      "appliesTo": "A1"
    },
    {
      "label": "FRL LHS",
      "value": "519.033",
      "unit": "m",
      "appliesTo": "P1"
    },
    {
      "label": "FRL RHS (main carriageway)",
      "value": "519.217",
      "unit": "m",
      "appliesTo": "P1"
    },
    {
      "label": "FRL LHS",
      "value": "519.785",
      "unit": "m",
      "appliesTo": "A2"
    },
    {
      "label": "FRL RHS (main carriageway)",
      "value": "519.968",
      "unit": "m",
      "appliesTo": "A2"
    },
    {
      "label": "Ground level LHS",
      "value": "509.560",
      "unit": "m",
      "appliesTo": "A1"
    },
    {
      "label": "Ground level RHS (main carriageway)",
      "value": "509.155",
      "unit": "m",
      "appliesTo": "A1"
    },
    {
      "label": "Ground level LHS",
      "value": "503.816",
      "unit": "m",
      "appliesTo": "P1"
    },
    {
      "label": "Ground level RHS (main carriageway)",
      "value": "503.883",
      "unit": "m",
      "appliesTo": "P1"
    },
    {
      "label": "Ground level LHS",
      "value": "511.891",
      "unit": "m",
      "appliesTo": "A2"
    },
    {
      "label": "Ground level RHS (main carriageway)",
      "value": "512.668",
      "unit": "m",
      "appliesTo": "A2"
    },
    {
      "label": "Drawing scale",
      "value": "1:300",
      "unit": "",
      "appliesTo": "ELEVATION"
    }
  ],
  "notes": [
    "NOTES:",
    "1. ALL DIMENSIONS ARE IN [text cut off] OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO [text cut off] FOLLOWED.",
    "3. THIS DRAWING SHALL BE [text cut off] ALIGNMENT DRAWINGS.",
    "4. THE BRIDGE HAS BEEN [text cut off] CLASS 70R + TWO LANE[S] [cut off] 70R OR SV LOADING WH[text cut off]",
    "5. GRADE OF CONCRETE FO[R] [cut off] FOLLOWS:-",
    "• PSC PRECAST GIRDER - [value cut off]",
    "• R.C.C. CAST IN SITU [text cut off]",
    "• R.C.C. END CROSS GIRD[ER] [cut off]",
    "• R.C.C. INTERMEDIATE CR[OSS ...] [cut off]",
    "• BEARING PEDESTAL [partially cut off at bottom edge]"
  ],
  "labels": [
    "TO DEWAS",
    "TO KHANDWA",
    "C/L OF EXP. JOINT",
    "C/L OF BRG.",
    "EXP.GAP",
    "300 THK. APPROACH SLAB",
    "150 THK. PCC LEVELING COURSE",
    "RCC CRASH BARRIER",
    "DECK CONTINUITY",
    "POT-PTFE BEARING (TYP.)",
    "LAUNCHING APRON",
    "RCC COLUMN PIER (TYP.)",
    "PRECAST PSC GIRDER (TYP.)",
    "WALL TYPE ABUTMENT",
    "INDEPENDENT RETAINING WALL",
    "STONE PITCHING",
    "600 THK. FILTER MEDIA",
    "1200# RCC CAST IN SITU PILE (TYP.)",
    "HFL=",
    "LWL=506.000m",
    "FR",
    "FX",
    "CHAINAGE IN (km.)",
    "FRL. (m)",
    "GROUND LEVEL (m)",
    "MAIN CARRIAGEWAY",
    "LHS",
    "RHS",
    "ELEVATION",
    "(SCALE 1:300)",
    "A1",
    "A2",
    "P1"
  ],
  "description": "This crop is the longitudinal elevation (scale 1:300) of a two-span bridge between abutments A1 (Dewas side) and A2 (Khandwa side) with a single intermediate RCC column pier P1, spans of 40000(SQ)/46188(SK) and 46000(SK)/46188(SK), precast PSC girders with deck continuity over the pier, POT-PTFE bearings (FR free / FX fixed) and expansion joints at both abutments. It also shows the substructure and foundations — wall type abutments and pier on pile caps (12300 wide at abutments, 5100 at pier) supported on 1200 dia RCC cast-in-situ piles at 3600 spacing — together with approach works: 300 thk approach slabs on 150 thk PCC levelling course, independent retaining walls, stone pitching over 600 thk filter media, launching aprons and 2:1 embankment slopes. Below the elevation is a levels table giving chainages, FRL and existing ground levels at LHS/RHS for A1, P1 and A2, and at the right edge a partially cut-off general NOTES block covering units, loading class and concrete grades."
}

