Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Foundation Beam

1 page · 9 crops · ×13 · substructure
Unknown ontology domain "building". Supported: bridge, highway.

Matched toPlinth Beambuilding.substructure.plinth_beamcheckon “Foundation Beam”

This class asks for no measurements, so there is no take-off to do against it.

How the sheets named it

footing beamfoundation beam detailfoundation beam membersfoundation/block symbolFB4FB5FB1, FB2, FB3, FB5FB1FB2FB3

Every dimension read for it103

  • 400FB4 section depthp1 · p01_r10
  • 250FB4 section widthp1 · p01_r10
  • 2-Y16(ALTh.)FB4 longitudinal reinforcementp1 · p01_r10
  • Y8@150 C/CFB4 link reinforcementp1 · p01_r10
  • 450FB5 section depthp1 · p01_r10
  • 300FB5 section widthp1 · p01_r10
  • 4-Y16(ALTh.)FB5 longitudinal reinforcementp1 · p01_r10
  • Y8@150 C/CFB5 link reinforcementp1 · p01_r10
  • 600brick wall/foundation vertical dimensionnot attributedp1 · p01_r10
  • 450wall/pedestal widthnot attributedp1 · p01_r10
  • 250pedestal widthnot attributedp1 · p01_r10
  • 100 THK.P.C.C. thicknessnot attributedp1 · p01_r10
  • 75 THK.B.F.S thicknessnot attributedp1 · p01_r10
  • 1500section vertical dimensionnot attributedp1 · p01_r10
  • 1000section vertical dimensionnot attributedp1 · p01_r10
  • 800section vertical dimensionnot attributedp1 · p01_r10
  • 250FB4 section widthp1 · p01_r09
  • 400FB4 section depthp1 · p01_r09
  • 2-Y16(ALTH.)FB4 longitudinal reinforcementp1 · p01_r09
  • Y8@150 C/CFB4 stirrup reinforcementp1 · p01_r09
  • 300FB5 section widthp1 · p01_r09
  • 450FB5 section depthp1 · p01_r09
  • 4-Y16(ALTH.)FB5 longitudinal reinforcementp1 · p01_r09
  • Y8@150 C/CFB5 stirrup reinforcementp1 · p01_r09
  • 600P.L. to G.L. vertical dimensionnot attributedp1 · p01_r09
  • 1600vertical dimensionnot attributedp1 · p01_r09
  • 250wall/pile width dimensionnot attributedp1 · p01_r09
  • 450vertical dimension at wall foundationnot attributedp1 · p01_r09
  • EL (±) 0.000 ME.G.L. elevationnot attributedp1 · p01_r09
  • 500Section XX vertical dimensionnot attributedp1 · p01_r09
  • 0.000 Mpartial elevation labelnot attributedp1 · p01_r14 section through pile
  • 400beam section depthnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 250beam section widthnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 450beam section depthnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 250beam section widthnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 450beam section depthnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 250beam section widthnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 3950horizontal grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 1650horizontal grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 4500horizontal grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 225horizontal grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 3400vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 1950vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 2650vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 2965vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 4125vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 5750vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 6181vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 1237vertical grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 4903sloping grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 2554sloping grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 257sloping grid dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 3950partial adjacent-plan horizontal dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 1950partial adjacent-plan vertical dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 625partial adjacent-plan horizontal dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 2650partial adjacent-plan vertical dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • 625partial adjacent-plan vertical dimensionnot attributedp1 · p01_r16 sectional rebar detail of staircase flights
  • Y8 @ 200 C/Cdistribution reinforcementnot attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 3950grid spacing A to Cnot attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 3400grid spacing 1 to 2not attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 1950grid spacing 2 to 3not attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 2650grid spacing 3 to 4not attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 2965grid spacing 4 to 6not attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 740dimensionnot attributedp1 · p01_r25 reinforcement schedule for floor beams
  • 3950horizontal grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 1650horizontal grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 4500horizontal grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 3625horizontal grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • +225offset dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 3400vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 125offset dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 1600vertical dimensionp1 · p01_r38 1st floor beam layout
  • 1800vertical dimensionp1 · p01_r38 1st floor beam layout
  • 1950vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 2650vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 2965vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 207vertical dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 740horizontal dimensionp1 · p01_r38 1st floor beam layout
  • 1400horizontal dimensionp1 · p01_r38 1st floor beam layout
  • 552diagonal dimensionp1 · p01_r38 1st floor beam layout
  • 5578diagonal dimensionp1 · p01_r38 1st floor beam layout
  • 1525vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 1440vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 4125vertical grid spacingnot attributedp1 · p01_r38 1st floor beam layout
  • 2300horizontal dimensionp1 · p01_r38 1st floor beam layout
  • 1275horizontal dimensionp1 · p01_r38 1st floor beam layout
  • 87vertical dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 257diagonal dimensionp1 · p01_r38 1st floor beam layout
  • 226diagonal dimensionp1 · p01_r38 1st floor beam layout
  • 2554diagonal dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 4903diagonal dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 442partial dimensionnot attributedp1 · p01_r38 1st floor beam layout
  • 1625lower layout dimensionnot attributedp1 · p01_r05
  • 2125lower layout dimensionnot attributedp1 · p01_r05
  • 5350lower layout dimensionnot attributedp1 · p01_r05
  • 4123lower layout dimensionnot attributedp1 · p01_r05
  • 2057lower layout dimensionnot attributedp1 · p01_r05
  • 1232lower layout dimensionnot attributedp1 · p01_r05
  • 450+225lower layout dimensionnot attributedp1 · p01_r05
  • 450FB3 section depthp1 · p01_r16
  • 250FB3 section widthp1 · p01_r16
  • 2-Y16FB3 longitudinal reinforcementp1 · p01_r16
  • +2-Y16FB3 extra top reinforcementp1 · p01_r16

Notes on the sheets that carry it

  • p1CHAIR PROVIDED
  • p1BINDING STEEL AROUND PILE BAR
  • p1SHEAR REINF.
  • p1TOP OF TIE BEAM AT (±)0.000M E.G.L.
  • p1100 THK. P.C.C (1:4:8)
  • p175 THK. B.F.S
  • p1NOMINAL STEEL Y12@150 C/C BOTHWAY AT TOP & BOT.
  • p1CUT OFF LVL.
  • p1Y16@1500 C/C STIFFENER
  • p1Y8@150 C/C
  • p1COVER BLOCK @900 C/C
  • p1(NOT TO SCALE)
  • p12-Y16(ALTh.)
  • p12-Y16(ALTh.) +1-Y16(EXT.BOT.)
  • p12-Y16(ALTh.) +2-Y16(EXT.TOP)
  • p1Y12 @ 150 C/C
  • p1ALL DISTRIBUTION REINFORCEMENT - Y8 @ 200 C/C
  • p1GRADE OF CONCRETE - M25
  • p1HALF LANDING BEAM
  • p1(UP STANDING)
  • p1CERTIFIED THAT THE PLAN HAS BE…
  • p1ACCORDING TO THE PROVISIONS
  • p1(BUILDING) RULES, 2007.
  • p1CERTIFIED THAT I HAVE GONE THROU…
  • p1(BUILDING) RULES, 2007, AND ALSO U…
  • p1DURING AND AFTER THE CONSTRUCT…
  • p11. ALL DIMENSIONS ARE IN MILLIMETE… OTHERWISE STATED.
  • p12. ALL R.C.C. MEMBERS ARE IN M-25…
  • p13. USE Fe-550 GRADE OF STEEL CON…
  • p14. WRITTEN DIMENSIONS SHOULD BE…
  • p15. ALL FLOORS ARE WATER TIGHT.
  • p16. ALL OTHERS WORKS AS PER I.S. CO…
  • p12-Y16(ALTH.) +1-Y16(EX.BOT.)
  • p12-Y16(ALTH.) +2-Y16(EX.TOP)

