Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Diaphragm

7 pages · 16 crops · ×45 · superstructure

Matched toDiaphragmbridge.superstructure.secondary_member_system.diaphragmon “Diaphragm

1 read off the drawings · 4 not established
The class asks forValueHowFrom
LengthLwants m/mmnot establishedThe diaphragm details show differing overall heights: 2'-4" on page 7 and 3'-0" on page 9. The readings do not establish which, if either, is the Length required for the marked item 400A; 400A is identified elsewhere as deck reinforcement rather than the concrete diaphragm.not found
Cross-sectional AreaAwants m2/mm2not establishedA 10" diaphragm width is stated, but the associated diaphragm depth is not uniquely established for item 400A: page 7 shows 2'-4" overall beam/diaphragm-section height, while page 9 shows 3'-0" diaphragm-section overall depth. Therefore a single cross-sectional area cannot be derived honestly.not found
Instance CountNwants countnot establishedThe plan readings provide conflicting diaphragm counts: 3 on page 4, 2 on page 5, and 6 on page 6. In addition, the 400A mark is described in section readings as reinforcement steel, not as the concrete diaphragm. No unambiguous total count for diaphragm item 400A is established.not found
Material TypeMATreinforced concrete -The deck plan identifies the concrete diaphragm as reinforced concrete, and the diaphragm detail also identifies it as reinforced concrete.readp4 · p04_r01 title blockp7 · p07_r04 1 cl typ
MassMwants kg/tnot establishedNo diaphragm mass, volume, density, or concrete quantity from which mass could be derived is stated in the readings.not found

Worked out by openai/gpt-5.6-terra-pro from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

How the sheets named it

Concrete diaphragmconcrete diaphragmBeam / diaphragm concrete section400A

Every dimension read for it3

  • 10"Diaphragm thicknessp6 · p06_r01 title block
  • 10 inDiaphragm widthp7 · p07_r04 1 cl typ
  • 10" inDiaphragm widthp7 · p07_r04

Notes on the sheets that carry it

  • p2STEEL DIAPHRAGMS - AT CONTRACTOR'S OPTION, STEEL DIAPHRAGMS MAY BE USED IN LIEU OF THE CONCRETE DIAPHRAGMS SHOWN IN THE PLANS.
  • p2AT A MINIMUM, STEEL DIAPHRAGMS ARE TO BE DESIGNED AT STRENGTH LIMIT STATE III WITH A THREE SECOND GUST WIND SPEED OF 140MPH APPLIED TO ONE HALF OF THE VERTICAL SURFACE AREA OF THE EXPOSED BEAM USING EXPOSURE CATEGORY D.
  • p2CROSS FRAME CONFIGURATIONS SHALL HAVE A HORIZONTAL ANGLE OR CHANNEL AT EITHER THE TOP OR BOTTOM POSITION.
  • p2STEEL DIAPHRAGMS SHALL BE MANUFACTURED BY A FABRICATOR LISTED ON QPL 60 PER SECTION 501 OR GREATER STEEL.
  • p2ALL COMPONENTS OF THE STEEL DIAPHRAGM SHALL BE GALVANIZED ACCORDING TO ASTM A123.
  • p2CONNECTION BOLTS SHALL CONFORM TO ASTM F3125 (GRADE A325).
  • p2NUTS SHALL CONFORM TO ASTM A563.
  • p2WASHERS SHALL CONFORM TO ASTM F436.
  • p2ALL HARDWARE SHALL BE GALVANIZED ACCORDING TO ASTM A153.
  • p2STABILITY OF THE BEAMS AND STRUCTURE DURING ALL PHASES OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
  • p2SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR THE STEEL DIAPHRAGMS TO THE ENGINEER FOR REVIEW AND ACCEPTANCE.
  • p2THE USE OF STEEL DIAPHRAGMS SHALL BE INCLUDED IN THE PRICE BID FOR "LUMP-SUPESTR CONCRETE."
  • p43'-0" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.
  • p48" FILLET, TYP.
  • p4B.F.P.R. BENT 1
  • p412" PAVING REST
  • p41'-6" ENDWALL
  • p41'-0" EDGEBEAM, TYP.
  • p410" CONCRETE DIAPHRAGM, TYP.
  • p481°-20'-05.0", TYP.
  • p4CONSTRUCTION CL SR 21
  • p481°-20'-05.0"
  • p4FENCE POST SPACING
  • p4END POST
  • p52'-0" MIN. LAP
  • p6B.F.P.R. BENT 4
  • p6CONSTRUCTION ℄ SR 21
  • p6PGL WESTBOUND
  • p6PGL EASTBOUND
  • p6N 83°-43'-21.7" E
  • p7DIMENSION "D" IS MEASURED FROM TOP OF SLAB TO TOP OF BEAMS AT CENTERLINE BEARING. VARY "D" BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTION, AND VERTICAL CURVE.
  • p7MAINTAIN A CONSTANT SLAB THICKNESS OF 7 3/4" BETWEEN BEAMS AND 8" IN THE OVERHANGS.
  • p7"D" = 8 3/4" INTERIOR BEAMS
  • p7"D" = 9 1/8" EXTERIOR BEAMS
  • p7FENCE NOT SHOWN, TYP.
  • p7502 AT EVERY 500A, TYP.
  • p730-400A SPACED AS SHOWN
  • p7500A AT 6 1/2"
  • p7501 UNDER EVERY 500A
  • p7REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.

