Truss bracing

Notes on the sheets that carry it

  • p8NOTE: BARS 401, 504 SERIES, 505, AND 506 SERIES NOT SHOWN
  • p8FENCE NOTES:
  • p81. FENCE SHALL BE 9 GAGE CHAIN LINK ZINC COATED TWO INCH SECURITY FENCE.
  • p82. CAST 4" DIA. GALVANIZED SLEEVE IN THE PARAPET. ALLOW NON-SHRINK, NON-METALLIC GROUT TO CURE FOR THREE DAYS BEFORE FENCE FABRIC IS INSTALLED.
  • p83. APPLY GALVANIZING REPAIR COMPOUND, IN ACCORDANCE WITH GEORGIA DOT SPECIFICATION 645, TO ENDS OF 4" DIA. GALVANIZED SLEEVES.
  • p84. PROVIDE EXPANSION SLEEVE FOR ALL RAILS TO MATCH SUPERSTRUCTURE JOINTS.
  • p85. FASTEN FABRIC TO POSTS AT INTERVALS NOT GREATER THAN 14".
  • p86. SPACE POSTS AT A MINIMUM OF 7'-0" AND A MAXIMUM OF 10'-0". PLACE POSTS 1'-0" MINIMUM FROM JOINTS IN BARRIER. SEE DECK PLAN FOR POST SPACING.
  • p87. FOR FURTHER DETAILS, SEE GEORGIA DOT SPECIFICATIONS SECTIONS 643 AND 894.
  • p8WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS
  • p8SLAB REINFORCEMENT NOT SHOWN
  • p8END BENT 1 SHOWN, END BENT 4 SIMILAR
  • p8* NON-SHRINK, NON-METALLIC PORTLAND CEMENT GROUT IN ACCORDANCE WITH ASTM C1107, TROWEL TO PROVIDE POSITIVE DRAINAGE.
  • p8REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.