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r10

page 1 · lift_pit_foundation_on_piles_p01_r10
Original
p01_r10
{
  "view": "Section",
  "objects": [
    {
      "name": "brick wall",
      "tag": "",
      "shape": "rectangular",
      "material": "brick",
      "count": 2,
      "note": "Shown above foundation in upper section."
    },
    {
      "name": "lift foundation / pile cap",
      "tag": "8-P",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": null,
      "note": "Shown in upper foundation elevation and lower sectional detail."
    },
    {
      "name": "tie beam",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in lower section at E.G.L. level."
    },
    {
      "name": "pile",
      "tag": "",
      "shape": "circular",
      "material": "",
      "count": null,
      "note": "Three piles are depicted in each of the two foundation views."
    },
    {
      "name": "plain cement concrete blinding",
      "tag": "",
      "shape": "rectangular layer",
      "material": "P.C.C. (1:4:8)",
      "count": null,
      "note": "Shown below foundation/pile-cap concrete."
    },
    {
      "name": "brick flat soling",
      "tag": "",
      "shape": "rectangular layer",
      "material": "B.F.S",
      "count": null,
      "note": "Shown below P.C.C. layer."
    },
    {
      "name": "reinforcement bar",
      "tag": "",
      "shape": "straight bars with links/stirrups",
      "material": "steel",
      "count": null,
      "note": "Reinforcement is shown for foundation, pile, tie beam, and FB4/FB5 details."
    },
    {
      "name": "footing beam",
      "tag": "FB4",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Small reinforcement detail at upper left."
    },
    {
      "name": "footing beam",
      "tag": "FB5",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Small reinforcement detail at left."
    },
    {
      "name": "beam",
      "tag": "B16",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Only a partial detail is visible at lower left."
    }
  ],
  "measurements": [
    {
      "label": "FB4 section depth",
      "value": "400",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB4 section width",
      "value": "250",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB4 longitudinal reinforcement",
      "value": "2-Y16(ALTh.)",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB4 link reinforcement",
      "value": "Y8@150 C/C",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB5 section depth",
      "value": "450",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "FB5 section width",
      "value": "300",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "FB5 longitudinal reinforcement",
      "value": "4-Y16(ALTh.)",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "FB5 link reinforcement",
      "value": "Y8@150 C/C",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "brick wall/foundation vertical dimension",
      "value": "600",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "wall/pedestal width",
      "value": "450",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "pedestal width",
      "value": "250",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "foundation vertical dimension",
      "value": "1600",
      "unit": "",
      "appliesTo": "8-P"
    },
    {
      "label": "foundation depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "8-P"
    },
    {
      "label": "P.C.C. thickness",
      "value": "100 THK.",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "B.F.S thickness",
      "value": "75 THK.",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "pile-cap top level below E.G.L.",
      "value": "600",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile top level below pile-cap top",
      "value": "1000",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "pile-cap thickness",
      "value": "100",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "ground level elevation",
      "value": "EL (±) 0.000 M",
      "unit": "",
      "appliesTo": "E.G.L."
    },
    {
      "label": "top of pile cap elevation",
      "value": "EL (-) 0.600 M",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "top of pile elevation",
      "value": "EL (-) 1.500 M",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "bottom of pile cap elevation",
      "value": "EL (-) 1.600 M",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "tie reinforcement",
      "value": "12T @ 125 mm C/C",
      "unit": "",
      "appliesTo": "8-P"
    },
    {
      "label": "tie reinforcement",
      "value": "8T @ 150 mm C/C",
      "unit": "",
      "appliesTo": "8-P"
    },
    {
      "label": "pile-cap projection",
      "value": "300 TYP.",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "tie beam depth",
      "value": "500",
      "unit": "",
      "appliesTo": "tie beam"
    },
    {
      "label": "tie beam reinforcement",
      "value": "5-Y12",
      "unit": "",
      "appliesTo": "tie beam"
    },
    {
      "label": "tie beam reinforcement",
      "value": "Y12 @150 C/C",
      "unit": "",
      "appliesTo": "tie beam"
    },
    {
      "label": "shear reinforcement",
      "value": "6L Y10 @ 130 C/C",
      "unit": "",
      "appliesTo": "tie beam"
    },
    {
      "label": "pile-cap bottom reinforcement",
      "value": "5-Y16 AT BOT.",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "side reinforcement",
      "value": "Y12@150 C/C",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "P.C.C. mix",
      "value": "(1:4:8)",
      "unit": "",
      "appliesTo": "P.C.C."
    },
    {
      "label": "section vertical dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "section vertical dimension",
      "value": "1000",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "section vertical dimension",
      "value": "800",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial beam-detail width",
      "value": "500",
      "unit": "",
      "appliesTo": "B16"
    },
    {
      "label": "partial beam-detail depth",
      "value": "300",
      "unit": "",
      "appliesTo": "B16"
    },
    {
      "label": "partial beam-detail reinforcement",
      "value": "150 C/C",
      "unit": "",
      "appliesTo": "B16"
    }
  ],
  "notes": [
    "CHAIR PROVIDED",
    "BINDING STEEL AROUND PILE BAR",
    "SHEAR REINF."
  ],
  "labels": [
    "SCALE - N.T.S.",
    "DETAIL OF FB4",
    "SCALE = 1 : 25",
    "DETAIL OF FB5",
    "P.L.",
    "G.L.",
    "E.G.L",
    "TOP OF PILE CAP",
    "TOP OF PILE",
    "BOT. OF PILE CAP",
    "FOUNDATION OF LIFT",
    "TOP OF TIE BEAM AT (±)0.000M E.G.L.",
    "CUT OFF LVL.",
    "SPAN",
    "A"
  ],
  "description": "This crop shows the lift foundation on piles, including an upper elevation/section with two brick walls and a lower sectional reinforcement detail through the pile cap and tie beam. It also contains FB4 and FB5 reinforcement-section details and a partial B16 beam detail at the left edge."
}

p01_r10Section

  • footing beamFB4×1rectangularreinforced concreteSmall reinforcement detail at upper left.
  • footing beamFB5×1rectangularreinforced concreteSmall reinforcement detail at left.

400 FB4 section depth250 FB4 section width2-Y16(ALTh.) FB4 longitudinal reinforcementY8@150 C/C FB4 link reinforcement450 FB5 section depth300 FB5 section width4-Y16(ALTh.) FB5 longitudinal reinforcementY8@150 C/C FB5 link reinforcement+30 more