Every crop it was read in — the drawing beside what the model took off it

Page 2

crop

p02_r07 listed on qpl 60 per section 501 or grea

page 2 · gdot_plan_649084f395824aaebf1f5ed48132696f_p02_r07_listed_on_qpl_60_per_section_501_or_grea
Original
p02_r07 listed on qpl 60 per section 501 or grea
{
  "view": "Notes",
  "objects": [
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "",
      "material": "structural steel (alternative) / concrete (as shown in plans)",
      "count": null,
      "note": "Steel diaphragms may be substituted for concrete diaphragms at contractor's option, subject to design and material requirements stated in the note."
    }
  ],
  "measurements": [
    {
      "label": "three second gust wind speed",
      "value": "140",
      "unit": "MPH",
      "appliesTo": "steel diaphragm design"
    }
  ],
  "notes": [
    "STEEL DIAPHRAGMS - AT CONTRACTOR'S OPTION, STEEL DIAPHRAGMS MAY BE USED IN LIEU OF THE CONCRETE DIAPHRAGMS SHOWN IN THE PLANS.",
    "AT A MINIMUM, STEEL DIAPHRAGMS ARE TO BE DESIGNED AT STRENGTH LIMIT STATE III WITH A THREE SECOND GUST WIND SPEED OF 140MPH APPLIED TO ONE HALF OF THE VERTICAL SURFACE AREA OF THE EXPOSED BEAM USING EXPOSURE CATEGORY D.",
    "CROSS FRAME CONFIGURATIONS SHALL HAVE A HORIZONTAL ANGLE OR CHANNEL AT EITHER THE TOP OR BOTTOM POSITION.",
    "STEEL DIAPHRAGMS SHALL BE MANUFACTURED BY A FABRICATOR LISTED ON QPL 60 PER SECTION 501 OR GREATER STEEL.",
    "ALL COMPONENTS OF THE STEEL DIAPHRAGM SHALL BE GALVANIZED ACCORDING TO ASTM A123.",
    "CONNECTION BOLTS SHALL CONFORM TO ASTM F3125 (GRADE A325).",
    "NUTS SHALL CONFORM TO ASTM A563.",
    "WASHERS SHALL CONFORM TO ASTM F436.",
    "ALL HARDWARE SHALL BE GALVANIZED ACCORDING TO ASTM A153.",
    "STABILITY OF THE BEAMS AND STRUCTURE DURING ALL PHASES OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.",
    "SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR THE STEEL DIAPHRAGMS TO THE ENGINEER FOR REVIEW AND ACCEPTANCE.",
    "THE USE OF STEEL DIAPHRAGMS SHALL BE INCLUDED IN THE PRICE BID FOR \"LUMP-SUPESTR CONCRETE.\""
  ],
  "labels": [],
  "description": "This crop is a block of specification notes concerning steel diaphragms as an alternative to concrete diaphragms in the superstructure design. It specifies design criteria (wind load, strength limit state), material and hardware standards (ASTM specifications for bolts, nuts, washers, galvanizing), fabrication qualification requirements, and contractual/administrative requirements (shop drawing submittal, bid item inclusion). No graphical elements, dimensions, or drawn objects are shown—only text notes."
}