Every crop it was read in — the drawing beside what the model took off it

Page 8

crop

p08_r01 for further details see georgia dot spec

page 8 · gdot_plan_649084f395824aaebf1f5ed48132696f_p08_r01_for_further_details_see_georgia_dot_spec
Original
p08_r01 for further details see georgia dot spec
{
  "view": "Detail",
  "objects": [
    {
      "name": "Endwall",
      "tag": "3'-0\" ENDWALL",
      "shape": "rectangular/tapered",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in Section Thru Endwall at left side of deck"
    },
    {
      "name": "Endwall",
      "tag": "1'-6\" ENDWALL",
      "shape": "rectangular/tapered",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in Section Thru Endwall, inboard of 3'-0\" endwall"
    },
    {
      "name": "Deck slab",
      "tag": "SLAB",
      "shape": "tapered, cross-slope 2%",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Spans full width shown, SR 21 WB = PGL centerline marked"
    },
    {
      "name": "Girder/Beam",
      "tag": "",
      "shape": "bulb-tee / I-section (PSC beam)",
      "material": "precast concrete",
      "count": 5,
      "note": "Repeating beam sections shown under deck slab; rebar marks 900A/900B point to beam tops"
    },
    {
      "name": "Preformed joint filler",
      "tag": "",
      "shape": "strip",
      "material": "preformed foam/elastomeric",
      "count": 3,
      "note": "1/2\" preformed joint filler (typ.) and 1\" preformed foam joint filler around pad"
    },
    {
      "name": "Construction joint",
      "tag": "",
      "shape": "linear joint",
      "material": "",
      "count": 1,
      "note": "Required construction joint parallel with deck, 1\" gap min."
    },
    {
      "name": "Barrier",
      "tag": "",
      "shape": "tapered/rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in Fence Elevation and Fence Post Detail, supports fence"
    },
    {
      "name": "End post (fence)",
      "tag": "",
      "shape": "vertical pipe",
      "material": "galvanized/zinc coated steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Pull post (fence)",
      "tag": "",
      "shape": "2 7/8\" dia pipe",
      "material": "zinc coated steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Fence post (typical vertical)",
      "tag": "",
      "shape": "2 7/8\" dia pipe, curved top 45°",
      "material": "zinc coated steel",
      "count": null,
      "note": "Post spaced per Fence Notes 6, curved top detail with 2'-6\" R"
    },
    {
      "name": "Tension bar",
      "tag": "",
      "shape": "1 5/8\" dia pipe",
      "material": "zinc coated steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Truss bracing",
      "tag": "",
      "shape": "diagonal 1 5/8\" dia pipe",
      "material": "zinc coated steel",
      "count": null,
      "note": "At end or pull post"
    },
    {
      "name": "Chain link fence fabric",
      "tag": "",
      "shape": "woven mesh",
      "material": "zinc coated steel, 9 gage",
      "count": 1,
      "note": "Security fence, 2 inch mesh"
    },
    {
      "name": "Pipe sleeve",
      "tag": "",
      "shape": "circular",
      "material": "galvanized steel",
      "count": 1,
      "note": "4\" dia. std. wt. pipe sleeve cast in barrier"
    },
    {
      "name": "End bent cap/section",
      "tag": "END BENT 1",
      "shape": "as detailed in Section at Endwall",
      "material": "reinforced concrete",
      "count": 1,
      "note": "End Bent 4 similar per note"
    },
    {
      "name": "Reinforcement bar",
      "tag": "900A",
      "shape": "bent bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "4-900A called out at girder top"
    },
    {
      "name": "Reinforcement bar",
      "tag": "900B",
      "shape": "bent bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "4-900B called out at girder tops, two locations"
    },
    {
      "name": "Reinforcement bar",
      "tag": "401",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "4-401 shown in Section at Endwall; series not shown in main section per note"
    },
    {
      "name": "Reinforcement bar",
      "tag": "504A",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "2-504A AT END"
    },
    {
      "name": "Reinforcement bar",
      "tag": "504B",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "8-504B AT 12\"± BETWEEN BEAMS"
    },
    {
      "name": "Reinforcement bar",
      "tag": "505",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "1-505 shown"
    },
    {
      "name": "Reinforcement bar",