crop

p01_r09

page 1 · lift_pit_foundation_p01_r09
Original
p01_r09
{
  "view": "Section",
  "objects": [
    {
      "name": "brick wall",
      "tag": "",
      "shape": "rectangular wall",
      "material": "brick",
      "count": 2,
      "note": "Two wall sections are shown above the lift foundation."
    },
    {
      "name": "tie beam",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Shown connecting the wall foundations in the foundation section."
    },
    {
      "name": "pile cap",
      "tag": "8-P",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Pile cap is shown in the foundation elevation, Section XX, and a plan fragment."
    },
    {
      "name": "pile",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": null,
      "note": "Piles are shown beneath the foundation and as a separate reinforced pile elevation at right; total quantity cannot be determined from this crop."
    },
    {
      "name": "plain cement concrete levelling course",
      "tag": "",
      "shape": "rectangular layer",
      "material": "P.C.C. (1:4:8)",
      "count": null,
      "note": "Shown below pile-cap and foundation work."
    },
    {
      "name": "brick flat soling",
      "tag": "",
      "shape": "rectangular layer",
      "material": "B.F.S",
      "count": null,
      "note": "Shown below the P.C.C. layer."
    },
    {
      "name": "reinforcement bar",
      "tag": "",
      "shape": "bar grid",
      "material": "steel",
      "count": null,
      "note": "Y12, Y16, Y10 and Y8 reinforcement callouts are shown."
    },
    {
      "name": "pile reinforcement stiffener",
      "tag": "",
      "shape": "vertical bar",
      "material": "steel",
      "count": null,
      "note": "Called out as Y16@1500 C/C STIFFNER."
    },
    {
      "name": "foundation beam detail",
      "tag": "FB4",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Small reinforcement detail at upper left."
    },
    {
      "name": "foundation beam detail",
      "tag": "FB5",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Small reinforcement detail at upper left."
    }
  ],
  "measurements": [
    {
      "label": "FB4 section width",
      "value": "250",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB4 section depth",
      "value": "400",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB4 longitudinal reinforcement",
      "value": "2-Y16(ALTH.)",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB4 stirrup reinforcement",
      "value": "Y8@150 C/C",
      "unit": "",
      "appliesTo": "FB4"
    },
    {
      "label": "FB5 section width",
      "value": "300",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "FB5 section depth",
      "value": "450",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "FB5 longitudinal reinforcement",
      "value": "4-Y16(ALTH.)",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "FB5 stirrup reinforcement",
      "value": "Y8@150 C/C",
      "unit": "",
      "appliesTo": "FB5"
    },
    {
      "label": "P.L. to G.L. vertical dimension",
      "value": "600",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical dimension",
      "value": "1600",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "wall/pile width dimension",
      "value": "250",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical dimension at wall foundation",
      "value": "450",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "tie beam reinforcement",
      "value": "12T @ 125 mm C/C",
      "unit": "",
      "appliesTo": "tie beam"
    },
    {
      "label": "tie beam reinforcement",
      "value": "8T @ 150 mm C/C",
      "unit": "",
      "appliesTo": "tie beam"
    },
    {
      "label": "foundation depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "foundation"
    },
    {
      "label": "P.C.C. thickness",
      "value": "100 THK.",
      "unit": "",
      "appliesTo": "P.C.C."
    },
    {
      "label": "B.F.S. thickness",
      "value": "75 THK.",
      "unit": "",
      "appliesTo": "B.F.S"
    },
    {
      "label": "E.G.L. elevation",
      "value": "EL (±) 0.000 M",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "top of pile cap elevation",
      "value": "EL (-) 0.600 M",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "top of pile elevation",
      "value": "EL (-) 1.500 M",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "bottom of pile cap elevation",
      "value": "EL (-) 1.600 M",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "E.G.L. to top of pile cap",
      "value": "600",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "top of pile cap to top of pile",
      "value": "1000",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "overall vertical dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": "pile cap/pile"
    },
    {
      "label": "cut off level vertical dimension",
      "value": "800",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "pile cap thickness",
      "value": "100",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile reinforcement",
      "value": "1 - Y16",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "pile reinforcement",
      "value": "6-Y16",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "pile stiffener spacing",
      "value": "Y16@1500 C/C",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "pile length, not to scale",
      "value": "7000",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "pile length, not to scale",
      "value": "1800",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "Section XX vertical dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "Section XX pile cap depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "Section XX P.C.C. thickness",
      "value": "100 THK.",
      "unit": "",
      "appliesTo": "P.C.C."
    },
    {
      "label": "Section XX B.F.S. thickness",
      "value": "75 THK.",
      "unit": "",
      "appliesTo": "B.F.S"
    },
    {
      "label": "pile cap reinforcement",
      "value": "5-Y12",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap reinforcement",
      "value": "Y12 @150C/C",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap reinforcement",
      "value": "6L - Y10 @ 130 C/C",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap reinforcement",
      "value": "Y12@150 C/C",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile reinforcement at bottom",
      "value": "5-Y16",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "typical dimension",
      "value": "300 TYP.",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "Section XX vertical dimension",
      "value": "500",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "pile cap plan end dimensions",
      "value": "375",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap plan overall length",
      "value": "1350",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap plan overall width",
      "value": "750",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap plan sloping-side dimension",
      "value": "1350",
      "unit": "",
      "appliesTo": "pile cap"
    },
    {
      "label": "pile cap plan vertical dimension",
      "value": "1169",
      "unit": "",
      "appliesTo": "pile cap"
    }
  ],
  "notes": [
    "TOP OF TIE BEAM AT (±)0.000M E.G.L.",
    "100 THK. P.C.C (1:4:8)",
    "75 THK. B.F.S",
    "CHAIR PROVIDED",
    "BINDING STEEL AROUND PILE BAR",
    "NOMINAL STEEL Y12@150 C/C BOTHWAY AT TOP & BOT."
  ],
  "labels": [
    "DETAIL OF FB4",
    "SCALE = 1 : 25",
    "DETAIL OF FB5",
    "BRICK WALL",
    "P.L.",
    "G.L.",
    "E.G.L.",
    "FOUNDATION OF LIFT",
    "SECTION AT : XX",
    "CUT OFF LVL.",
    "TOP OF PILE CAP",
    "TOP OF PILE",
    "BOT. OF PILE CAP",
    "SCALE - N.T.S.",
    "A",
    "X"
  ],
  "description": "The crop shows the lift foundation arrangement, including brick walls supported on a reinforced-concrete pile cap and piles, with P.C.C. and B.F.S. below. It includes Section XX through the pile cap, a partial pile-cap plan, reinforcement callouts, FB4/FB5 beam reinforcement details, and a separate pile elevation with cutoff and level information."
}

p01_r09Section

  • foundation beam detailFB4×1rectangularSmall reinforcement detail at upper left.
  • foundation beam detailFB5×1rectangularSmall reinforcement detail at upper left.

250 FB4 section width400 FB4 section depth2-Y16(ALTH.) FB4 longitudinal reinforcementY8@150 C/C FB4 stirrup reinforcement300 FB5 section width450 FB5 section depth4-Y16(ALTH.) FB5 longitudinal reinforcementY8@150 C/C FB5 stirrup reinforcement+39 more

crop

p01_r14 section through pile

page 1 · mkpa_techno_building_2025_job_020_structural_af7b24c3bd_76c_0009c699a5_p01_r14_section_through_pile
Original
p01_r14 section through pile
{
  "view": "Section",
  "objects": [
    {
      "name": "reinforced concrete pile",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in longitudinal section; lower portion continues through two break symbols."
    },
    {
      "name": "pile cap",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Only a partial cap/detail is visible at the top of the section; its label is cropped."
    },
    {
      "name": "longitudinal reinforcement bars",
      "tag": "6-Y16",
      "shape": "straight",
      "material": "",
      "count": 6,
      "note": "Callout is repeated at several visible locations along the pile."
    },
    {
      "name": "reinforcement bar",
      "tag": "1-Y16",
      "shape": "straight",
      "material": "",
      "count": 2,
      "note": "Two identical callouts are visible at the upper partial cap/detail."
    },
    {
      "name": "stiffener reinforcement",
      "tag": "Y16@1500 C/C STIFFENER",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown at upper and lower pile portions."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y8@150 C/C",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown in the lower pile portion."
    },
    {
      "name": "cover block",
      "tag": "COVER BLOCK @900 C/C",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown in the lower pile portion."
    },
    {
      "name": "foundation beam members",
      "tag": "FB1, FB2, FB3, FB5",
      "shape": "linear",
      "material": "",
      "count": 4,
      "note": "Partially visible in the small plan fragment below the pile section."
    }
  ],
  "measurements": [
    {
      "label": "partial elevation label",
      "value": "0.000",
      "unit": "M",
      "appliesTo": ""
    },
    {
      "label": "partial pile level callout",
      "value": "1.500",
      "unit": "M",
      "appliesTo": "pile"
    },
    {
      "label": "vertical dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": "upper pile/cap detail"
    },
    {
      "label": "vertical dimension",
      "value": "800",
      "unit": "",
      "appliesTo": "upper pile detail"
    },
    {
      "label": "vertical dimension",
      "value": "1000",
      "unit": "",
      "appliesTo": "upper pile detail"
    },
    {
      "label": "stiffener spacing",
      "value": "Y16@1500 C/C",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "vertical dimension",
      "value": "7000",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "vertical dimension",
      "value": "18000",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "vertical dimension",
      "value": "11000",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "vertical dimension",
      "value": "800",
      "unit": "",
      "appliesTo": "lower pile detail"
    },
    {
      "label": "pile width",
      "value": "450",
      "unit": "",
      "appliesTo": "pile"
    },
    {
      "label": "foundation level",
      "value": "18.000",
      "unit": "M",
      "appliesTo": "pile"
    },
    {
      "label": "plan horizontal dimension",
      "value": "3625",
      "unit": "",
      "appliesTo": "partial foundation plan"
    },
    {
      "label": "plan horizontal dimension",
      "value": "1625",
      "unit": "",
      "appliesTo": "partial foundation plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "2125",
      "unit": "",
      "appliesTo": "partial foundation plan"
    },
    {
      "label": "drawing scale",
      "value": "1 : 25",
      "unit": "",
      "appliesTo": "SECTION THROUGH PILE"
    }
  ],
  "notes": [
    "CUT OFF LVL.",
    "Y16@1500 C/C STIFFENER",
    "Y8@150 C/C",
    "COVER BLOCK @900 C/C",
    "(NOT TO SCALE)"
  ],
  "labels": [
    "SECTION THROUGH PILE",
    "SCALE = 1 : 25",
    "A",
    "F",
    "G",
    "I",
    "S1",
    "S4",
    "FB1",
    "FB2",
    "FB3",
    "FB5",
    "partial: OF PILE",
    "partial: LE CAP",
    "partial: E CAP",
    "partial: ATION LVL."
  ],
  "description": "This crop principally shows a longitudinal section through one reinforced concrete pile, including its reinforcement, stiffeners, cover blocks, cut-off level, dimensions, and partial pile-cap detail. A small, cropped foundation-plan fragment is visible below the section, with grid labels and members identified as FB1, FB2, FB3, and FB5."
}

p01_r14 section through pileSection

  • foundation beam membersFB1, FB2, FB3, FB5×4linearPartially visible in the small plan fragment below the pile section.