p02_r07 listed on qpl 60 per section 501 or greaNotes

  • Diaphragmstructural steel (alternative) / concrete (as shown in plans)Steel diaphragms may be substituted for concrete diaphragms at contractor's option, subject to design and material requirements stated in the note.

140 MPH three second gust wind speed

Page 4

crop

p04_r01 title block

page 4 · gdot_plan_649084f395824aaebf1f5ed48132696f_p04_r01_title_block
Original
p04_r01 title block
{
  "view": "Plan",
  "objects": [
    {
      "name": "Beam",
      "tag": "BEAM 1-6 (Westbound span)",
      "shape": "linear/I-shaped (beam line)",
      "material": "precast concrete (implied by 400A callout)",
      "count": 6,
      "note": "Centerlines shown as dash-dot lines, beams 1 through 6 for westbound deck"
    },
    {
      "name": "Beam",
      "tag": "BEAM 7-12 (Eastbound span)",
      "shape": "linear/I-shaped (beam line)",
      "material": "precast concrete (implied by 400A callout)",
      "count": 6,
      "note": "Centerlines shown as dash-dot lines, beams 7 through 12 for eastbound deck"
    },
    {
      "name": "Diaphragm",
      "tag": "400A",
      "shape": "rectangular strip, perpendicular to beams",
      "material": "reinforced concrete",
      "count": 3,
      "note": "Labeled '10\" CONCRETE DIAPHRAGM, TYP.', shown crossing beams at intervals, callout '400A' repeated twice (once per span)"
    },
    {
      "name": "Edgebeam",
      "tag": "",
      "shape": "linear strip along deck edge",
      "material": "concrete",
      "count": 2,
      "note": "1'-0\" EDGEBEAM, TYP., one along each side of each span"
    },
    {
      "name": "Fillet",
      "tag": "",
      "shape": "linear strip",
      "material": "concrete",
      "count": 4,
      "note": "8\" FILLET, TYP., shown along beam edges"
    },
    {
      "name": "Endwall",
      "tag": "",
      "shape": "linear/rectangular",
      "material": "concrete",
      "count": 4,
      "note": "Two types called out: '3'-0\" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.' and '1'-6\" ENDWALL'"
    },
    {
      "name": "Paving rest",
      "tag": "",
      "shape": "ledge/rectangular",
      "material": "concrete",
      "count": 2,
      "note": "12\" PAVING REST, TYP., one per span at bent location"
    },
    {
      "name": "Bent",
      "tag": "BENT 1 (B.F.P.R. BENT 1)",
      "shape": "not fully shown, referenced at edge of plan",
      "material": "concrete",
      "count": 2,
      "note": "Labeled 'B.F.P.R. BENT 1' appears at both spans, likely 'Back Face Paving Rest' or bent reference; only tag visible, structure not detailed in this crop"
    },
    {
      "name": "Fence post",
      "tag": "12-502A / 12-502B / 12-502C",
      "shape": "circular (post markers shown as small circles)",
      "material": "not stated",
      "count": 9,
      "note": "Fence post spacing marks along top and bottom edges of both spans, tagged 502A, 502B, 502C with quantity prefix '12-'"
    },
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "rectangular/trapezoidal (skewed)",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Two deck panels shown, Westbound and Eastbound, both skewed at 81°-20'-05.0\""
    }
  ],
  "measurements": [
    {
      "label": "Overall deck width (top span)",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck top edge"
    },
    {
      "label": "Segment width",
      "value": "18'-4\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck top edge (3 segments)"
    },
    {
      "label": "Beam spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck top edge beam spacing (5 instances)"
    },
    {
      "label": "End segment",
      "value": "6'-6\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck top edge end segment"
    },
    {
      "label": "Edge offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck top edge start offset"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "ft-in",
      "appliesTo": "Deck cross width, both spans"
    },
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "ft-in",
      "appliesTo": "Deck cross width, both spans"
    },
    {
      "label": "Offset from gutter to out",
      "value": "1'-9 1/2\"",
      "unit": "ft-in",
      "appliesTo": "Deck edge, both spans (4 instances)"
    },
    {
      "label": "Fence post spacing width",
      "value": "5'-0\"",
      "unit": "ft-in",
      "appliesTo": "Fence posts near edgebeam ends, both spans (4 instances)"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "degrees-min-sec",
      "appliesTo": "Beam skew / construction centerline skew, multiple callouts"
    },
    {
      "label": "Bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "bearing",
      "appliesTo": "Construction reference line between spans"
