⚠ No class in the bridge ontology fits this itemAdd a class
The ontology would need a coping component class.
How the sheets named it
Every dimension read for it8
- 1'-6 3/16"Partial dimension at top of cropnot attributedp10 · p10_r05 general construction notes 1 12 for beam
- 6'-0" MIN.minimum horizontal distance from B.F.P.R. reference to wallnot attributedp13 · p13_r06 schematic of cap coping and front face wall alignment
- 2" MIN.minimum clearancenot attributedp13 · p13_r06 schematic of cap coping and front face wall alignment
- 1'-0"typical vertical dimensionnot attributedp13 · p13_r06 schematic of cap coping and front face wall alignment
- 2"clearance, 3 sidesnot attributedp13 · p13_r06 schematic of cap coping and front face wall alignment
- 1'-6"horizontal dimensionnot attributedp13 · p13_r06 schematic of cap coping and front face wall alignment
- 3'-0"partial dimension at left crop edgenot attributedp13 · p13_r06 schematic of cap coping and front face wall alignment
- 6'-0" MIN.minimum distance from B.F.P.R. to wall/front referencenot attributedp17 · p17_r09 section through end bent cap wall and coping
Notes on the sheets that carry it
- p101. BEAMS SHALL BE MAINTAINED IN AN UPRIGHT POSITION AT ALL TIMES AND SHALL BE PICKED UP WITHIN 4'-6" FROM THEIR ENDS. DISREGARDING THIS REQUIREMENT COULD LEAD TO COLLAPSE OF THE BEAM. PICK-UPS SHALL BE EMBEDDED TO WITHIN 4" OF THE BOTTOM OF THE BEAM. DETAILS OF PICK-UPS SHALL BE INCLUDED IN THE SHOP DRAWINGS.
- p102. CHAMFER EDGES OF BEAMS 1/2" OR 3/4".
- p103. HORIZONTAL DIMENSIONS ARE IN PLACE DIMENSIONS. THE BEAM LENGTH INCLUDES THE 1/8" EPOXY MORTAR AT EACH END. SHOP DRAWINGS SHALL ADJUST HORIZONTAL DIMENSIONS FOR GRADE AND FABRICATION EFFECTS SUCH AS SHRINKAGE AND ELASTIC SHORTENING.
- p104. AT ℄ BEARING, FORM A 1 3/4" DIAMETER X 7" DEEP HOLE AT THE FIXED ENDS AND A 4" X 1 3/4" X 7" DEEP SLOT AT THE EXPANSION ENDS FOR A 1 1/2" DIAMETER SMOOTH DOWEL. SEE PLAN AND ELEVATION SHEET FOR LOCATION OF FIXED AND EXPANSION ENDS.
- p105. TOPS OF BEAMS SHALL BE ROUGH FLOATED AT APPROXIMATELY THE TIME OF INITIAL SET. ENTIRE TOP SHALL BE SCRUBBED TRANSVERSELY WITH A COARSE BRUSH TO REMOVE ALL LAITANCE AND TO PRODUCE A ROUGHENED SURFACE FOR BONDING TO THE SLAB. ROUGHENED SURFACE SHALL HAVE AN AMPLITUDE OF APPROXIMATELY 1/4". CONCRETE FINS OR PROJECTIONS SHALL BE REMOVED TO PRODUCE A VERTICAL FACE AT THE EDGE OF THE BEAM.
- p106. ALL HOLES FORMED INTO THE BEAMS TO FACILITATE TRANSPORT SHALL BE FILLED AND GIVEN A TYPE I FINISH, PRIOR TO ACCEPTANCE OF THE BEAM. REMOVE PVC OR SIMILAR FORMING MATERIALS FROM EACH HOLE, EXPOSING THE CONCRETE SURFACE. COAT INTERIOR OF HOLE WITH A TYPE II EPOXY RESIN ADHESIVE IN ACCORDANCE WITH GEORGIA STANDARD SPECIFICATION 886 AND FILL WITH A RAPID SETTING PATCHING MATERIAL IN ACCORDANCE WITH GEORGIA STANDARD SPECIFICATION 934.
- p107. NON-COMPOSITE DEAD LOAD DEFLECTION (ΔNC) AT THE MIDPOINT IS DUE TO THE WEIGHT OF THE SLAB AND COPING.
- p108. COMPOSITE DEAD LOAD DEFLECTION (ΔC) AT THE MIDPOINT IS DUE TO THE WEIGHT OF BARRIER.
- p109. STRANDS SHALL MEET ALL REQUIREMENTS OF ASTM A 416 GRADE 270.
- p1010. PRESTRESSING DATA IS AS FOLLOWS:
- p10A. USE 20 - 1/2" DIAMETER SPECIAL LOW-RELAXATION (A = 0.167 SQ IN) STRANDS. PRETENSION STRANDS TO 33,818 LBS EACH.
- p10B. PRETENSIONED STRANDS SHALL BE RELEASED AFTER THE CONCRETE HAS REACHED A MINIMUM STRENGTH (fci) OF 5,200 PSI.
- p10C. INCLUDING THE TOP STRANDS, THE TOTAL JACKING FORCE OF PRETENSIONING IS 676,350 LBS.
- p10D. INCLUDING THE TOP STRANDS, THE NET PRESTRESSING FORCE OF THE STRANDS AFTER ALL LOSSES IS 536,584 LBS.
- p1011. CONCRETE STRENGTH (f'c) = 6,500 PSI.
- p1012. ALLOWABLE PSC BEAM TENSION = 484 PSI.