p02_r02 elevation of bridge deck piers and abutments bridge at ch 64 412Elevation

  • Bearing pedestal · rectangular block · concrete · Shown under bearings; mentioned in cut-off notes listrectangular blockreinforced concreteShown under bearings; mentioned in cut-off notes list

Span length (C/L exp. joint to C/L pier), left span = 40000(SQ) 46188(SK) — on Span A1-P1 Span length (C/L exp. joint to C/L exp. joint), left spanSpan length (C/L pier to C/L exp. joint), right span = 46000(SK) 46188(SK) — on Span P1-A2 Span length, right span80(SQ.) 92(SK) Expansion gap80(SQ.) 92(SK) Expansion gap37761(SQ) 43602(SK) C/L of brg. to C/L of brg. (left span)37761(SQ) 43602(SK) C/L of brg. to C/L of brg. (right span)1070(SQ) 1236(SK) C/L exp. joint to C/L of bearing1070(SQ) 1236(SK) C/L exp. joint to C/L of bearing+39 more

crop

p02_r04 notes of general design notes and pile load table

page 2 · structural_drawings_pkg_1_9fa14effda074c9fb8ebfc78f519cc6d_p02_r04_notes_of_general_design_notes_and_pile_load_table
Original
p02_r04 notes of general design notes and pile load table
{
  "view": "Notes",
  "objects": [
    {
      "name": "PSC precast girder",
      "tag": "",
      "shape": "not drawn (text reference)",
      "material": "precast prestressed concrete M50",
      "count": null,
      "note": "referenced only in concrete grade list"
    },
    {
      "name": "Deck slab (cast in situ)",
      "tag": "",
      "shape": "not drawn",
      "material": "R.C.C. M45",
      "count": null,
      "note": "grade list; drainage spout to be provided in deck slab"
    },
    {
      "name": "End cross girder",
      "tag": "",
      "shape": "not drawn",
      "material": "R.C.C. M45",
      "count": null,
      "note": ""
    },
    {
      "name": "Intermediate cross girder",
      "tag": "",
      "shape": "not drawn",
      "material": "R.C.C. M45",
      "count": null,
      "note": ""
    },
    {
      "name": "Bearing pedestal",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M50",
      "count": null,
      "note": "200mm pedestal referenced in note 16"
    },
    {
      "name": "Bearing",
      "tag": "",
      "shape": "not drawn",
      "material": "",
      "count": null,
      "note": "400mm depth of bearing & pedestal assumed for piercap top level"
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M40",
      "count": null,
      "note": "details on miscellaneous drawing"
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M30",
      "count": null,
      "note": ""
    },
    {
      "name": "Levelling course",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M15",
      "count": null,
      "note": ""
    },
    {
      "name": "Dirt wall & slab",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M35",
      "count": null,
      "note": ""
    },
    {
      "name": "Abutment & abutment cap · not drawn · abutment concrete M45; abutment-cap concrete grade not stated",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M45",
      "count": null,
      "note": ""
    },
    {
      "name": "Pier & pier cap · not drawn · pier concrete M45; pier-cap concrete grade not stated",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M45",
      "count": null,
      "note": ""
    },
    {
      "name": "Pile foundation",
      "tag": "",
      "shape": "not drawn",
      "material": "concrete M35",
      "count": null,
      "note": "tentative working loads tabulated"
    },
    {
      "name": "Expansion joint",
      "tag": "",
      "shape": "not drawn",
      "material": "strip seal type",
      "count": null,
      "note": "as per MORTH specification"
    },
    {
      "name": "Bituminous concrete wearing course",
      "tag": "",
      "shape": "not drawn",
      "material": "bituminous concrete",
      "count": null,
      "note": "50mm thick, single layer"
    },
    {
      "name": "Reinforcement bars",
      "tag": "",
      "shape": "deformed bars",
      "material": "high yield strength deformed (TMT) Fe 550D to IS:1786",
      "count": null,
      "note": ""
    },
    {
      "name": "Drainage spout",
      "tag": "",
      "shape": "not drawn",
      "material": "",
      "count": null,
      "note": "in deck slab as per MORTH"
    },
    {
      "name": "Gap slab",
      "tag": "",
      "shape": "not drawn",
      "material": "",
      "count": null,
      "note": "refer miscellaneous drawing"
    },
    {
      "name": "RE wall (with selected earth backfill)",
      "tag": "",
      "shape": "not drawn",
      "material": "",
      "count": null,
      "note": "backfill properties specified"
    }
  ],
  "measurements": [
    {
      "label": "Grade of concrete – PSC precast girder",
      "value": "M50",
      "unit": "",
      "appliesTo": "PSC precast girder"
    },
    {
      "label": "Grade of concrete – R.C.C. cast in situ deck slab",
      "value": "M45",
      "unit": "",
      "appliesTo": "Deck slab"
    },
    {
      "label": "Grade of concrete – R.C.C. end cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "End cross girder"
    },
    {
      "label": "Grade of concrete – R.C.C. intermediate cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "Intermediate cross girder"