    },
    {
      "label": "Fillet thickness",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "Fillet, typ."
    },
    {
      "label": "Diaphragm thickness",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "Concrete diaphragm, typ."
    },
    {
      "label": "Edgebeam width",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Edgebeam, typ."
    },
    {
      "label": "Endwall thickness (exterior)",
      "value": "3'-0\"",
      "unit": "ft-in",
      "appliesTo": "Endwall outside exterior beam, typ."
    },
    {
      "label": "Endwall thickness (interior)",
      "value": "1'-6\"",
      "unit": "ft-in",
      "appliesTo": "Endwall"
    },
    {
      "label": "Paving rest width",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "Paving rest"
    },
    {
      "label": "Bottom span width dimension set",
      "value": "22'-0\"",
      "unit": "ft-in",
      "appliesTo": "Vertical dimension between spans (2 instances)"
    },
    {
      "label": "Lower fence post spacing overall (bottom of westbound)",
      "value": "52'-2 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck bottom edge overall"
    },
    {
      "label": "Segment dimension",
      "value": "17'-4 5/16\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck bottom edge segment"
    },
    {
      "label": "Segment dimension",
      "value": "17'-5 1/4\"",
      "unit": "ft-in",
      "appliesTo": "Westbound deck bottom edge segment (2 instances)"
    },
    {
      "label": "End post dimension",
      "value": "4'-3\"",
      "unit": "ft-in",
      "appliesTo": "End post, westbound bottom edge"
    },
    {
      "label": "Fence post spacing segments (bottom westbound)",
      "value": "8'-9\", 8'-9\", 8'-0\", 9'-6\", 9'-6\", 6'-8 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Westbound bottom edge fence post spacing"
    },
    {
      "label": "Offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound bottom edge start offset"
    },
    {
      "label": "Eastbound top edge overall",
      "value": "51'-8 3/8\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck top edge overall"
    },
    {
      "label": "Segment dimension",
      "value": "17'-2 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck top edge segment (2 instances)"
    },
    {
      "label": "Segment dimension",
      "value": "17'-2 3/4\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck top edge segment"
    },
    {
      "label": "End post dimension",
      "value": "4'-6\"",
      "unit": "ft-in",
      "appliesTo": "End post, eastbound top edge"
    },
    {
      "label": "Fence post spacing segments (top eastbound)",
      "value": "8'-9\", 8'-9\", 8'-0\", 9'-6\", 9'-6\", 6'-2 3/8\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound top edge fence post spacing"
    },
    {
      "label": "Offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound top edge start offset"
    },
    {
      "label": "Overall deck width (bottom span)",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck bottom edge"
    },
    {
      "label": "Segment width",
      "value": "18'-4\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck bottom edge (3 segments)"
    },
    {
      "label": "Beam spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck bottom edge beam spacing (5 instances)"
    },
    {
      "label": "End segment",
      "value": "6'-6\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck bottom edge end segment"
    },
    {
      "label": "Offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound deck bottom edge start offset"
    }
  ],
  "notes": [
    "3'-0\" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.",
    "8\" FILLET, TYP.",
    "B.F.P.R. BENT 1",
    "12\" PAVING REST",
    "1'-6\" ENDWALL",
    "1'-0\" EDGEBEAM, TYP.",
    "10\" CONCRETE DIAPHRAGM, TYP.",
    "81°-20'-05.0\", TYP.",
    "CONSTRUCTION CL SR 21",
    "81°-20'-05.0\"",
    "FENCE POST SPACING",
    "END POST"
  ],
  "labels": [
    "DECK PLAN",
    "SPAN 1",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "12-502A",
    "12-502B",
    "12-502C",
    "400A",
    "N 83°-43'-21.7\" E",
    "aruna sastry",
    "5/31/2025",
    "11:05:27 AM"
  ],
  "description": "This crop is a Deck Plan (Span 1) for a two-span bridge structure, showing separate westbound and eastbound decks in plan view, each skewed at 81°-20'-05.0\". It details beam centerlines (Beam 1-12), fence post spacing and tags (502A/B/C), edgebeams, fillets, endwalls, paving rests, concrete diaphragms (400A), and overall/segment dimensions for deck width, gutter-to-gutter and out-to-out widths, plus a construction centerline (SR 21) and bearing reference between the two spans."
}

