The ontology would need a fence-post class.
How the sheets named it
Notes on the sheets that carry it
- p43'-0" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.
- p48" FILLET, TYP.
- p4B.F.P.R. BENT 1
- p412" PAVING REST
- p41'-6" ENDWALL
- p41'-0" EDGEBEAM, TYP.
- p410" CONCRETE DIAPHRAGM, TYP.
- p481°-20'-05.0", TYP.
- p4CONSTRUCTION CL SR 21
- p481°-20'-05.0"
- p4FENCE POST SPACING
- p4END POST
- p52'-0" MIN. LAP
- p6B.F.P.R. BENT 4
- p6CONSTRUCTION ℄ SR 21
- p6PGL WESTBOUND
- p6PGL EASTBOUND
- p6N 83°-43'-21.7" E
- p8NOTE: BARS 401, 504 SERIES, 505, AND 506 SERIES NOT SHOWN
- p8FENCE NOTES:
- p81. FENCE SHALL BE 9 GAGE CHAIN LINK ZINC COATED TWO INCH SECURITY FENCE.
- p82. CAST 4" DIA. GALVANIZED SLEEVE IN THE PARAPET. ALLOW NON-SHRINK, NON-METALLIC GROUT TO CURE FOR THREE DAYS BEFORE FENCE FABRIC IS INSTALLED.
- p83. APPLY GALVANIZING REPAIR COMPOUND, IN ACCORDANCE WITH GEORGIA DOT SPECIFICATION 645, TO ENDS OF 4" DIA. GALVANIZED SLEEVES.
- p84. PROVIDE EXPANSION SLEEVE FOR ALL RAILS TO MATCH SUPERSTRUCTURE JOINTS.
- p85. FASTEN FABRIC TO POSTS AT INTERVALS NOT GREATER THAN 14".
- p86. SPACE POSTS AT A MINIMUM OF 7'-0" AND A MAXIMUM OF 10'-0". PLACE POSTS 1'-0" MINIMUM FROM JOINTS IN BARRIER. SEE DECK PLAN FOR POST SPACING.
- p87. FOR FURTHER DETAILS, SEE GEORGIA DOT SPECIFICATIONS SECTIONS 643 AND 894.
- p8WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS
- p8SLAB REINFORCEMENT NOT SHOWN
- p8END BENT 1 SHOWN, END BENT 4 SIMILAR
- p8* NON-SHRINK, NON-METALLIC PORTLAND CEMENT GROUT IN ACCORDANCE WITH ASTM C1107, TROWEL TO PROVIDE POSITIVE DRAINAGE.
- p8REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.
- p8NOTE: LAP 503A AND 503B BARS A MINIMUM OF 2'-2"
- p8*TAPERS TO 0" AT END POST
- p8FENCE NOT SHOWN, TYP.
- p8503B AT EACH 503A
- p82" CL., TWO SIDES
- p812-502 IN BARRIER, SEE DECK PLAN FOR LETTER DESIGNATION
- p8503A AT 14"
- p8¾" TRIANGULAR DRIP BEAD, FULL LENGTH OF BRIDGE BOTH SIDES
Every crop it was read in — the drawing beside what the model took off it
Page 4
p04_r01 title blockPlan
- Fence post12-502A / 12-502B / 12-502C×9circular (post markers shown as small circles)not statedFence post spacing marks along top and bottom edges of both spans, tagged 502A, 502B, 502C with quantity prefix '12-'
55'-0" ft-in Overall deck width (top span)18'-4" ft-in Segment width9'-6" ft-in Beam spacing6'-6" ft-in End segment1'-0" ft-in Edge offset40'-0" ft-in Gutter to gutter width43'-7" ft-in Out to out width1'-9 1/2" ft-in Offset from gutter to out+27 more
Page 5
p05_r01 out to outPlan
- Fence post spacing (fence line)linear spacing marksMarked along both outer edges of both deck panels with 3'-0"/9'-6" spacing pattern
82'-0" ft-in Overall deck length82'-0" ft-in Overall deck length16'-4 1/2" ft-in Bay spacing16'-6" ft-in End bay spacing9'-6" ft-in Sub-spacing9'-10 1/2" ft-in Sub-spacing3'-0" ft-in Edge offset2'-0" ft-in Edge offset+12 more
p05_r01Plan
- fence postonly spacing dimensions shown, posts themselves not drawn; labeled 'FENCE POST SPACING'
82'-0" overall deck width16'-4 1/2" panel spacing16'-6" end panel spacing9'-6" sub-spacing9'-10 1/2" sub-spacing (alt row)3'-0" end offset2'-0" end offset (alt)1'-0" end offset (alt)+12 more
Page 6
p06_r01 title blockPlan
- Fence post spacing markerspoint markersRows of dimensioned spacing along both outer edges and inner edges of both deck halves; some marked with * and ** symbols
55'-0" Overall deck width, top deck18'-4" Beam bay spacing (3 bays)6'-6", 9'-6", 9'-6", 9'-6", 9'-6", 9'-6" Fence post spacing sequence1'-0" End dimension81°-20'-05.0" Skew angle10" Diaphragm thickness8" Fillet dimension1'-0" Edgebeam width+20 more
p06_r01Plan
- Fence post spacing markers*Asterisk symbols denote fence post spacing locations, referenced but not individually described.
55'-0" ft-in Overall deck width18'-4" ft-in Segment width6'-6" ft-in Fence post spacing9'-6" ft-in Fence post spacing1'-0" ft-in Fence post spacing (end)5'-0" ft-in Post bracket spacing81°-20'-05.0" degrees-min-sec Skew angle10" in Diaphragm thickness+33 more
Page 8
p08_r01 for further details see georgia dot specDetail
- Pull post (fence)×12 7/8" dia pipezinc coated steel
- Fence post (typical vertical)2 7/8" dia pipe, curved top 45°zinc coated steelPost spaced per Fence Notes 6, curved top detail with 2'-6" R
1 1/2 in Overhang width1'-8" ft-in Width34'-0" ft-in Width6'-8" ft-in Width1'-1" ft-in Width3'-6" ft-in Barrier height at right2 % Cross slope1 in Gap min.+36 more
p08_r01Detail
- Fence post×1pipe, curved topzinc coated steel2 7/8" dia. pipe pull post with truss bracing
1 1/2 in Width1'-8" ft-in Width34'-0" ft-in Length6'-8" ft-in Width1'-1" ft-in Width3'-6" ft-in Height2% % Slope1" in Gap+37 more
p08_r02Detail
- Fence (post)Not shown in this detail, typical callout only
2'-2" ft-in Lap length1'-9 1/2" ft-in Top width8" in Sub-width1'-0" ft-in Sub-width1 1/2" in Clear cover3" in Clear cover2" in Clear cover, two sides3'-6" ft-in Barrier height+5 more