    },
    {
      "label": "Grade of concrete – bearing pedestal",
      "value": "M50",
      "unit": "",
      "appliesTo": "Bearing pedestal"
    },
    {
      "label": "Grade of concrete – crash barrier",
      "value": "M40",
      "unit": "",
      "appliesTo": "Crash barrier"
    },
    {
      "label": "Grade of concrete – approach slab",
      "value": "M30",
      "unit": "",
      "appliesTo": "Approach slab"
    },
    {
      "label": "Grade of concrete – levelling course",
      "value": "M15",
      "unit": "",
      "appliesTo": "Levelling course"
    },
    {
      "label": "Grade of concrete – dirt wall & slab",
      "value": "M35",
      "unit": "",
      "appliesTo": "Dirt wall & slab"
    },
    {
      "label": "Grade of concrete – abutment & pier",
      "value": "M45",
      "unit": "",
      "appliesTo": "Abutment & pier"
    },
    {
      "label": "Grade of concrete – pile foundation",
      "value": "M35",
      "unit": "",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Clear cover – foundation",
      "value": "75",
      "unit": "mm",
      "appliesTo": "Foundation"
    },
    {
      "label": "Clear cover – abutment & abutment cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Abutment & abutment cap"
    },
    {
      "label": "Clear cover – pier & pier cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Pier & pier cap"
    },
    {
      "label": "Clear cover – superstructure",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Superstructure"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "Reinforcement bars"
    },
    {
      "label": "Bituminous concrete thickness",
      "value": "50MM",
      "unit": "mm",
      "appliesTo": "Bituminous concrete wearing course"
    },
    {
      "label": "Backfill cohesion",
      "value": "C=0",
      "unit": "",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Backfill angle of internal friction",
      "value": "φ>32°",
      "unit": "degrees",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Backfill unit weight",
      "value": "2",
      "unit": "T/m³",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Depth of bearing & pedestal considered for piercap top level",
      "value": "400",
      "unit": "mm",
      "appliesTo": "Bearing & bearing pedestal"
    },
    {
      "label": "Minimum bearing height referenced",
      "value": "Bearing-height threshold = 200 mm",
      "unit": "mm",
      "appliesTo": "Bearing"
    },
    {
      "label": "Pedestal height for adjustment",
      "value": "200",
      "unit": "mm",
      "appliesTo": "Bearing pedestal"
    },
    {
      "label": "Max. vertical load (tentative working pile load)",
      "value": "300",
      "unit": "T",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Lateral load (tentative working pile load)",
      "value": "50",
      "unit": "T",
      "appliesTo": "Pile foundation"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "5. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- PSC PRECAST GIRDER -----------M50; R.C.C. CAST IN SITU DECK SLAB ----M45; R.C.C. END CROSS GIRDER ---- ---M45; R.C.C. INTERMEDIATE CROSS GIRDER --M45; BEARING PEDESTAL ------------M50; CRASH BARRIER --------------M40; APPROACH SLAB --------------M30; LEVELLING COURSE ------------M15; DIRT WALL & SLAB ------------M35; ABUTMENT & PIER ------------M45; PILE FOUNDATION -------------M35",
    "6. CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION......75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP......45mm; PIER & PIER CAP......45mm; SUPERSTRUCTURE......45mm",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.",
    "8. STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.",
    "9. BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.",
    "10. FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.",
    "11. DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.",
    "12. BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.",
    "13. THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.",
    "14. DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.",
    "15. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ⌀>32°, γ=2T/m³",
    "16. THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.",
    "17. FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.",
    "18. TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-"
  ],
  "labels": [
    "NOTES:",
    "MAX. VERTICAL LOAD",
    "LATERAL LOAD",
    "T"
  ],
  "description": "This crop is a full-page block of general notes for a bridge drawing, enclosed in the sheet border, with no graphical construction detail. It states dimensioning conventions, live load design cases, concrete grades for each structural component, reinforcement cover and steel grade, wearing course thickness, expansion joint and drainage requirements, backfill and seismic/exposure data, and cross-references to alignment, plan-profile and miscellaneous drawings. It closes with a small table of tentative working pile loads (max. vertical 300 T, lateral 50 T), useful for specification and material take-off assumptions rather than direct quantity measurement."
}