      "tag": "506A",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "506B",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "506B AT 18\"± ALT. TO GIVE 9\" SP."
    },
    {
      "name": "Bearing",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Called out as 'BEARING NOT S[HOWN]' - not depicted, text partial/cut off"
    },
    {
      "name": "Slab reinforcement",
      "tag": "",
      "shape": "",
      "material": "reinforcement steel",
      "count": null,
      "note": "Noted as not shown in Section at Endwall"
    }
  ],
  "measurements": [
    {
      "label": "Overhang width",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "Section Thru Endwall, left edge"
    },
    {
      "label": "Width",
      "value": "1'-8\"",
      "unit": "ft-in",
      "appliesTo": "Section Thru Endwall, left edge"
    },
    {
      "label": "Width",
      "value": "34'-0\"",
      "unit": "ft-in",
      "appliesTo": "Section Thru Endwall, main span"
    },
    {
      "label": "Width",
      "value": "6'-8\"",
      "unit": "ft-in",
      "appliesTo": "Section Thru Endwall, right side"
    },
    {
      "label": "Width",
      "value": "1'-1\"",
      "unit": "ft-in",
      "appliesTo": "Section Thru Endwall, right edge"
    },
    {
      "label": "Barrier height at right",
      "value": "3'-6\"",
      "unit": "ft-in",
      "appliesTo": "Section Thru Endwall right barrier"
    },
    {
      "label": "Cross slope",
      "value": "2",
      "unit": "%",
      "appliesTo": "Deck slab"
    },
    {
      "label": "Gap min.",
      "value": "1",
      "unit": "in",
      "appliesTo": "Construction joint at deck"
    },
    {
      "label": "Joint filler thickness",
      "value": "1/2",
      "unit": "in",
      "appliesTo": "Preformed joint filler, typical"
    },
    {
      "label": "Joint filler thickness",
      "value": "1",
      "unit": "in",
      "appliesTo": "Preformed foam joint filler around pad"
    },
    {
      "label": "Post spacing max",
      "value": "12",
      "unit": "in",
      "appliesTo": "Tension bar bands O.C. max"
    },
    {
      "label": "Pipe diameter",
      "value": "1 5/8",
      "unit": "in",
      "appliesTo": "Tension bar/truss bracing pipe, zinc coated"
    },
    {
      "label": "Pipe diameter",
      "value": "2 7/8",
      "unit": "in",
      "appliesTo": "Fence pipe, typical"
    },
    {
      "label": "Pull post width",
      "value": "2 7/8",
      "unit": "in",
      "appliesTo": "Pull post diameter"
    },
    {
      "label": "Offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Fence elevation, base dimension"
    },
    {
      "label": "Offset",
      "value": "1/2",
      "unit": "in",
      "appliesTo": "Offset dimension in fence elevation"
    },
    {
      "label": "Fence height",
      "value": "5'-1\"",
      "unit": "ft-in",
      "appliesTo": "Fence Post Detail"
    },
    {
      "label": "Fence height",
      "value": "4'-7\"",
      "unit": "ft-in",
      "appliesTo": "Fence Post Detail"
    },
    {
      "label": "Total height",
      "value": "10'-4\"",
      "unit": "ft-in",
      "appliesTo": "Fence Post Detail total"
    },
    {
      "label": "Fence height",
      "value": "7'-0\"",
      "unit": "ft-in",
      "appliesTo": "Zinc coated fence height"
    },
    {
      "label": "Base height",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Fence Post Detail base"
    },
    {
      "label": "Barrier height",
      "value": "3'-6\"",
      "unit": "ft-in",
      "appliesTo": "Fence Post Detail barrier"
    },
    {
      "label": "Curve radius",
      "value": "2'-6\"",
      "unit": "ft-in",
      "appliesTo": "Fence Post Detail curved top, R"
    },
    {
      "label": "Angle",
      "value": "45",
      "unit": "degrees",
      "appliesTo": "Fence Post Detail curved top"
    },
    {
      "label": "Offset dimension",
      "value": "10 1/4\"",
      "unit": "in",
      "appliesTo": "Fence Post Detail"
    },
    {
      "label": "Pipe sleeve diameter",
      "value": "4",
      "unit": "in",
      "appliesTo": "Pipe sleeve, std wt"
    },
    {
      "label": "Section at Endwall width",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "Section at Endwall top dimension"
    },
    {
      "label": "Section at Endwall width",
      "value": "1'-6\"",
      "unit": "ft-in",
      "appliesTo": "Section at Endwall"
    },
    {
      "label": "Section at Endwall width",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "Section at Endwall"
    },
    {
      "label": "Radius",
      "value": "1/4\"",
      "unit": "in",
      "appliesTo": "Section at Endwall, R"
    },
    {