p04_r01 title blockPlan

  • Diaphragm400A×3rectangular strip, perpendicular to beamsreinforced concreteLabeled '10" CONCRETE DIAPHRAGM, TYP.', shown crossing beams at intervals, callout '400A' repeated twice (once per span)

55'-0" ft-in Overall deck width (top span)18'-4" ft-in Segment width9'-6" ft-in Beam spacing6'-6" ft-in End segment1'-0" ft-in Edge offset40'-0" ft-in Gutter to gutter width43'-7" ft-in Out to out width1'-9 1/2" ft-in Offset from gutter to out+27 more

crop

p04_r01

page 4 · other_p04_r01
Original
p04_r01
{
  "view": "Plan",
  "objects": [
    {
      "name": "Deck slab",
      "tag": "SPAN 1",
      "shape": "trapezoidal (skewed)",
      "material": "reinforced concrete",
      "count": 2,
      "note": "One deck plan shown for each bridge (westbound and eastbound), both labeled Span 1"
    },
    {
      "name": "Beam",
      "tag": "BEAM 1–BEAM 12",
      "shape": "longitudinal, parallel",
      "material": "precast/prestressed concrete (implied by beam callouts, not stated)",
      "count": 12,
      "note": "Six beams shown per bridge, centerlines labeled CL BEAM 1 through CL BEAM 12"
    },
    {
      "name": "Endwall",
      "tag": "",
      "shape": "linear, at ends of span",
      "material": "concrete",
      "count": 4,
      "note": "Two sizes noted: 3'-0\" endwall outside exterior beam (typ.) and 1'-6\" endwall"
    },
    {
      "name": "Edgebeam",
      "tag": "",
      "shape": "linear, along deck edge",
      "material": "concrete",
      "count": 2,
      "note": "1'-0\" edgebeam, typ., one per bridge"
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "transverse, rectangular",
      "material": "concrete",
      "count": 6,
      "note": "10\" concrete diaphragm, typ.; three transverse lines shown per bridge deck"
    },
    {
      "name": "Paving rest",
      "tag": "",
      "shape": "linear ledge",
      "material": "concrete",
      "count": 2,
      "note": "12\" paving rest, one per bridge at bent end"
    },
    {
      "name": "Bent",
      "tag": "B.F.P.R. BENT 1",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "Referenced as back face of bent (B.F.P.R.), one per bridge deck plan"
    },
    {
      "name": "End post",
      "tag": "END POST",
      "shape": "",
      "material": "concrete",
      "count": 2,
      "note": "Located at the skewed end of each span, dimensioned 4'-3\" and 4'-6\""
    },
    {
      "name": "Reinforcement bar",
      "tag": "12-502A",
      "shape": "bar, transverse",
      "material": "reinforcing steel",
      "count": 6,
      "note": "Shown at top and bottom edges of both bridge decks"
    },
    {
      "name": "Reinforcement bar",
      "tag": "12-502B",
      "shape": "bar, transverse",
      "material": "reinforcing steel",
      "count": 3,
      "note": "Shown along lower edge of upper (westbound) deck"
    },
    {
      "name": "Reinforcement bar",
      "tag": "12-502C",
      "shape": "bar, transverse",
      "material": "reinforcing steel",
      "count": 3,
      "note": "Shown along upper edge of lower (eastbound) deck"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400A",
      "shape": "bar, longitudinal",
      "material": "reinforcing steel",
      "count": 2,
      "note": "Labeled once per deck, appears to run along beam lines"
    }
  ],
  "measurements": [
    {
      "label": "Overall deck width",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Span 1 deck (both bridges)"
    },
    {
      "label": "Panel spacing",
      "value": "18'-4\"",
      "unit": "ft-in",
      "appliesTo": "Deck panel spacing, repeated 3x per deck"
    },
    {
      "label": "Bar spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "12-502A/B/C bar spacing, repeated multiple times"
    },
    {
      "label": "End spacing",
      "value": "6'-6\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing at deck end"
    },
    {
      "label": "Edge offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Deck edge dimension, multiple locations"
    },
    {
      "label": "Bearing pad spacing",
      "value": "5'-0\"",
      "unit": "ft-in",
      "appliesTo": "Bearing marks (*) near beam ends, x2"
    },
    {