0.000 M partial elevation label1.500 M partial pile level callout1500 vertical dimension800 vertical dimension1000 vertical dimensionY16@1500 C/C stiffener spacing7000 vertical dimension18000 vertical dimension+8 more

crop

p01_r16 sectional rebar detail of staircase flights

page 1 · mkpa_techno_building_2025_job_020_structural_af7b24c3bd_76c_0009c699a5_p01_r16_sectional_rebar_detail_of_staircase_flights
Original
p01_r16 sectional rebar detail of staircase flights
{
  "view": "Detail",
  "objects": [
    {
      "name": "reinforced concrete beam reinforcement section",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 3,
      "note": "Three small rectangular reinforcement cross-sections are visible at the top of the crop; the leftmost related detail title is partial."
    },
    {
      "name": "stair flight",
      "tag": "",
      "shape": "stepped with sloping soffit",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in typical Section Z-Z and in part on the foundation plan."
    },
    {
      "name": "upstand beam at intermediate level",
      "tag": "B15",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "At the upper stair landing/intermediate level."
    },
    {
      "name": "beam at floor level",
      "tag": "B13",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown at the lower stair landing/floor-level junction."
    },
    {
      "name": "beam at floor level",
      "tag": "B16",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Partially visible at right edge of stair section."
    },
    {
      "name": "foundation beam",
      "tag": "FB1",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Repeated throughout the partial foundation plan."
    },
    {
      "name": "foundation beam",
      "tag": "FB2",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Repeated in the partial foundation plan."
    },
    {
      "name": "foundation beam",
      "tag": "FB4",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Located adjacent to the stair opening in the plan."
    },
    {
      "name": "foundation beam",
      "tag": "FB5",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Repeated along the right side of the partial foundation plan."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y12",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Stair and landing reinforcement, shown at 150 C/C."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y8",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Stair and landing reinforcement, shown at 150 C/C."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y16",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Longitudinal reinforcement shown in the rectangular beam reinforcement sections."
    }
  ],
  "measurements": [
    {
      "label": "beam section depth",
      "value": "400",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "beam section width",
      "value": "250",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "beam section depth",
      "value": "450",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "beam section width",
      "value": "250",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "beam section depth",
      "value": "450",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "beam section width",
      "value": "250",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "Y8"
    },
    {
      "label": "reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "Y12"
    },
    {
      "label": "horizontal dimension at intermediate level",
      "value": "500",
      "unit": "",
      "appliesTo": "B15"
    },
    {
      "label": "horizontal dimension at intermediate level",
      "value": "1200",
      "unit": "",
      "appliesTo": "B15"
    },
    {
      "label": "vertical dimension at intermediate level",
      "value": "450",
      "unit": "",
      "appliesTo": "B15"
    },
    {
      "label": "beam/slab thickness",
      "value": "150",
      "unit": "",
      "appliesTo": "B15"
    },
    {
      "label": "stair flight dimension",
      "value": "1200",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "stair flight dimension",
      "value": "300",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "floor-level horizontal dimension",
      "value": "1400",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "floor-level horizontal dimension",
      "value": "300",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "beam/slab thickness",
      "value": "450",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "floor-level horizontal dimension",
      "value": "1150",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "beam width",
      "value": "250",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "horizontal grid dimension",
      "value": "3950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal grid dimension",
      "value": "1650",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal grid dimension",
      "value": "4500",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal grid dimension",
      "value": "225",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "3400",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "1950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "2650",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "2965",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "4125",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "5750",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "6181",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid dimension",
      "value": "1237",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "stair opening dimension",
      "value": "740",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "stair opening dimension",
      "value": "1400",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "sloping grid dimension",
      "value": "4903",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "sloping grid dimension",
      "value": "2554",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "sloping grid dimension",
      "value": "257",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial adjacent-plan horizontal dimension",
      "value": "3950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial adjacent-plan vertical dimension",
      "value": "1950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial adjacent-plan horizontal dimension",
      "value": "625",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial adjacent-plan vertical dimension",
      "value": "2650",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial adjacent-plan vertical dimension",
      "value": "625",
      "unit": "",
      "appliesTo": ""
    }
  ],
  "notes": [
    "2-Y16(ALTh.)",
    "Y8@150 C/C",
    "2-Y16(ALTh.) +1-Y16(EXT.BOT.)",
    "2-Y16(ALTh.) +2-Y16(EXT.TOP)",
    "Y12 @ 150 C/C",
    "Y8 @ 150 C/C"
  ],
  "labels": [
    "SPAN",
    "SUPPORT",
    "SPAN",
    "DETAIL OF TB3",
    "SCALE = 1 : 25",
    "DETAIL OF FB3",
    "SCALE = 1 : 25",
    "INTERMEDIATE LEVEL",
    "FLOOR LEVEL",
    "TYPICAL SECTIONAL DETAILS OF STAIR",
    "NOT TO SCALE",
    "SECTION: Z-Z",
    "LANDING BEAM",
    "N",
    "Z",
    "A",
    "C",
    "D",
    "E'",
    "F",
    "F'",
    "I",
    "2",
    "3",
    "7",
    "8",
    "9'",
    "SI",
    "S2",
    "S4"
  ],
  "description": "The upper portion of the crop shows typical sectional details of a reinforced-concrete stair, including an upstand beam B15 at intermediate level and beams B13 and B16 at floor level, with Y12 and Y8 reinforcement callouts. The lower portion is a partial foundation/structural plan showing repeated foundation beams FB1, FB2, FB4 and FB5, a stair opening, grid references, and a north arrow. Small beam reinforcement cross-section details, including DETAIL OF TB3 and DETAIL OF FB3, are visible along the top edge."
}

p01_r16 sectional rebar detail of staircase flightsDetail

  • foundation beamFB1linearRepeated throughout the partial foundation plan.
  • foundation beamFB2linearRepeated in the partial foundation plan.
  • foundation beamFB4×1linearLocated adjacent to the stair opening in the plan.
  • foundation beamFB5linearRepeated along the right side of the partial foundation plan.

400 beam section depth250 beam section width450 beam section depth250 beam section width450 beam section depth250 beam section width150 C/C reinforcement spacing150 C/C reinforcement spacing+33 more