      "label": "Clear cover",
      "value": "3 1/2",
      "unit": "in min",
      "appliesTo": "Section at Endwall min. clearance"
    },
    {
      "label": "Depth",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "Section at Endwall"
    },
    {
      "label": "Depth",
      "value": "9\"",
      "unit": "in",
      "appliesTo": "Section at Endwall"
    },
    {
      "label": "Depth",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "Section at Endwall"
    },
    {
      "label": "Depth",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Section at Endwall"
    },
    {
      "label": "Clearance",
      "value": "2\" CL. 3 SIDES",
      "unit": "in",
      "appliesTo": "Section at Endwall reinforcement clearance"
    },
    {
      "label": "Spacing",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "Section at Endwall dimension near 506A"
    },
    {
      "label": "Bar spacing",
      "value": "18\"±",
      "unit": "in",
      "appliesTo": "506B bar spacing"
    },
    {
      "label": "Alt spacing",
      "value": "9\"",
      "unit": "in",
      "appliesTo": "506B alternate spacing"
    },
    {
      "label": "Bar spacing",
      "value": "12\"±",
      "unit": "in",
      "appliesTo": "504B bar spacing between beams"
    },
    {
      "label": "Post fastening interval max",
      "value": "14",
      "unit": "in",
      "appliesTo": "Fence fabric fastening (Fence Note 5)"
    },
    {
      "label": "Post spacing min",
      "value": "7'-0\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing minimum (Fence Note 6)"
    },
    {
      "label": "Post spacing max",
      "value": "10'-0\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing maximum (Fence Note 6)"
    },
    {
      "label": "Post distance from joint",
      "value": "1'-0\"",
      "unit": "ft-in min",
      "appliesTo": "Fence post minimum distance from barrier joints (Fence Note 6)"
    }
  ],
  "notes": [
    "NOTE: BARS 401, 504 SERIES, 505, AND 506 SERIES NOT SHOWN",
    "FENCE NOTES:",
    "1. FENCE SHALL BE 9 GAGE CHAIN LINK ZINC COATED TWO INCH SECURITY FENCE.",
    "2. CAST 4\" DIA. GALVANIZED SLEEVE IN THE PARAPET. ALLOW NON-SHRINK, NON-METALLIC GROUT TO CURE FOR THREE DAYS BEFORE FENCE FABRIC IS INSTALLED.",
    "3. APPLY GALVANIZING REPAIR COMPOUND, IN ACCORDANCE WITH GEORGIA DOT SPECIFICATION 645, TO ENDS OF 4\" DIA. GALVANIZED SLEEVES.",
    "4. PROVIDE EXPANSION SLEEVE FOR ALL RAILS TO MATCH SUPERSTRUCTURE JOINTS.",
    "5. FASTEN FABRIC TO POSTS AT INTERVALS NOT GREATER THAN 14\".",
    "6. SPACE POSTS AT A MINIMUM OF 7'-0\" AND A MAXIMUM OF 10'-0\". PLACE POSTS 1'-0\" MINIMUM FROM JOINTS IN BARRIER. SEE DECK PLAN FOR POST SPACING.",
    "7. FOR FURTHER DETAILS, SEE GEORGIA DOT SPECIFICATIONS SECTIONS 643 AND 894.",
    "WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS",
    "SLAB REINFORCEMENT NOT SHOWN",
    "END BENT 1 SHOWN, END BENT 4 SIMILAR",
    "* NON-SHRINK, NON-METALLIC PORTLAND CEMENT GROUT IN ACCORDANCE WITH ASTM C1107, TROWEL TO PROVIDE POSITIVE DRAINAGE.",
    "REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP."
  ],
  "labels": [
    "SECTION THRU ENDWALL",
    "(LOOKING AHEAD, LEFT BRIDGE SHOWN, RIGHT BRIDGE SIMILAR)",
    "FENCE ELEVATION",
    "SCALE: 3/4\" = 1'-0\"",
    "FENCE POST DETAIL",
    "SECTION AT ENDWALL",
    "SCALE: 3/4\" = 1'-0\"",
    "SR 21 WB = PGL",
    "END POST",
    "CONST. JOINT",
    "BARRIER",
    "SLAB",
    "ZINC COATED FENCE",
    "TENSION BAR BANDS AT 12\" O.C. MAX.",
    "TENSION BAR ZINC COATED",
    "1 5/8\" DIA. PIPE ZINC COATED",
    "2 7/8\" DIA. PIPE, TYP.",
    "TRUSS BRACING AT END OR PULL",
    "POST VERT. ZINC COATED",
    "2 7/8\" PULL POST",
    "1/2\" OFFSET",
    "4\" DIA. STD. WT. PIPE SLEEVE",
    "7'-0\" ZINC COATED FENCE",
    "2 7/8\" DIA. PIPE"
  ],
  "description": "This sheet contains four related details for a bridge structure: a full-width Section Thru Endwall showing the deck cross-slope, precast beams, endwalls and joint fillers with rebar callouts 900A/900B; a Fence Elevation and Fence Post Detail showing chain link security fence construction with tension bars, truss bracing, and post dimensions atop a concrete barrier; and a Section at Endwall (End Bent 1, similar at End Bent 4) showing end bent reinforcement details (bars 900, 401, 504A, 504B, 506A, 506B, 505) with bearing area and waterproofing notes. It documents deck cross-section geometry, endwall/joint details, security fence construction requirements per Georgia DOT specifications, and end bent reinforcement layout for the barrier and beam seat area."
}