      "label": "Fillet thickness",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "Fillet, typ."
    },
    {
      "label": "Diaphragm thickness",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "Concrete diaphragm, typ."
    },
    {
      "label": "Paving rest width",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "Paving rest"
    },
    {
      "label": "Endwall thickness",
      "value": "3'-0\"",
      "unit": "ft-in",
      "appliesTo": "Endwall outside exterior beam, typ."
    },
    {
      "label": "Endwall thickness",
      "value": "1'-6\"",
      "unit": "ft-in",
      "appliesTo": "Endwall"
    },
    {
      "label": "Edgebeam width",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Edgebeam, typ."
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "ft-in",
      "appliesTo": "Deck cross width"
    },
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "ft-in",
      "appliesTo": "Deck cross width"
    },
    {
      "label": "Overhang dimension",
      "value": "1'-9 1/2\"",
      "unit": "ft-in",
      "appliesTo": "Deck overhang, repeated top and bottom"
    },
    {
      "label": "Distance",
      "value": "22'-0\"",
      "unit": "ft-in",
      "appliesTo": "Between gutter lines, both bridges"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "deg-min-sec",
      "appliesTo": "Beam/skew angle, typ., repeated multiple times"
    },
    {
      "label": "Bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "Construction bearing line"
    },
    {
      "label": "End post dimension",
      "value": "4'-3\"",
      "unit": "ft-in",
      "appliesTo": "End post, upper deck"
    },
    {
      "label": "End post dimension",
      "value": "4'-6\"",
      "unit": "ft-in",
      "appliesTo": "End post, lower deck"
    },
    {
      "label": "Diagonal dimension",
      "value": "17'-4 5/16\"",
      "unit": "ft-in",
      "appliesTo": "Skewed deck edge segment"
    },
    {
      "label": "Diagonal dimension",
      "value": "17'-5 1/4\"",
      "unit": "ft-in",
      "appliesTo": "Skewed deck edge segment, x2"
    },
    {
      "label": "Total diagonal dimension",
      "value": "52'-2 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Skewed deck edge total, upper deck"
    },
    {
      "label": "Diagonal dimension",
      "value": "17'-2 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Skewed deck edge segment, lower deck, x2"
    },
    {
      "label": "Diagonal dimension",
      "value": "17'-2 3/4\"",
      "unit": "ft-in",
      "appliesTo": "Skewed deck edge segment, lower deck"
    },
    {
      "label": "Total diagonal dimension",
      "value": "51'-8 3/8\"",
      "unit": "ft-in",
      "appliesTo": "Skewed deck edge total, lower deck"
    },
    {
      "label": "Fence post spacing",
      "value": "8'-9\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing, repeated multiple times"
    },
    {
      "label": "Fence post spacing",
      "value": "8'-0\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing, x2"
    },
    {
      "label": "Fence post spacing",
      "value": "6'-8 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing, upper deck end"
    },
    {
      "label": "Fence post spacing",
      "value": "6'-2 3/8\"",
      "unit": "ft-in",
      "appliesTo": "Fence post spacing, lower deck end"
    }
  ],
  "notes": [],
  "labels": [
    "DECK PLAN",
    "SPAN 1",
    "CONSTRUCTION CL SR 21",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "FENCE POST SPACING",
    "END POST",
    "B.F.P.R. BENT 1",
    "CL BEAM 1",
    "CL BEAM 2",
    "CL BEAM 3",
    "CL BEAM 4",
    "CL BEAM 5",
    "CL BEAM 6",
    "CL BEAM 7",
    "CL BEAM 8",
    "CL BEAM 9",
    "CL BEAM 10",
    "CL BEAM 11",
    "CL BEAM 12"
  ],
  "description": "This crop shows the Deck Plan for Span 1 of a twin-bridge structure, depicting the westbound and eastbound decks side by side with beam centerlines (Beams 1–12), endwalls, edgebeams, diaphragms, paving rests, and end posts. It is heavily dimensioned with panel widths, skew angles (81°-20'-05.0\"), fence post spacing, and gutter-to-gutter/out-to-out widths, and references reinforcing bar marks 12-502A/B/C and 400A along with a construction centerline (SR 21) and bearing call-out."
}