crop

p01_r25 reinforcement schedule for floor beams

page 1 · mkpa_techno_building_2025_job_020_structural_af7b24c3bd_76c_0009c699a5_p01_r25_reinforcement_schedule_for_floor_beams
Original
p01_r25 reinforcement schedule for floor beams
{
  "view": "Schedule",
  "objects": [
    {
      "name": "slab panel",
      "tag": "S1",
      "shape": "rectangular",
      "material": "",
      "count": 5,
      "note": "Marked in the partial plan and scheduled."
    },
    {
      "name": "slab panel",
      "tag": "S2",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Listed in slab schedule only."
    },
    {
      "name": "slab panel",
      "tag": "S3",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Listed in slab schedule only."
    },
    {
      "name": "slab panel",
      "tag": "S4",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Marked in the partial plan and scheduled."
    },
    {
      "name": "pile cap",
      "tag": "2P",
      "shape": "rectangular",
      "material": "concrete, grade M25",
      "count": null,
      "note": "Listed in pile cap schedule."
    },
    {
      "name": "pile cap",
      "tag": "3P",
      "shape": "",
      "material": "concrete, grade M25",
      "count": null,
      "note": "Size stated as AS/DRG."
    },
    {
      "name": "pile cap",
      "tag": "4P",
      "shape": "rectangular",
      "material": "concrete, grade M25",
      "count": null,
      "note": "Listed in pile cap schedule."
    },
    {
      "name": "pile cap",
      "tag": "6P",
      "shape": "rectangular",
      "material": "concrete, grade M25",
      "count": null,
      "note": "Listed in pile cap schedule."
    },
    {
      "name": "pile cap",
      "tag": "8P",
      "shape": "rectangular",
      "material": "concrete, grade M25",
      "count": null,
      "note": "Schedule row is partially cut off at bottom of crop."
    },
    {
      "name": "foundation beam",
      "tag": "FB1",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown in partial plan."
    },
    {
      "name": "foundation beam",
      "tag": "FB2",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown in partial plan."
    },
    {
      "name": "foundation beam",
      "tag": "FB4",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown in partial plan."
    },
    {
      "name": "half landing beam",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Shown in partial plan."
    },
    {
      "name": "reinforcement bar",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Reinforcement is specified in the slab and pile cap schedules."
    }
  ],
  "measurements": [
    {
      "label": "S1 thickness",
      "value": "125",
      "unit": "MM",
      "appliesTo": "S1"
    },
    {
      "label": "S1 reinforcement at support, top",
      "value": "Y8 @ 125 C/C",
      "unit": "",
      "appliesTo": "S1"
    },
    {
      "label": "S1 reinforcement at support, bottom",
      "value": "Y8 @ 125 C/C",
      "unit": "",
      "appliesTo": "S1"
    },
    {
      "label": "S1 reinforcement at span, bottom",
      "value": "Y8 @ 125 C/C",
      "unit": "",
      "appliesTo": "S1"
    },
    {
      "label": "S2 thickness",
      "value": "150",
      "unit": "MM",
      "appliesTo": "S2"
    },
    {
      "label": "S2 reinforcement at support, top",
      "value": "Y10 @ 125 C/C",
      "unit": "",
      "appliesTo": "S2"
    },
    {
      "label": "S2 reinforcement at support, bottom",
      "value": "Y10 @ 125 C/C",
      "unit": "",
      "appliesTo": "S2"
    },
    {
      "label": "S2 reinforcement at span, bottom",
      "value": "Y10 @ 125 C/C",
      "unit": "",
      "appliesTo": "S2"
    },
    {
      "label": "S3 thickness",
      "value": "125",
      "unit": "MM",
      "appliesTo": "S3"
    },
    {
      "label": "S3 reinforcement at support, top",
      "value": "Y8 @ 150 C/C",
      "unit": "",
      "appliesTo": "S3"
    },
    {
      "label": "S3 reinforcement at support, bottom",
      "value": "Y8 @ 150 C/C",
      "unit": "",
      "appliesTo": "S3"
    },
    {
      "label": "S3 reinforcement at span, bottom",
      "value": "Y8 @ 150 C/C",
      "unit": "",
      "appliesTo": "S3"
    },
    {
      "label": "S4 thickness",
      "value": "125",
      "unit": "MM",
      "appliesTo": "S4"
    },
    {
      "label": "S4 reinforcement at support, top",
      "value": "Y8 @ 150 C/C",
      "unit": "",
      "appliesTo": "S4"
    },
    {
      "label": "S4 reinforcement at support, bottom",
      "value": "Y8 @ 150 C/C",
      "unit": "",
      "appliesTo": "S4"
    },
    {
      "label": "S4 reinforcement at span, bottom",
      "value": "Y8 @ 150 C/C",
      "unit": "",
      "appliesTo": "S4"
    },
    {
      "label": "distribution reinforcement",
      "value": "Y8 @ 200 C/C",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "2P size",
      "value": "2100 X 750",
      "unit": "",
      "appliesTo": "2P"
    },
    {
      "label": "2P depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "2P"
    },
    {
      "label": "2P reinforcement in shorter direction",
      "value": "4L-Y10 @ 150 C/C",
      "unit": "",
      "appliesTo": "2P"
    },
    {
      "label": "2P reinforcement in longer direction, top",
      "value": "Y12 @ 150 C/C (TOP)",
      "unit": "",
      "appliesTo": "2P"
    },
    {
      "label": "2P reinforcement in longer direction, bottom",
      "value": "Y12 @ 150 C/C (BOT.)",
      "unit": "",
      "appliesTo": "2P"
    },
    {
      "label": "3P depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "3P"
    },
    {
      "label": "3P reinforcement in shorter direction, top",
      "value": "Y10 @ 130 C/C (TOP)",
      "unit": "",
      "appliesTo": "3P"
    },
    {
      "label": "3P reinforcement in shorter direction, bottom",
      "value": "Y10 @ 130 C/C (BOT.)",
      "unit": "",
      "appliesTo": "3P"
    },
    {
      "label": "3P reinforcement in longer direction, top",
      "value": "Y12 @ 150 C/C (TOP)",
      "unit": "",
      "appliesTo": "3P"
    },
    {
      "label": "3P reinforcement in longer direction, bottom",
      "value": "Y12 @ 150 C/C (BOT.)",
      "unit": "",
      "appliesTo": "3P"
    },
    {
      "label": "4P size",
      "value": "2100 X 2100",
      "unit": "",
      "appliesTo": "4P"
    },
    {
      "label": "4P depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "4P"
    },
    {
      "label": "4P reinforcement in shorter direction, top",
      "value": "Y12 @ 125 C/C (TOP)",
      "unit": "",
      "appliesTo": "4P"
    },
    {
      "label": "4P reinforcement in shorter direction, bottom",
      "value": "Y16 @ 125 C/C (BOT.)",
      "unit": "",
      "appliesTo": "4P"
    },
    {
      "label": "4P reinforcement in longer direction, top",
      "value": "Y12 @ 125 C/C (TOP)",
      "unit": "",
      "appliesTo": "4P"
    },
    {
      "label": "4P reinforcement in longer direction, bottom",
      "value": "Y16 @ 125 C/C (BOT.)",
      "unit": "",
      "appliesTo": "4P"
    },
    {
      "label": "6P size",
      "value": "3450 X 2100",
      "unit": "",
      "appliesTo": "6P"
    },
    {
      "label": "6P depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "6P"
    },
    {
      "label": "6P reinforcement in shorter direction, top",
      "value": "Y16 @ 150 C/C (TOP)",
      "unit": "",
      "appliesTo": "6P"
    },
    {
      "label": "6P reinforcement in shorter direction, bottom",
      "value": "Y20 @ 150 C/C (BOT.)",
      "unit": "",
      "appliesTo": "6P"
    },
    {
      "label": "6P reinforcement in longer direction, top",
      "value": "Y16 @ 150 C/C (TOP)",
      "unit": "",
      "appliesTo": "6P"
    },
    {
      "label": "6P reinforcement in longer direction, bottom",
      "value": "Y20 @ 150 C/C (BOT.)",
      "unit": "",
      "appliesTo": "6P"
    },
    {
      "label": "8P size",
      "value": "3450 X 3088",
      "unit": "",
      "appliesTo": "8P"
    },
    {
      "label": "8P depth",
      "value": "1000",
      "unit": "",
      "appliesTo": "8P"
    },
    {
      "label": "8P reinforcement in shorter direction, top",
      "value": "Y20 @ 150 C/C (TOP)",
      "unit": "",
      "appliesTo": "8P"
    },
    {
      "label": "8P reinforcement in shorter direction, bottom",
      "value": "Y20 @ 150 C/C (BOT.)",
      "unit": "",
      "appliesTo": "8P"
    },
    {
      "label": "8P reinforcement in longer direction, top",
      "value": "Y20 @ 150 C/C (TOP)",
      "unit": "",
      "appliesTo": "8P"
    },
    {
      "label": "8P reinforcement in longer direction, bottom",
      "value": "Y20 @ 150 C/C (BOT.)",
      "unit": "",
      "appliesTo": "8P"
    },
    {
      "label": "grid spacing A to C",
      "value": "3950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "grid spacing 1 to 2",
      "value": "3400",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "grid spacing 2 to 3",
      "value": "1950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "grid spacing 3 to 4",
      "value": "2650",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "grid spacing 4 to 6",
      "value": "2965",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "dimension",
      "value": "740",
      "unit": "",
      "appliesTo": ""
    }
  ],
  "notes": [
    "ALL DISTRIBUTION REINFORCEMENT - Y8 @ 200 C/C",
    "GRADE OF CONCRETE - M25"
  ],
  "labels": [
    "SCHEDULE OF SLAB",
    "PANEL MKD.",
    "THICKNESS (MM)",
    "AT SUPPORT",
    "AT SPAN",
    "TOP",
    "BOTTOM",
    "PILE CAP SCHEDULE",
    "MKD.",
    "SIZE",
    "DEPTH",
    "REINFORCEMENT IN SHORTER DIRECTION",
    "REINFORCEMENT IN LONGER DIRECTION",
    "AS/DRG.",
    "A",
    "C",
    "1",
    "2",
    "3",
    "4",
    "6",
    "N"
  ],
  "description": "The crop primarily shows a Schedule of Slab and a Pile Cap Schedule, including slab thicknesses and reinforcement requirements and pile-cap sizes, depths, and reinforcement. At right, a partial foundation/slab plan is visible between grid lines A and C, showing FB1, FB2, FB4, slab panel marks, and a half landing beam; the plan is cropped and does not show the complete work."
}

p01_r25 reinforcement schedule for floor beamsSchedule

  • foundation beamFB1rectangularShown in partial plan.
  • foundation beamFB2rectangularShown in partial plan.
  • foundation beamFB4rectangularShown in partial plan.