p02_r04 notes of general design notes and pile load tableNotes

  • Bearing pedestalnot drawnconcrete M50200mm pedestal referenced in note 16

M50 Grade of concrete – PSC precast girderM45 Grade of concrete – R.C.C. cast in situ deck slabM45 Grade of concrete – R.C.C. end cross girderM45 Grade of concrete – R.C.C. intermediate cross girderM50 Grade of concrete – bearing pedestalM40 Grade of concrete – crash barrierM30 Grade of concrete – approach slabM15 Grade of concrete – levelling course+17 more

crop

p02_r05 general design notes 1 18 with load table

page 2 · structural_drawings_pkg_1_9fa14effda074c9fb8ebfc78f519cc6d_p02_r05_general_design_notes_1_18_with_load_table
Original
p02_r05 general design notes 1 18 with load table
{
  "view": "Notes",
  "objects": [
    {
      "name": "PSC precast girder",
      "tag": "",
      "shape": "",
      "material": "prestressed precast concrete M50",
      "count": null,
      "note": "referenced only in concrete grade list, not drawn"
    },
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "",
      "material": "R.C.C. cast in situ, M45",
      "count": null,
      "note": "listed in concrete grade schedule"
    },
    {
      "name": "End cross girder",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": "listed in concrete grade schedule"
    },
    {
      "name": "Intermediate cross girder",
      "tag": "",
      "shape": "",
      "material": "R.C.C. M45",
      "count": null,
      "note": "listed in concrete grade schedule"
    },
    {
      "name": "Bearing pedestal",
      "tag": "",
      "shape": "",
      "material": "concrete M50",
      "count": null,
      "note": "200mm pedestal height referenced in Note 16"
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete M40",
      "count": null,
      "note": "details to be referred from miscellaneous drawing"
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete M30",
      "count": null,
      "note": "details to be referred from miscellaneous drawing"
    },
    {
      "name": "Levelling course",
      "tag": "",
      "shape": "",
      "material": "concrete M15",
      "count": null,
      "note": ""
    },
    {
      "name": "Dirt wall & slab",
      "tag": "",
      "shape": "",
      "material": "concrete M35",
      "count": null,
      "note": ""
    },
    {
      "name": "Abutment",
      "tag": "",
      "shape": "",
      "material": "concrete M45",
      "count": null,
      "note": "abutment cap cover 45mm"
    },
    {
      "name": "Pier",
      "tag": "",
      "shape": "",
      "material": "concrete M45",
      "count": null,
      "note": "pier cap cover 45mm; pier cap top level fixed per Note 16"
    },
    {
      "name": "Pile foundation",
      "tag": "",
      "shape": "",
      "material": "concrete M35",
      "count": null,
      "note": "tentative working pile loads given in table"
    },
    {
      "name": "Reinforcement bar",
      "tag": "Fe 550D",
      "shape": "deformed (TMT)",
      "material": "high yield strength deformed steel, IS: 1786",
      "count": null,
      "note": ""
    },
    {
      "name": "Expansion joint",
      "tag": "",
      "shape": "strip seal type",
      "material": "",
      "count": null,
      "note": "as per MORTH specification"
    },
    {
      "name": "Drainage spout",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "to be provided in deck slab as per MORTH specification"
    },
    {
      "name": "Bituminous concrete wearing course",