p08_r01 for further details see georgia dot specDetail

  • Truss bracingdiagonal 1 5/8" dia pipezinc coated steelAt end or pull post

1 1/2 in Overhang width1'-8" ft-in Width34'-0" ft-in Width6'-8" ft-in Width1'-1" ft-in Width3'-6" ft-in Barrier height at right2 % Cross slope1 in Gap min.+36 more

crop

p08_r01

page 8 · other_p08_r01
Original
p08_r01
{
  "view": "Detail",
  "objects": [
    {
      "name": "Endwall",
      "tag": "3'-0\" ENDWALL",
      "shape": "rectangular/tapered",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Larger endwall shown at left of section thru endwall"
    },
    {
      "name": "Endwall",
      "tag": "1'-6\" ENDWALL",
      "shape": "rectangular/tapered",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Smaller endwall shown at right side of deck"
    },
    {
      "name": "Girder",
      "tag": "",
      "shape": "I-girder",
      "material": "structural steel or precast concrete",
      "count": 6,
      "note": "Repeated girder sections shown in Section Thru Endwall"
    },
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "4-900B",
      "shape": "",
      "material": "reinforced steel",
      "count": 2,
      "note": "Located at each endwall"
    },
    {
      "name": "Reinforcement bar",
      "tag": "4-900A",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": "Located mid-span area of section"
    },
    {
      "name": "Preformed joint filler",
      "tag": "",
      "shape": "strip",
      "material": "preformed elastomeric material",
      "count": 3,
      "note": "1/2\" and 1\" thicknesses noted at joints and around pad"
    },
    {
      "name": "Construction joint",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Required construction joint parallel with deck"
    },
    {
      "name": "Barrier",
      "tag": "",
      "shape": "tapered/rectangular",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Shown in Fence Elevation and Fence Post Detail atop slab"
    },
    {
      "name": "Fence",
      "tag": "",
      "shape": "chain link with pipe posts",
      "material": "zinc coated steel",
      "count": 1,
      "note": "9 gage chain link security fence per notes"
    },
    {
      "name": "Fence post",
      "tag": "",
      "shape": "pipe, curved top",
      "material": "zinc coated steel",
      "count": 1,
      "note": "2 7/8\" dia. pipe pull post with truss bracing"
    },
    {
      "name": "Pipe sleeve",
      "tag": "",
      "shape": "circular",
      "material": "galvanized steel",
      "count": 1,
      "note": "4\" dia. std. wt. pipe sleeve cast in parapet"
    },
    {
      "name": "Tension bar",
      "tag": "",
      "shape": "linear",
      "material": "zinc coated steel",
      "count": 1,
      "note": "Tension bar bands at 12\" o.c. max."
    },
    {
      "name": "Truss bracing",
      "tag": "",
      "shape": "diagonal",
      "material": "zinc coated steel",
      "count": 1,
      "note": "At end or pull post"
    },
    {
      "name": "End Bent",
      "tag": "END BENT 1 / END BENT 4",
      "shape": "",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Section at Endwall shows End Bent 1; End Bent 4 similar per note"
    },
    {
      "name": "Reinforcement bar",
      "tag": "1-505",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": "Shown in Section at Endwall"
    },
    {
      "name": "Reinforcement bar",
      "tag": "506B",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": "At 18\" spacing, alt. to give 9\" sp."
    },
    {
      "name": "Reinforcement bar",
      "tag": "506A",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "4-900",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "8-504B",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": "At 12\"± between beams"
    },
    {
      "name": "Reinforcement bar",
      "tag": "2-504A",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": "At end of beam (text cut off)"
    },
    {
      "name": "Reinforcement bar",
      "tag": "4-401",
      "shape": "",
      "material": "reinforced steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bearing",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 1,
      "note": "Labeled 'BEARING NOT SH[OWN]', partially cut off"
    },
    {
      "name": "Waterproofing",
      "tag": "",
      "shape": "",