125 MM S1 thicknessY8 @ 125 C/C S1 reinforcement at support, topY8 @ 125 C/C S1 reinforcement at support, bottomY8 @ 125 C/C S1 reinforcement at span, bottom150 MM S2 thicknessY10 @ 125 C/C S2 reinforcement at support, topY10 @ 125 C/C S2 reinforcement at support, bottomY10 @ 125 C/C S2 reinforcement at span, bottom+43 more

crop

p01_r38 1st floor beam layout

page 1 · mkpa_techno_building_2025_job_020_structural_af7b24c3bd_76c_0009c699a5_p01_r38_1st_floor_beam_layout
Original
p01_r38 1st floor beam layout
{
  "view": "Plan",
  "objects": [
    {
      "name": "foundation beam",
      "tag": "FB1",
      "shape": "straight and angled linear beam runs",
      "material": "",
      "count": null,
      "note": "FB1 is shown along horizontal, vertical and diagonal foundation/beam lines."
    },
    {
      "name": "foundation beam",
      "tag": "FB2",
      "shape": "straight linear beam runs",
      "material": "",
      "count": null,
      "note": ""
    },
    {
      "name": "foundation beam",
      "tag": "FB4",
      "shape": "straight rectangular beam runs",
      "material": "",
      "count": null,
      "note": ""
    },
    {
      "name": "foundation beam",
      "tag": "FB5",
      "shape": "straight vertical beam run",
      "material": "",
      "count": null,
      "note": ""
    },
    {
      "name": "filled square support/column symbol",
      "tag": "",
      "shape": "square or rectangular",
      "material": "",
      "count": 18,
      "note": "Filled dark support symbols occur at grid and diagonal-line intersections."
    },
    {
      "name": "slab area",
      "tag": "S1",
      "shape": "rectangular and irregular plan areas",
      "material": "",
      "count": null,
      "note": "Circled S1 designations are shown in multiple areas."
    },
    {
      "name": "slab area",
      "tag": "S2",
      "shape": "rectangular plan area",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "slab area",
      "tag": "S3",
      "shape": "rectangular and irregular plan areas",
      "material": "",
      "count": null,
      "note": "Circled S3 designations are shown in several locations."
    },
    {
      "name": "slab area",
      "tag": "S4",
      "shape": "rectangular plan areas",
      "material": "",
      "count": 2,
      "note": ""
    },
    {
      "name": "half landing beam",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Shown as a closely spaced lined rectangular area."
    }
  ],
  "measurements": [
    {
      "label": "horizontal grid spacing",
      "value": "3950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal grid spacing",
      "value": "1650",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal grid spacing",
      "value": "4500",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal grid spacing",
      "value": "3625",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "offset dimension",
      "value": "+225",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid spacing",
      "value": "3400",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "offset dimension",
      "value": "125",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical dimension",
      "value": "1600",
      "unit": "",
      "appliesTo": "FB2"
    },
    {
      "label": "vertical dimension",
      "value": "1800",
      "unit": "",
      "appliesTo": "FB2"
    },
    {
      "label": "vertical grid spacing",
      "value": "1950",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid spacing",
      "value": "2650",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid spacing",
      "value": "2965",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical dimension",
      "value": "207",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal dimension",
      "value": "740",
      "unit": "",
      "appliesTo": "FB1"
    },
    {
      "label": "horizontal dimension",
      "value": "1400",
      "unit": "",
      "appliesTo": "FB2"
    },
    {
      "label": "diagonal dimension",
      "value": "552",
      "unit": "",
      "appliesTo": "FB1"
    },
    {
      "label": "diagonal dimension",
      "value": "5578",
      "unit": "",
      "appliesTo": "FB1"
    },
    {
      "label": "vertical grid spacing",
      "value": "1525",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid spacing",
      "value": "1440",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "vertical grid spacing",
      "value": "4125",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal dimension",
      "value": "2300",
      "unit": "",
      "appliesTo": "FB2"
    },
    {
      "label": "horizontal dimension",
      "value": "1275",
      "unit": "",
      "appliesTo": "FB2"
    },
    {
      "label": "vertical dimension",
      "value": "87",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "diagonal dimension",
      "value": "257",
      "unit": "",
      "appliesTo": "FB1"
    },
    {
      "label": "diagonal dimension",
      "value": "226",
      "unit": "",
      "appliesTo": "FB1"
    },
    {
      "label": "diagonal dimension",
      "value": "2554",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "diagonal dimension",
      "value": "4903",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "partial dimension",
      "value": "442",
      "unit": "",
      "appliesTo": ""
    }
  ],
  "notes": [
    "HALF LANDING BEAM",
    "(UP STANDING)"
  ],
  "labels": [
    "A",
    "C",
    "D",
    "F",
    "E'",
    "F'",
    "I",
    "1",
    "2",
    "3",
    "4",
    "5",
    "6",
    "7",
    "8",
    "9",
    "9'",
    "N"
  ],
  "description": "This crop is a partial structural foundation/beam layout plan on grids A, C, D and F, with numbered horizontal grid lines and additional angled grid geometry at the lower right. It shows beam runs identified as FB1, FB2, FB4 and FB5, filled support symbols, slab-area designations, and a half landing beam area; the drawing is cropped and does not show the full plan."
}

p01_r38 1st floor beam layoutPlan

  • foundation beamFB1straight and angled linear beam runsFB1 is shown along horizontal, vertical and diagonal foundation/beam lines.
  • foundation beamFB2straight linear beam runs
  • foundation beamFB4straight rectangular beam runs
  • foundation beamFB5straight vertical beam run

3950 horizontal grid spacing1650 horizontal grid spacing4500 horizontal grid spacing3625 horizontal grid spacing+225 offset dimension3400 vertical grid spacing125 offset dimension1600 vertical dimension+20 more

crop

p01_r39 2nd floor beam layout

page 1 · mkpa_techno_building_2025_job_020_structural_af7b24c3bd_76c_0009c699a5_p01_r39_2nd_floor_beam_layout
Original
p01_r39 2nd floor beam layout
{
  "view": "Plan",
  "objects": [
    {
      "name": "foundation beam",
      "tag": "FB1",
      "shape": "linear rectangular beam runs",
      "material": "",
      "count": null,
      "note": "Repeated throughout the crop; count not stated and some runs continue beyond the crop."
    },
    {
      "name": "foundation beam",
      "tag": "FB2",
      "shape": "linear rectangular beam runs",
      "material": "",
      "count": null,
      "note": "Visible as internal and perimeter beam runs."
    },
    {
      "name": "foundation beam",
      "tag": "FB3",
      "shape": "linear rectangular beam runs",
      "material": "",
      "count": null,
      "note": "Visible at the upper-right and along the right-side vertical run."
    },
    {
      "name": "foundation beam",
      "tag": "FB4",
      "shape": "linear rectangular beam runs, including angled runs",
      "material": "",
      "count": null,
      "note": "Visible at internal, lower-left, and angled portions."
    },
    {
      "name": "foundation beam",
      "tag": "FB5",
      "shape": "linear rectangular beam runs",
      "material": "",
      "count": null,
      "note": "Visible adjacent to the central-right area."
    },
    {
      "name": "slab/panel area",
      "tag": "S1",
      "shape": "rectangular and irregular enclosed areas",
      "material": "",
      "count": null,
      "note": "Repeated circled S1 marks identify multiple areas."
    },
    {
      "name": "slab/panel area",
      "tag": "S2",
      "shape": "irregular enclosed area",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "slab/panel area",
      "tag": "S3",
      "shape": "irregular enclosed areas",
      "material": "",
      "count": null,
      "note": "Multiple circled S3 marks are visible, including at the lower angled portion."
    },
    {
      "name": "slab/panel area",
      "tag": "S4",
      "shape": "rectangular enclosed areas",
      "material": "",
      "count": null,
      "note": "Multiple circled S4 marks are visible."
    },
    {
      "name": "filled square support symbol",
      "tag": "",
      "shape": "square",
      "material": "",
      "count": null,
      "note": "Repeated solid square symbols occur at beam intersections and along the angled beam line; no element tag is printed beside them."
    },
    {
      "name": "half landing beam",
      "tag": "",
      "shape": "rectangular hatched beam area",
      "material": "",
      "count": 1,
      "note": "Shown at the left-centre of the crop and labelled HALF LANDING BEAM."
    }
  ],
  "measurements": [
    {
      "label": "horizontal grid spacing",
      "value": "3950",
      "unit": "",
      "appliesTo": "between grids A and C"
    },
    {
      "label": "horizontal grid spacing",
      "value": "1650",
      "unit": "",
      "appliesTo": "between grids C and D"
    },
    {
      "label": "horizontal grid spacing",
      "value": "4500",
      "unit": "",
      "appliesTo": "between grids D and F"
    },
    {
      "label": "horizontal grid spacing",
      "value": "3625",
      "unit": "",
      "appliesTo": "between grids F and G"
    },
    {
      "label": "horizontal dimension",
      "value": "1625",
      "unit": "",
      "appliesTo": "right of grid G"
    },
    {
      "label": "vertical grid spacing",
      "value": "3400",
      "unit": "",
      "appliesTo": "between grids 1 and 2"
    },
    {
      "label": "vertical grid spacing",
      "value": "1950",
      "unit": "",
      "appliesTo": "between grids 2 and 3"
    },
    {
      "label": "vertical grid spacing",
      "value": "2650",
      "unit": "",
      "appliesTo": "between grids 3 and 4"
    },
    {
      "label": "vertical dimension",
      "value": "29965",
      "unit": "",
      "appliesTo": "left-side vertical dimension line"
    },
    {
      "label": "vertical grid spacing",
      "value": "4125",
      "unit": "",
      "appliesTo": "between grids 4 and 6"
    },
    {
      "label": "vertical dimension",
      "value": "3215",
      "unit": "",
      "appliesTo": "upper-right vertical dimension line"
    },
    {
      "label": "vertical dimension",
      "value": "5350",
      "unit": "",
      "appliesTo": "right-side vertical dimension line"
    },
    {
      "label": "vertical dimension",
      "value": "2225",
      "unit": "",
      "appliesTo": "right-side vertical dimension line"
    },
    {
      "label": "horizontal dimension",
      "value": "1400",
      "unit": "",
      "appliesTo": "right-side internal horizontal dimension"
    },
    {
      "label": "horizontal dimension",
      "value": "225",
      "unit": "",
      "appliesTo": "right-side internal horizontal dimension"
    },
    {
      "label": "vertical dimension",
      "value": "2525",
      "unit": "",
      "appliesTo": "central-right internal vertical dimension"
    },
    {
      "label": "horizontal dimension",
      "value": "1675",
      "unit": "",
      "appliesTo": "between the central vertical beam line and internal vertical beam line"
    },
    {
      "label": "horizontal dimension",
      "value": "1950",
      "unit": "",
      "appliesTo": "between internal vertical beam line and grid G"
    },
    {
      "label": "horizontal dimension",
      "value": "625",
      "unit": "",
      "appliesTo": "near grid C at the half landing beam"
    },
    {
      "label": "horizontal dimension",
      "value": "1400",
      "unit": "",
      "appliesTo": "near grid D at the half landing beam"
    },
    {
      "label": "vertical dimension",
      "value": "4123",
      "unit": "",
      "appliesTo": "right-side vertical dimension line"
    },
    {
      "label": "vertical dimension",
      "value": "2057",
      "unit": "",
      "appliesTo": "right-side vertical dimension line"
    },
    {
      "label": "vertical dimension",
      "value": "1237",
      "unit": "",
      "appliesTo": "right-side lower vertical dimension line"
    },
    {
      "label": "diagonal dimension",
      "value": "1709",
      "unit": "",
      "appliesTo": "angled FB1/FB4 portion"
    },
    {
      "label": "diagonal dimension",
      "value": "4143",
      "unit": "",
      "appliesTo": "angled FB1/FB4 portion"
    },
    {
      "label": "diagonal dimension",
      "value": "2554",
      "unit": "",
      "appliesTo": "lower angled portion"
    }
  ],
  "notes": [],
  "labels": [
    "A",
    "C",
    "D",
    "F",
    "G",
    "1",
    "2",
    "3",
    "4",
    "6",
    "E'",
    "F'",
    "G'",
    "HALF LANDING BEAM",
    "N"
  ],
  "description": "This crop is a partial structural foundation/beam layout plan on lettered and numbered grid lines. It shows tagged FB beam runs enclosing areas marked S1 through S4, with a hatched half landing beam at the left-centre and angled beam geometry at the lower-right."
}

