Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Plain Cement Concrete

1 page · 1 crop · ×1 · material

⚠ No class in the bridge ontology fits this itemAdd a class

The ontology would need a plain cement concrete material or generic concrete class.

How the sheets named it

PCC M-15

Notes on the sheets that carry it

  • p3RCC CRASH BARRIER
  • p350mm THK. (WC)
  • p3RCC CAST IN SITU DECK
  • p3SLOPE 2.5%
  • p320mm GAP FILLED WITH POLYSULPHIDE SEALANT
  • p3CANTILEVER MEDIAN WALL
  • p3PCC M-15

Every crop it was read in — the drawing beside what the model took off it

Page 3

crop

p03_r01

page 3 · end_bent_p03_r01
Original
p03_r01
{
  "view": "Section",
  "objects": [
    {
      "name": "crash barrier",
      "tag": "",
      "shape": "profiled barrier",
      "material": "RCC",
      "count": 2,
      "note": "Shown at the outer edges of the two footpaths."
    },
    {
      "name": "footpath",
      "tag": "",
      "shape": "rectangular strip",
      "material": "",
      "count": 2,
      "note": ""
    },
    {
      "name": "wearing course",
      "tag": "WC",
      "shape": "thin sloping layer",
      "material": "",
      "count": 2,
      "note": "50mm THK. (WC) is called out on both carriageways."
    },
    {
      "name": "deck slab",
      "tag": "",
      "shape": "sloping slab",
      "material": "RCC cast in situ",
      "count": 2,
      "note": "One deck slab is shown for each carriageway."
    },
    {
      "name": "abutment",
      "tag": "A1 & A2",
      "shape": "rectangular wall",
      "material": "",
      "count": 2,
      "note": "The crop is titled as a section at abutment locations A1 and A2."
    },
    {
      "name": "pile cap",
      "tag": "PCTL / PCBL",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Top and bottom pile-cap levels are identified for A1 and A2 on both L/S and R/S."
    },
    {
      "name": "pile",
      "tag": "",
      "shape": "circular pile outlines in section",
      "material": "",
      "count": null,
      "note": "Multiple piles are shown below each pile cap; the individual pile quantity is not unambiguously countable from this crop."
    },
    {
      "name": "cantilever median wall",
      "tag": "",
      "shape": "vertical rectangular wall",
      "material": "",
      "count": 1,
      "note": "Located between the two carriageways."
    },
    {
      "name": "plain cement concrete",
      "tag": "PCC M-15",
      "shape": "rectangular hatched block",
      "material": "PCC",
      "count": 1,
      "note": "Shown below the cantilever median wall."
    }
  ],
  "measurements": [
    {
      "label": "ROW",
      "value": "80000",
      "unit": "",
      "appliesTo": "ROW"
    },
    {
      "label": "dimension",
      "value": "40000",
      "unit": "",
      "appliesTo": "left side of ROW"
    },
    {
      "label": "dimension",
      "value": "40000",
      "unit": "",
      "appliesTo": "right side of ROW"
    },
    {
      "label": "carriageway overall width",
      "value": "16550",
      "unit": "",
      "appliesTo": "LHS carriageway"
    },
    {
      "label": "carriageway overall width",
      "value": "16550",
      "unit": "",
      "appliesTo": "RHS carriageway"
    },
    {
      "label": "median width",
      "value": "2900",
      "unit": "",
      "appliesTo": "between carriageways"
    },
    {
      "label": "carriageway width",
      "value": "13500",
      "unit": "",
      "appliesTo": "LHS carriageway"
    },
    {
      "label": "carriageway width",
      "value": "13500",
      "unit": "",
      "appliesTo": "RHS carriageway"
    },
    {
      "label": "dimension",
      "value": "450",
      "unit": "",
      "appliesTo": "six edge/kerb dimensions shown"
    },
    {
      "label": "footpath width",
      "value": "1500",
      "unit": "",
      "appliesTo": "left footpath"
    },
    {
      "label": "footpath width",
      "value": "1500",
      "unit": "",
      "appliesTo": "right footpath"