      "material": "per Section 530 Georgia DOT Specifications",
      "count": null,
      "note": "Callout only, not detailed as an item"
    }
  ],
  "measurements": [
    {
      "label": "Width",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "gap at left edge of section"
    },
    {
      "label": "Width",
      "value": "1'-8\"",
      "unit": "ft-in",
      "appliesTo": "left endwall region"
    },
    {
      "label": "Length",
      "value": "34'-0\"",
      "unit": "ft-in",
      "appliesTo": "deck section thru endwall span"
    },
    {
      "label": "Width",
      "value": "6'-8\"",
      "unit": "ft-in",
      "appliesTo": "right side of deck near endwall"
    },
    {
      "label": "Width",
      "value": "1'-1\"",
      "unit": "ft-in",
      "appliesTo": "right edge of section"
    },
    {
      "label": "Height",
      "value": "3'-6\"",
      "unit": "ft-in",
      "appliesTo": "right endwall parapet height"
    },
    {
      "label": "Slope",
      "value": "2%",
      "unit": "%",
      "appliesTo": "deck cross slope"
    },
    {
      "label": "Gap",
      "value": "1\"",
      "unit": "in",
      "appliesTo": "required construction joint gap, min."
    },
    {
      "label": "Joint filler thickness",
      "value": "1/2\"",
      "unit": "in",
      "appliesTo": "preformed joint filler, typ."
    },
    {
      "label": "Joint filler thickness",
      "value": "1\"",
      "unit": "in",
      "appliesTo": "preformed foam joint filler around pad"
    },
    {
      "label": "Endwall height",
      "value": "3'-0\"",
      "unit": "ft-in",
      "appliesTo": "3'-0\" ENDWALL"
    },
    {
      "label": "Endwall height",
      "value": "1'-6\"",
      "unit": "ft-in",
      "appliesTo": "1'-6\" ENDWALL"
    },
    {
      "label": "Fence fabric interval",
      "value": "14",
      "unit": "in",
      "appliesTo": "fence fastening interval, max"
    },
    {
      "label": "Post spacing minimum",
      "value": "7'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence posts, min."
    },
    {
      "label": "Post spacing maximum",
      "value": "10'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence posts, max."
    },
    {
      "label": "Post offset from joint",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence posts min from barrier joints"
    },
    {
      "label": "Tension bar band spacing",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "tension bar bands o.c. max."
    },
    {
      "label": "Pipe diameter",
      "value": "1 5/8\"",
      "unit": "in",
      "appliesTo": "pipe, zinc coated (fence)"
    },
    {
      "label": "Pipe diameter",
      "value": "2 7/8\"",
      "unit": "in",
      "appliesTo": "pipe, typ. (fence posts)"
    },
    {
      "label": "Offset",
      "value": "1/2\"",
      "unit": "in",
      "appliesTo": "offset dimension in fence elevation"
    },
    {
      "label": "Distance",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "end post/const joint spacing"
    },
    {
      "label": "Radius",
      "value": "2'-6\"",
      "unit": "ft-in",
      "appliesTo": "fence post curve radius"
    },
    {
      "label": "Angle",
      "value": "45°",
      "unit": "degrees",
      "appliesTo": "fence post bend angle"
    },
    {
      "label": "Dimension",
      "value": "10 1/4\"",
      "unit": "in",
      "appliesTo": "fence post detail"
    },
    {
      "label": "Height",
      "value": "5'-1\"",
      "unit": "ft-in",
      "appliesTo": "fence post detail"
    },
    {
      "label": "Height",
      "value": "4'-7\"",
      "unit": "ft-in",
      "appliesTo": "fence post height"
    },
    {
      "label": "Height",
      "value": "10'-4\"",
      "unit": "ft-in",
      "appliesTo": "overall fence post detail height"
    },
    {
      "label": "Fence height",
      "value": "7'-0\"",
      "unit": "ft",
      "appliesTo": "zinc coated fence"
    },
    {
      "label": "Distance",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence post detail lower dimension"
    },
    {
      "label": "Barrier height",
      "value": "3'-6\"",
      "unit": "ft-in",
      "appliesTo": "barrier in fence post detail"
    },
    {
      "label": "Pipe sleeve diameter",
      "value": "4\"",
      "unit": "in",
      "appliesTo": "pipe sleeve, std wt."
    },
    {
      "label": "Clear cover",
      "value": "2\"",