p01_r39 2nd floor beam layoutPlan

  • foundation beamFB1linear rectangular beam runsRepeated throughout the crop; count not stated and some runs continue beyond the crop.
  • foundation beamFB2linear rectangular beam runsVisible as internal and perimeter beam runs.
  • foundation beamFB3linear rectangular beam runsVisible at the upper-right and along the right-side vertical run.
  • foundation beamFB4linear rectangular beam runs, including angled runsVisible at internal, lower-left, and angled portions.
  • foundation beamFB5linear rectangular beam runsVisible adjacent to the central-right area.

3950 horizontal grid spacing1650 horizontal grid spacing4500 horizontal grid spacing3625 horizontal grid spacing1625 horizontal dimension3400 vertical grid spacing1950 vertical grid spacing2650 vertical grid spacing+18 more

crop

p01_r05

page 1 · pile_p01_r05
Original
p01_r05
{
  "view": "Detail",
  "objects": [
    {
      "name": "pile reinforcement detail",
      "tag": "",
      "shape": "rectangular elevation",
      "material": "",
      "count": null,
      "note": "Detail title reads THROUGH PILE; left side of pile is cropped."
    },
    {
      "name": "reinforcement bar",
      "tag": "1-Y16",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Shown near top of pile detail."
    },
    {
      "name": "reinforcement bar",
      "tag": "6-Y16",
      "shape": "linear",
      "material": "",
      "count": 6,
      "note": "Callout is repeated at several levels of the pile detail."
    },
    {
      "name": "stiffener reinforcement bar",
      "tag": "Y16@1500 C/C",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Labeled STIFFNER as printed."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y8@150 C/C",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": ""
    },
    {
      "name": "cover block",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Callout reads COVER BLOCK @900 C/C."
    },
    {
      "name": "foundation/block symbol",
      "tag": "FB3",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Visible only in the partial lower layout."
    },
    {
      "name": "foundation/block symbol",
      "tag": "FB2",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Visible only in the partial lower layout."
    },
    {
      "name": "foundation/block symbol",
      "tag": "FB1",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Visible only in the partial lower layout."
    }
  ],
  "measurements": [
    {
      "label": "pile detail dimension",
      "value": "1500",
      "unit": "",
      "appliesTo": "pile reinforcement detail"
    },
    {
      "label": "pile detail dimension",
      "value": "600",
      "unit": "",
      "appliesTo": "pile reinforcement detail"
    },
    {
      "label": "pile length",
      "value": "7000",
      "unit": "",
      "appliesTo": "pile reinforcement detail"
    },
    {
      "label": "pile length",
      "value": "18000",
      "unit": "",
      "appliesTo": "pile reinforcement detail"
    },
    {
      "label": "pile length",
      "value": "11000",
      "unit": "",
      "appliesTo": "pile reinforcement detail"
    },
    {
      "label": "pile width",
      "value": "450",
      "unit": "",
      "appliesTo": "pile reinforcement detail"
    },
    {
      "label": "stiffener spacing",
      "value": "1500",
      "unit": "C/C",
      "appliesTo": "Y16@1500 C/C"
    },
    {
      "label": "reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "Y8@150 C/C"
    },
    {
      "label": "cover block spacing",
      "value": "900",
      "unit": "C/C",
      "appliesTo": "cover block"
    },
    {
      "label": "lower layout dimension",
      "value": "1625",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "lower layout dimension",
      "value": "2125",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "lower layout dimension",
      "value": "5350",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "lower layout dimension",
      "value": "4123",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "lower layout dimension",
      "value": "2057",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "lower layout dimension",
      "value": "1232",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "lower layout dimension",
      "value": "450+225",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "detail scale",
      "value": "1 : 25",
      "unit": "",
      "appliesTo": "THROUGH PILE"
    },
    {
      "label": "drawing scale",
      "value": "1:100, 1:25",
      "unit": "",
      "appliesTo": "title block"
    }
  ],
  "notes": [
    "CUT OFF LVL.",
    "CERTIFIED THAT THE PLAN HAS BE…",
    "ACCORDING TO THE PROVISIONS",
    "(BUILDING) RULES, 2007.",
    "CERTIFIED THAT I HAVE GONE THROU…",
    "(BUILDING) RULES, 2007, AND ALSO U…",
    "DURING AND AFTER THE CONSTRUCT…",
    "1. ALL DIMENSIONS ARE IN MILLIMETE… OTHERWISE STATED.",
    "2. ALL R.C.C. MEMBERS ARE IN M-25…",
    "3. USE Fe-550 GRADE OF STEEL CON…",
    "4. WRITTEN DIMENSIONS SHOULD BE…",
    "5. ALL FLOORS ARE WATER TIGHT.",
    "6. ALL OTHERS WORKS AS PER I.S. CO…"
  ],
  "labels": [
    "PROPOSED PARKING +",
    "BUILDING",
    "PLOT NO. - 281, SECT…",
    "CERTIFICATE OF ARCHITECT & ENGI…",
    "SIGNATURE OF STRUCTURAL ENGIN…",
    "MR. RUPAK KUMAR BANERJEE,",
    "STRUCTURAL ENGINEER | BE / I /44. K…",
    "CERTIFICATE OF OWNER",
    "SPECIFICATION OF BUILDING MATERIA…",
    "NOTES :",
    "DESIGNED BY :",
    "M K PAUL & …",
    "1st Floor, Mayur Kunjа, 186, Ram…",
    "Ph. No. - 9007308136,",
    "ARCHITECT:",
    "UTTAM KUMAR PAU…",
    "CA/89/12600",
    "SHEET SIZE: A0",
    "SHEET NO.:",
    "DRG. NO - MKPA/TECHNO/BUILDING/2…"
  ],
  "description": "The crop primarily shows a partial through-pile reinforcement detail, including longitudinal reinforcement, stiffeners, cover blocks, cut-off level, and pile length dimensions. It also contains a partial foundation/layout fragment at the bottom and the adjacent drawing title block, certificates, and general notes."
}

p01_r05Detail

  • foundation/block symbolFB3×1rectangularVisible only in the partial lower layout.
  • foundation/block symbolFB2×1rectangularVisible only in the partial lower layout.
  • foundation/block symbolFB1×1rectangularVisible only in the partial lower layout.