- p104. AT [symbol unclear] BEARING, FORM A 1 3/4″ DIAMETER X 7″ DEEP HOLE AT THE FIXED ENDS AND A 4″ X 1 3/4″ X 7″ DEEP SLOT AT THE EXPANSION ENDS FOR A 1 1/2″ DIAMETER SMOOTH DOWEL. SEE PLAN AND ELEVATION SHEET FOR LOCATION OF FIXED AND EXPANSION ENDS.
- p111. BEAMS SHALL BE MAINTAINED IN AN UPRIGHT POSITION AT ALL TIMES AND SHALL BE PICKED UP WITHIN 5’-6” FROM THEIR ENDS. DISREGARDING THIS REQUIREMENT COULD LEAD TO COLLAPSE OF THE BEAM. PICK-UPS SHALL BE EMBEDDED TO WITHIN 4” OF THE BOTTOM OF THE BEAM. DETAILS OF PICK-UPS SHALL BE INCLUDED IN THE SHOP DRAWINGS.
- p17PILES ARE DESIGNED FOR A MAXIMUM FACTORED AXIAL LOAD OF 212 KIPS.
- p17ALL PILES SHALL BE STEEL H, HP 12 X 53.
- p17ALL PILES SHALL BE DRIVEN TO A DRIVING RESISTANCE OF 326 KIPS AFTER A MINIMUM TIP ELEVATION OF 122 AT BENT 4L AND 144 AT BENT 4R IS ACHIEVED.
Every crop it was read in — the drawing beside what the model took off it
Page 10
p10_r05 general construction notes 1 12 for beamNotes
- copingReferenced for non-composite dead-load deflection.
1'-6 3/16" Partial dimension at top of crop4'-6" Beam pickup distance from ends4" Pickup embedment distance from bottom of beam1/2" OR 3/4" Beam edge chamfer1/8" Epoxy mortar at each beam end1 3/4" Fixed-end hole diameter7" Fixed-end hole depth4" X 1 3/4" X 7" Expansion-end slot size+11 more
p10_r09 notes of psc beamNotes
- copingReferenced as contributing to non-composite dead-load deflection.
1/8″ Epoxy mortar thickness at each beam end1 3/4″ Diameter of hole at fixed ends7″ Depth of hole at fixed ends4″ Slot width at expansion ends1 3/4″ Slot dimension at expansion ends7″ Slot depth at expansion ends1 1/2″ Smooth dowel diameter1/4″ Roughened surface amplitude+1 more
p10_r09Notes
- copingReferenced as contributing to non-composite dead-load deflection.
1/8" epoxy mortar at each beam end1 3/4" fixed-end hole diameter7" fixed-end hole depth4" expansion-end slot width1 3/4" expansion-end slot length7" expansion-end slot depth1 1/2" smooth dowel diameter1/4" roughened top-surface amplitude
Page 11
p11_r10Notes
- CopingReferenced as contributing to non-composite dead load deflection.
5’-6” Pick-up location from beam ends4” Pick-up embedment from bottom of beam1/2” Beam edge chamfer3/4” Beam edge chamfer1/8” Epoxy mortar at each beam end1 3/4” Fixed-end hole diameter7” Fixed-end hole depth4” Expansion-end slot width+8 more
p11_r10 notes of beam notesNotes
- copingReferenced in non-composite dead load deflection note.
5'-6" Pick-up distance from beam ends4" Pick-up embedment from bottom of beam1/2" Beam edge chamfer3/4" Beam edge chamfer1/8" Epoxy mortar at each beam end1 3/4" Fixed-end hole diameter7" Fixed-end hole depth4" Expansion-end slot width+4 more
Page 13
p13_r06Section
- coping×1rectangularLabeled COPING.
3'-0" horizontal dimension2" MIN. CL. minimum clear cover1'-0" TYP. typical vertical dimension2'-0" MIN. minimum vertical dimension2" CL. 3 SIDES clear cover, 3 sides1'-6" horizontal dimension6'-0" MIN. minimum horizontal dimension3'-0" horizontal dimension+3 more
p13_r06 schematic of cap coping and front face wall alignmentCross Section
- coping×1rectangularShown at the top of the wall.
6'-0" MIN. minimum horizontal distance from B.F.P.R. reference to wall3'-0" cap width2'-0" MIN. minimum cap height2" MIN. minimum clearance1'-0" typical vertical dimension2" clearance, 3 sides1'-6" horizontal dimension3'-0" partial dimension at left crop edge+1 more
Page 17
p17_r09Section
- coping×1rectangularCallout identifies COPING at top of wall.
6'-0" MIN. minimum horizontal dimension3'-0" horizontal dimension2'-0" MIN. minimum vertical dimension212 KIPS maximum factored axial load326 KIPS driving resistance122 minimum tip elevation144 minimum tip elevation12.0 CY Class AA concrete quantity+4 more
p17_r09 section through end bent cap wall and copingSection
- copingCOPING×1rectangular
6'-0" MIN. minimum distance from B.F.P.R. to wall/front reference3'-0" cap width2'-0" MIN. minimum cap depth3/4" = 1'-0" scale212 KIPS factored axial load326 KIPS pile driving resistance122 minimum tip elevation at Bent 4L144 minimum tip elevation at Bent 4R+4 more
p17_r10 cross section of cap wall coping and pilesSection
- coping×1rectangularShown at top of wall.
6'-0" MIN. minimum horizontal dimension3'-0" horizontal dimension212 KIPS maximum factored axial loadHP 12 X 53 pile designation326 KIPS driving resistance122 minimum tip elevation at Bent 4L144 minimum tip elevation at Bent 4R3/4" = 1'-0" scale