      "unit": "in",
      "appliesTo": "CL. 3 SIDES, section at endwall"
    },
    {
      "label": "Minimum clearance",
      "value": "3 1/2\"",
      "unit": "in",
      "appliesTo": "506B min. clearance"
    },
    {
      "label": "Dimension",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "section at endwall top dimension"
    },
    {
      "label": "Dimension",
      "value": "1'-6\"",
      "unit": "ft-in",
      "appliesTo": "section at endwall dimension"
    },
    {
      "label": "Dimension",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "section at endwall dimension"
    },
    {
      "label": "Dimension",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "section at endwall vertical dimension"
    },
    {
      "label": "Dimension",
      "value": "9\"",
      "unit": "in",
      "appliesTo": "section at endwall vertical dimension"
    },
    {
      "label": "Dimension",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "section at endwall vertical dimension"
    },
    {
      "label": "Dimension",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "section at endwall lower dimension"
    },
    {
      "label": "Spacing",
      "value": "18\"",
      "unit": "in",
      "appliesTo": "506B rebar spacing, approx."
    },
    {
      "label": "Spacing",
      "value": "9\"",
      "unit": "in",
      "appliesTo": "506B alt. spacing to give"
    },
    {
      "label": "Spacing",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "8-504B spacing between beams, approx."
    },
    {
      "label": "Radius",
      "value": "1/4\"",
      "unit": "in",
      "appliesTo": "corner radius, section at endwall"
    },
    {
      "label": "Scale",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "Fence Elevation, Fence Post Detail, Section at Endwall"
    }
  ],
  "notes": [
    "NOTE: BARS 401, 504 SERIES, 505, AND 506 SERIES NOT SHOWN",
    "FENCE NOTES:",
    "1. FENCE SHALL BE 9 GAGE CHAIN LINK ZINC COATED TWO INCH SECURITY FENCE.",
    "2. CAST 4\" DIA. GALVANIZED SLEEVE IN THE PARAPET. ALLOW NON-SHRINK, NON-METALLIC GROUT TO CURE FOR THREE DAYS BEFORE FENCE FABRIC IS INSTALLED.",
    "3. APPLY GALVANIZING REPAIR COMPOUND, IN ACCORDANCE WITH GEORGIA DOT SPECIFICATION 645, TO ENDS OF 4\" DIA. GALVANIZED SLEEVES.",
    "4. PROVIDE EXPANSION SLEEVE FOR ALL RAILS TO MATCH SUPERSTRUCTURE JOINTS.",
    "5. FASTEN FABRIC TO POSTS AT INTERVALS NOT GREATER THAN 14\".",
    "6. SPACE POSTS AT A MINIMUM OF 7'-0\" AND A MAXIMUM OF 10'-0\". PLACE POSTS 1'-0\" MINIMUM FROM JOINTS IN BARRIER. SEE DECK PLAN FOR POST SPACING.",
    "7. FOR FURTHER DETAILS, SEE GEORGIA DOT SPECIFICATIONS SECTIONS 643 AND 894.",
    "WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS",
    "SLAB REINFORCEMENT NOT SHOWN",
    "* NON-SHRINK, NON-METALLIC PORTLAND CEMENT GROUT IN ACCORDANCE WITH ASTM C1107, TROWEL TO PROVIDE POSITIVE DRAINAGE.",
    "END BENT 1 SHOWN, END BENT 4 SIMILAR"
  ],
  "labels": [
    "SECTION THRU ENDWALL",
    "(LOOKING AHEAD, LEFT BRIDGE SHOWN, RIGHT BRIDGE SIMILAR)",
    "SR 21 WB = PGL",
    "FENCE ELEVATION",
    "FENCE POST DETAIL",
    "SECTION AT ENDWALL",
    "SCALE: 3/4\" = 1'-0\"",
    "BARRIER",
    "SLAB",
    "END POST",
    "CONST. JOINT",
    "TENSION BAR ZINC COATED",
    "ZINC COATED FENCE",
    "POST VERT. ZINC COATED",
    "TRUSS BRACING AT END OR PULL",
    "2 7/8\" PULL POST",
    "4\" DIA. STD. WT. PIPE SLEEVE",
    "7'-0\" ZINC COATED FENCE",
    "BEARING NOT SH[OWN]"
  ],
  "description": "This crop contains multiple bridge structural details: a full-width cross section thru an endwall showing girders, deck slab, endwall heights, and joint fillers with rebar marks (4-900A/B); a set of fence notes governing chain link security fence construction; a fence elevation and fence post detail showing pipe post dimensions and bracing; and a section at the endwall (End Bent 1/4) showing reinforcement bars, bearing area (not shown), and waterproofing callout. The sheet appears to document both superstructure endwall/deck geometry and appurtenant fence/security barrier details for a bridge, likely along SR 21."
}

p08_r01Detail

  • Truss bracing×1diagonalzinc coated steelAt end or pull post

1 1/2 in Width1'-8" ft-in Width34'-0" ft-in Length6'-8" ft-in Width1'-1" ft-in Width3'-6" ft-in Height2% % Slope1" in Gap+37 more