1500 pile detail dimension600 pile detail dimension7000 pile length18000 pile length11000 pile length450 pile width1500 C/C stiffener spacing150 C/C reinforcement spacing+10 more

crop

p01_r16

page 1 · stair_reinforcement_section_p01_r16
Original
p01_r16
{
  "view": "Detail",
  "objects": [
    {
      "name": "TB3 reinforced concrete beam reinforcement section",
      "tag": "TB3",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown with SPAN and SUPPORT reinforcement sections."
    },
    {
      "name": "FB3 reinforced concrete beam reinforcement section",
      "tag": "FB3",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown with a SPAN reinforcement section."
    },
    {
      "name": "stair flight",
      "tag": "",
      "shape": "stepped with sloping soffit",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Section Z-Z; reinforcement is shown along the sloping flight."
    },
    {
      "name": "intermediate landing slab",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "At INTERMEDIATE LEVEL."
    },
    {
      "name": "floor-level landing slab",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "At FLOOR LEVEL."
    },
    {
      "name": "upstand beam",
      "tag": "B15",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "At intermediate level."
    },
    {
      "name": "beam",
      "tag": "B13",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "At lower landing adjacent to stair flight."
    },
    {
      "name": "beam",
      "tag": "B16",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "At floor-level landing."
    },
    {
      "name": "foundation beam",
      "tag": "FB1",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Repeated in the lower plan fragment."
    },
    {
      "name": "foundation beam",
      "tag": "FB2",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Repeated in the lower plan fragment."
    },
    {
      "name": "foundation beam",
      "tag": "FB4",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Shown at stair/landing area in plan."
    },
    {
      "name": "foundation beam",
      "tag": "FB5",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Shown at right side of lower plan fragment."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y16",
      "shape": "linear bar",
      "material": "steel reinforcement",
      "count": null,
      "note": "Beam longitudinal reinforcement, including alternate and extra bottom bars."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y12",
      "shape": "linear bar",
      "material": "steel reinforcement",
      "count": null,
      "note": "Stair and landing reinforcement."
    },
    {
      "name": "reinforcement bar",
      "tag": "Y8",
      "shape": "link/stirrup and linear bar",
      "material": "steel reinforcement",
      "count": null,
      "note": "Beam links and stair reinforcement."
    },
    {
      "name": "stair/landing panel",
      "tag": "S1",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "Tag shown repeatedly in plan."
    },
    {
      "name": "stair/landing panel",
      "tag": "S2",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Tag shown in plan."
    },
    {
      "name": "stair/landing panel",
      "tag": "S4",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Tag shown adjacent to stair/landing area in plan."
    }
  ],
  "measurements": [
    {
      "label": "TB3 section depth",
      "value": "400",
      "unit": "",
      "appliesTo": "TB3"
    },
    {
      "label": "TB3 section width",
      "value": "250",
      "unit": "",
      "appliesTo": "TB3"
    },
    {
      "label": "TB3 transverse reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "TB3 Y8"
    },
    {
      "label": "TB3 longitudinal reinforcement",
      "value": "2-Y16",
      "unit": "",
      "appliesTo": "TB3"
    },
    {
      "label": "TB3 extra bottom reinforcement",
      "value": "+1-Y16",
      "unit": "",
      "appliesTo": "TB3"
    },
    {
      "label": "TB3 support section depth",
      "value": "450",
      "unit": "",
      "appliesTo": "TB3"
    },
    {
      "label": "TB3 support section width",
      "value": "250",
      "unit": "",
      "appliesTo": "TB3"
    },
    {
      "label": "FB3 section depth",
      "value": "450",
      "unit": "",
      "appliesTo": "FB3"
    },
    {
      "label": "FB3 section width",
      "value": "250",
      "unit": "",
      "appliesTo": "FB3"
    },
    {
      "label": "FB3 transverse reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "FB3 Y8"
    },
    {
      "label": "FB3 longitudinal reinforcement",
      "value": "2-Y16",
      "unit": "",
      "appliesTo": "FB3"
    },
    {
      "label": "FB3 extra top reinforcement",
      "value": "+2-Y16",
      "unit": "",
      "appliesTo": "FB3"
    },
    {
      "label": "intermediate-level horizontal dimension",
      "value": "500",
      "unit": "",
      "appliesTo": "intermediate landing"
    },
    {
      "label": "intermediate-level horizontal dimension",
      "value": "1200",
      "unit": "",
      "appliesTo": "intermediate landing"
    },
    {
      "label": "B15 depth",
      "value": "450",
      "unit": "",
      "appliesTo": "B15"
    },
    {
      "label": "intermediate landing/slab thickness",
      "value": "150",
      "unit": "",
      "appliesTo": "intermediate landing"
    },
    {
      "label": "stair reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "Y12"
    },
    {
      "label": "stair reinforcement spacing",
      "value": "150",
      "unit": "C/C",
      "appliesTo": "Y8"
    },
    {
      "label": "stair dimension",
      "value": "150",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "stair dimension",
      "value": "1200",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "stair dimension",
      "value": "300",
      "unit": "",
      "appliesTo": "stair flight"
    },
    {
      "label": "floor-level landing horizontal dimension",
      "value": "1400",
      "unit": "",
      "appliesTo": "floor-level landing"
    },
    {
      "label": "floor-level landing horizontal dimension",
      "value": "300",
      "unit": "",
      "appliesTo": "floor-level landing"
    },
    {
      "label": "B13 depth",
      "value": "450",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "B13 width",
      "value": "250",
      "unit": "",
      "appliesTo": "B13"
    },
    {
      "label": "B13/B16 horizontal dimension",
      "value": "1150",
      "unit": "",
      "appliesTo": "lower landing"
    },
    {
      "label": "right-side vertical dimension",
      "value": "300",
      "unit": "",
      "appliesTo": "floor-level landing"
    },
    {
      "label": "right-side horizontal dimension",
      "value": "500",
      "unit": "",
      "appliesTo": "floor-level landing"
    },
    {
      "label": "plan grid A-C dimension",
      "value": "3950",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan grid C-D dimension",
      "value": "1650",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan grid D-F dimension",
      "value": "4500",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan grid F offset",
      "value": "225",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "3400",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "1950",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "2650",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "2965",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "4125",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan stair/landing dimensions",
      "value": "740",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan stair/landing dimensions",
      "value": "1400",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "5350",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "6101",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan vertical dimension",
      "value": "1237",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan sloping dimension",
      "value": "4903",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan sloping dimension",
      "value": "2554",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "plan sloping dimension",
      "value": "1257",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "partial right-hand plan horizontal dimension",
      "value": "3950",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "partial right-hand plan horizontal dimension",
      "value": "625",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "partial right-hand plan vertical dimension",
      "value": "1950",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "partial right-hand plan vertical dimension",
      "value": "625",
      "unit": "",
      "appliesTo": "plan"
    },
    {
      "label": "partial right-hand plan vertical dimension",
      "value": "2650",
      "unit": "",
      "appliesTo": "plan"
    }
  ],
  "notes": [
    "2-Y16(ALTH.)",
    "Y8@150 C/C",
    "2-Y16(ALTH.) +1-Y16(EX.BOT.)",
    "2-Y16(ALTH.) +2-Y16(EX.TOP)",
    "Y12 @ 150 C/C",
    "Y8 @ 150 C/C",
    "NOT TO SCALE"
  ],
  "labels": [
    "SPAN",
    "SUPPORT",
    "DETAIL OF TB3",
    "SCALE = 1 : 25",
    "DETAIL OF FB3",
    "INTERMEDIATE LEVEL",
    "B15 (UP STAND BEAM) AT INTERMEDIATE LEVEL",
    "FLOOR LEVEL",
    "TYPICAL SECTIONAL DETAILS OF STAIR",
    "SECTION: Z-Z",
    "HALF LANDING BEAM",
    "N"
  ],
  "description": "The crop contains typical sectional reinforcement details for stair flight and landing construction, including intermediate and floor-level landings and beams B15, B13, and B16. It also includes TB3 and FB3 beam reinforcement sections at the top and a partial lower plan showing foundation beams FB1, FB2, FB4, and FB5 around stair/landing panels."
}

p01_r16Detail

  • foundation beamFB1rectangularRepeated in the lower plan fragment.
  • foundation beamFB2rectangularRepeated in the lower plan fragment.
  • foundation beamFB4×1rectangularShown at stair/landing area in plan.
  • foundation beamFB5rectangularShown at right side of lower plan fragment.

400 TB3 section depth250 TB3 section width150 C/C TB3 transverse reinforcement spacing2-Y16 TB3 longitudinal reinforcement+1-Y16 TB3 extra bottom reinforcement450 TB3 support section depth250 TB3 support section width450 FB3 section depth+42 more