      "tag": "",
      "shape": "",
      "material": "bituminous concrete",
      "count": null,
      "note": "50mm thick, single layer"
    },
    {
      "name": "RE wall (backfill behind)",
      "tag": "",
      "shape": "",
      "material": "selected earth fill",
      "count": null,
      "note": "fill properties stated in Note 15"
    },
    {
      "name": "Gap slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "referenced in Note 17 only"
    },
    {
      "name": "Bearing · 400mm depth of brg. & pedestal considered; bearing height less than 200mm referenced",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "400mm depth of brg. & pedestal assumed; minimum bearing height 200mm referenced"
    }
  ],
  "measurements": [
    {
      "label": "Grade of concrete – PSC precast girder",
      "value": "M50",
      "unit": "",
      "appliesTo": "PSC precast girder"
    },
    {
      "label": "Grade of concrete – R.C.C. cast in situ deck slab",
      "value": "M45",
      "unit": "",
      "appliesTo": "Deck slab"
    },
    {
      "label": "Grade of concrete – R.C.C. end cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "End cross girder"
    },
    {
      "label": "Grade of concrete – R.C.C. intermediate cross girder",
      "value": "M45",
      "unit": "",
      "appliesTo": "Intermediate cross girder"
    },
    {
      "label": "Grade of concrete – bearing pedestal",
      "value": "M50",
      "unit": "",
      "appliesTo": "Bearing pedestal"
    },
    {
      "label": "Grade of concrete – crash barrier",
      "value": "M40",
      "unit": "",
      "appliesTo": "Crash barrier"
    },
    {
      "label": "Grade of concrete – approach slab",
      "value": "M30",
      "unit": "",
      "appliesTo": "Approach slab"
    },
    {
      "label": "Grade of concrete – levelling course",
      "value": "M15",
      "unit": "",
      "appliesTo": "Levelling course"
    },
    {
      "label": "Grade of concrete – dirt wall & slab",
      "value": "M35",
      "unit": "",
      "appliesTo": "Dirt wall & slab"
    },
    {
      "label": "Grade of concrete – abutment & pier",
      "value": "M45",
      "unit": "",
      "appliesTo": "Abutment and pier"
    },
    {
      "label": "Grade of concrete – pile foundation",
      "value": "M35",
      "unit": "",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Clear cover – foundation",
      "value": "75",
      "unit": "mm",
      "appliesTo": "Foundation"
    },
    {
      "label": "Clear cover – abutment & abutment cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Abutment / abutment cap"
    },
    {
      "label": "Clear cover – pier & pier cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Pier / pier cap"
    },
    {
      "label": "Clear cover – superstructure",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Superstructure"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "Reinforcement bar"
    },
    {
      "label": "Bituminous concrete thickness",
      "value": "50MM",
      "unit": "mm",
      "appliesTo": "Bituminous concrete wearing course"
    },
    {
      "label": "Backfill cohesion",
      "value": "C=0",
      "unit": "",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Backfill angle of internal friction",
      "value": "⌀>32°",
      "unit": "degrees",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Backfill unit weight",
      "value": "γ=2",