    },
    {
      "label": "dimension",
      "value": "100",
      "unit": "",
      "appliesTo": "four locations shown"
    },
    {
      "label": "wearing course thickness",
      "value": "50",
      "unit": "mm",
      "appliesTo": "WC, both carriageways"
    },
    {
      "label": "deck slope",
      "value": "2.5",
      "unit": "%",
      "appliesTo": "RCC cast in situ deck, both carriageways"
    },
    {
      "label": "dimension",
      "value": "750",
      "unit": "",
      "appliesTo": "two locations shown above abutments"
    },
    {
      "label": "abutment end dimension",
      "value": "1275",
      "unit": "",
      "appliesTo": "four locations shown"
    },
    {
      "label": "abutment bay spacing",
      "value": "3500",
      "unit": "",
      "appliesTo": "eight locations shown"
    },
    {
      "label": "dimension",
      "value": "1000",
      "unit": "",
      "appliesTo": "four pile-layout spacings shown"
    },
    {
      "label": "vertical dimension",
      "value": "4000",
      "unit": "",
      "appliesTo": "both abutment walls"
    },
    {
      "label": "sealant gap",
      "value": "20",
      "unit": "mm",
      "appliesTo": "gap at cantilever median wall"
    },
    {
      "label": "pile-cap length",
      "value": "16550",
      "unit": "",
      "appliesTo": "both pile caps; dimensions shown at upper and lower pile-cap lines"
    },
    {
      "label": "pile spacing",
      "value": "3750",
      "unit": "",
      "appliesTo": "eight locations shown below pile caps"
    },
    {
      "label": "end pile spacing",
      "value": "775",
      "unit": "",
      "appliesTo": "four locations shown below pile caps"
    },
    {
      "label": "ACTL",
      "value": "514.674",
      "unit": "",
      "appliesTo": "A1 L/S"
    },
    {
      "label": "ACTL",
      "value": "516.136",
      "unit": "",
      "appliesTo": "A2 L/S"
    },
    {
      "label": "ACTL",
      "value": "514.839",
      "unit": "",
      "appliesTo": "A1 R/S"
    },
    {
      "label": "ACTL",
      "value": "516.318",
      "unit": "",
      "appliesTo": "A2 R/S"
    },
    {
      "label": "PCTL",
      "value": "508.655",
      "unit": "",
      "appliesTo": "A1 L/S and A1 R/S"
    },
    {
      "label": "PCTL",
      "value": "511.391",
      "unit": "",
      "appliesTo": "A2 L/S and A2 R/S"
    },
    {
      "label": "PCBL",
      "value": "506.855",
      "unit": "",
      "appliesTo": "A1 L/S and A1 R/S"
    },
    {
      "label": "PCBL",
      "value": "509.591",
      "unit": "",
      "appliesTo": "A2 L/S and A2 R/S"
    },
    {
      "label": "PILE TIP LVL.",
      "value": "481.905",
      "unit": "",
      "appliesTo": "A1 L/S and A1 R/S"
    },
    {
      "label": "PILE TIP LVL.",
      "value": "484.641",
      "unit": "",
      "appliesTo": "A2 L/S and A2 R/S"
    },
    {
      "label": "scale",
      "value": "1:150",
      "unit": "",
      "appliesTo": "section"
    }
  ],
  "notes": [
    "RCC CRASH BARRIER",
    "50mm THK. (WC)",
    "RCC CAST IN SITU DECK",
    "SLOPE 2.5%",
    "20mm GAP FILLED WITH POLYSULPHIDE SEALANT",
    "CANTILEVER MEDIAN WALL",
    "PCC M-15"
  ],
  "labels": [
    "80000 ROW",
    "C OF PROPOSED ROAD",
    "C OF LHS (CARRIAGEWAY)",
    "C OF RHS (CARRIAGEWAY)",
    "FRL",
    "SECTION AT ABUTMENT LOCATION AT A1 & A2",
    "(SCALE 1:150)",
    "A"
  ],
  "description": "This crop shows a transverse section titled \"SECTION AT ABUTMENT LOCATION AT A1 & A2\" for two separated carriageways. It documents the deck, footpaths and RCC crash barriers above piled abutment foundations, with a cantilever median wall and PCC M-15 block between the carriageways."
}

p03_r01Section

  • plain cement concretePCC M-15×1rectangular hatched blockPCCShown below the cantilever median wall.

80000 ROW40000 dimension40000 dimension16550 carriageway overall width16550 carriageway overall width2900 median width13500 carriageway width13500 carriageway width+26 more