Matched toDeck Waterproofingbridge.superstructure.deck_system.waterproofingon “Waterproofing”
| The class asks for | Value | How | From |
|---|---|---|---|
| LengthLwants m/mm | not establishedThe waterproofing callout in the endwall section gives only a specification reference and no extents or length dimension. The shown dimensions apply to the endwall, slab, beam, reinforcement, or joint filler, not to waterproofing. | not found | |
| WidthWwants m/mm | not establishedNo waterproofing width or transverse coverage extent is stated. Dimensions in the section are not identified as waterproofing dimensions. | not found | |
| Surface AreaA_surfacewants m2 | not establishedNeither waterproofing length nor width is established, so its surface area cannot be derived. | not found | |
| Material TypeMAT | Waterproofing per Section 530 of the Georgia DOT SpecificationsThe waterproofing note explicitly directs that waterproofing comply with Section 530 of the Georgia DOT Specifications. No more specific product or membrane type is stated. | read | p8 · p08_r04p8 · p08_r04 section at end bent showing beam seat reinforcement layout |
Worked out by openai/gpt-5.6-terra-pro from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.
Every dimension read for it5
- 12”horizontal dimensionnot attributedp8 · p08_r04 section at end bent showing beam seat reinforcement layout
- 1’-6”horizontal dimensionnot attributedp8 · p08_r04 section at end bent showing beam seat reinforcement layout
- 8”horizontal dimensionnot attributedp8 · p08_r04 section at end bent showing beam seat reinforcement layout
- 3 1/2”minimum clearancenot attributedp8 · p08_r04 section at end bent showing beam seat reinforcement layout
- 2”clear covernot attributedp8 · p08_r04 section at end bent showing beam seat reinforcement layout
Notes on the sheets that carry it
- p2WELDING - ALL WELDING ON GEORGIA DOT PROJECTS SHALL BE PERFORMED BY GDOT CERTIFIED WELDERS THAT HAVE IN THEIR POSSESSION A CURRENT WELDING CERTIFICATION CARD ISSUED BY THE OFFICE OF MATERIALS AND TESTING. USE ONLY E70XX (EXCLUDING E7014 AND E7024) LOW HYDROGEN ELECTRODES FOR MANUAL SHIELDED METAL ARC WELDING.
- p2SPECIAL PROTECTIVE COATING - CLEAN AND PAINT PILES AND SWAYBRACING WITH SPECIAL PROTECTIVE COATING NO. 2P IN ACCORDANCE WITH SECTIONS 520 AND 535 OF THE GEORGIA DOT SPECIFICATIONS. EXTEND COATING FROM TOP OF PILE TO 2FT BELOW GROUND FOR END BENT PILING. EXTEND COATING FROM BOTTOM OF CAP OR PEDESTAL FOOTING TO 5FT BELOW GROUND FOR INTERMEDIATE BENT PILING, REGARDLESS OF ENCASEMENT.
- p2SHOP DRAWING SUBMISSION - SUBMIT SHOP DRAWINGS WITH DEPENDENT INFORMATION AS A SET. SHOP DRAWINGS FOR BEAMS, METAL DECK FORMS AND STEEL DIAPHRAGMS WILL NOT BE REVIEWED UNTIL ALL HAVE BEEN RECEIVED.
- p2INCIDENTAL ITEMS - INCLUDE THE COST INCIDENTAL TO THE WORK THAT IS NOT SPECIFICALLY COVERED BY THE GEORGIA STANDARD SPECIFICATIONS, SUPPLEMENTAL SPECIFICATIONS AND/OR SPECIAL PROVISIONS IN THE OVERALL BID SUBMITTED. THIS INCLUDES THE COST OF WATERPROOFING, JOINT FILLERS AND OTHER INCIDENTAL ITEMS NECESSARY TO COMPLETE THE WORK.
- p85 506B AT 18" ±, ALT. TO GIVE 9" SP.
- p83 1/2" MIN. CL.
- p8506A AT 18"
- p82" CL. 3 SIDES
- p88-504B AT 12" ± BETWEEN BEAMS
- p82-504A AT END OF BEAM
- p81/2" PREFORMED JOINT FILLER
- p8BEARING PAD NOT SHOWN
- p8WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS
- p8SLAB REINFORCEMENT NOT SHOWN
- p8506B AT 18” ±, ALT. TO GIVE 9” SP.
- p8END BENT 1 SHOWN END BENT 4 SIMILAR
Every crop it was read in — the drawing beside what the model took off it
Page 2
p02_r19 general notes continuedNotes
- WaterproofingListed as an incidental cost item.
2 FT Coating extension below ground for end bent piling5 FT Coating extension below ground for intermediate bent piling
p02_r19Notes
- WaterproofingIncluded as an incidental cost item.
2FT FT Coating extension below ground for end bent piling5FT FT Coating extension below ground for intermediate bent piling
Page 8
p08_r04Section
- waterproofing×1layerSee Section 530 of the Georgia DOT Specifications.
12" horizontal dimension1'-6" horizontal dimension8" horizontal dimension1/4" radius18" ± bar spacing9" alternating spacing3 1/2" minimum clear cover18" bar spacing+10 more
p08_r04 section at end bent showing beam seat reinforcement layoutSection
- waterproofinglayerSee Section 530 of the Georgia DOT Specifications.
12” horizontal dimension1’-6” horizontal dimension8” horizontal dimension1/4” radius18” ± 506B spacing9” alternate spacing3 1/2” minimum clearance10” vertical dimension+10 more