      "unit": "T/m³",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Depth of bearing & pedestal considered for piercap top level",
      "value": "400",
      "unit": "mm",
      "appliesTo": "Pier cap / bearing / pedestal"
    },
    {
      "label": "Pedestal height for adjustment",
      "value": "200",
      "unit": "mm",
      "appliesTo": "Bearing pedestal"
    },
    {
      "label": "Max. vertical load (tentative working pile load)",
      "value": "300",
      "unit": "T",
      "appliesTo": "Pile foundation"
    },
    {
      "label": "Lateral load (tentative working pile load)",
      "value": "50",
      "unit": "T",
      "appliesTo": "Pile foundation"
    }
  ],
  "notes": [
    "ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-  PSC PRECAST GIRDER -----------M50; R.C.C. CAST IN SITU DECK SLAB ----M45; R.C.C. END CROSS GIRDER ---- ---M45; R.C.C. INTERMEDIATE CROSS GIRDER --M45; BEARING PEDESTAL -------------M50; CRASH BARRIER ---------------M40; APPROACH SLAB ---------------M30; LEVELLING COURSE -------------M15; DIRT WALL & SLAB -------------M35; ABUTMENT & PIER -------------M45; PILE FOUNDATION -------------M35",
    "CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION.....75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP......45mm; PIER & PIER CAP........45mm; SUPERSTRUCTURE......45mm",
    "ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.",
    "STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.",
    "BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.",
    "FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.",
    "DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.",
    "BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.",
    "THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.",
    "DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.",
    "THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ⌀>32°, γ=2T/m³",
    "THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.",
    "FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.",
    "TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-",
    "READ THIS DRAWING IN CONJUNCTION WITH OTHER SHEETS OF THE SAME DRAWING NUMBER"
  ],
  "labels": [
    "NOTES:",
    "MAX. VERTICAL LOAD",
    "LATERAL LOAD",
    "T"
  ],
  "description": "This crop is a full-page general notes block for a PSC girder bridge, listing dimensional conventions, design live loading, concrete grades by component, clear covers, reinforcement grade, wearing course and expansion joint requirements, seismic/wind/exposure classification and backfill properties. It also contains a small table of tentative working pile loads (max. vertical 300 T, lateral 50 T) and a secondary notes box instructing that the drawing be read with other sheets of the same drawing number. No structural geometry is drawn in this crop, so quantities must be taken from the referenced detail and miscellaneous drawings; the notes only supply material grades and cover values for the take-off."
}

p02_r05 general design notes 1 18 with load tableNotes

  • Bearing pedestalconcrete M50200mm pedestal height referenced in Note 16

M50 Grade of concrete – PSC precast girderM45 Grade of concrete – R.C.C. cast in situ deck slabM45 Grade of concrete – R.C.C. end cross girderM45 Grade of concrete – R.C.C. intermediate cross girderM50 Grade of concrete – bearing pedestalM40 Grade of concrete – crash barrierM30 Grade of concrete – approach slabM15 Grade of concrete – levelling course+16 more