p04_r01Plan

  • Diaphragm×6transverse, rectangularconcrete10" concrete diaphragm, typ.; three transverse lines shown per bridge deck

55'-0" ft-in Overall deck width18'-4" ft-in Panel spacing9'-6" ft-in Bar spacing6'-6" ft-in End spacing1'-0" ft-in Edge offset5'-0" ft-in Bearing pad spacing8" in Fillet thickness10" in Diaphragm thickness+22 more

Page 5

crop

p05_r01 out to out

page 5 · gdot_plan_649084f395824aaebf1f5ed48132696f_p05_r01_out_to_out
Original
p05_r01 out to out
{
  "view": "Plan",
  "objects": [
    {
      "name": "Bridge deck (beam bay)",
      "tag": "",
      "shape": "trapezoidal/skewed rectangular",
      "material": "concrete deck slab",
      "count": 2,
      "note": "Two adjacent skewed deck plan panels shown, upper (westbound) and lower (eastbound), each 82'-0\" long with 12 beams total, 6 per panel"
    },
    {
      "name": "Beam",
      "tag": "BEAM 1",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": "Centerline of beam shown as dashed line, upper panel"
    },
    {
      "name": "Beam",
      "tag": "BEAM 2",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 3",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 4",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 5",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 6",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 7",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": "Lower panel, eastbound"
    },
    {
      "name": "Beam",
      "tag": "BEAM 8",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 9",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 10",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 11",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Beam",
      "tag": "BEAM 12",
      "shape": "straight, parallel line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Concrete diaphragm",
      "tag": "",
      "shape": "transverse strip, rectangular in plan",
      "material": "concrete",
      "count": 2,
      "note": "Shown as \"10\" CONCRETE DIAPHRAGM, TYP.\" crossing beams in both deck panels"
    },
    {
      "name": "Edgebeam",
      "tag": "",
      "shape": "linear strip along deck edge",
      "material": "concrete (implied)",
      "count": 4,
      "note": "1'-0\" EDGEBEAM, TYP., along outer edges of both deck panels"
    },
    {
      "name": "Fillet",
      "tag": "",
      "shape": "linear strip",
      "material": "concrete (implied)",
      "count": 4,
      "note": "8\" FILLET, TYP., shown at beam-deck edge transitions"
    },
    {
      "name": "Reinforcement bar",
      "tag": "12-502D",
      "shape": "bent bar, hooked end shown in plan",
      "material": "reinforcing steel",
      "count": 8,
      "note": "Repeated transverse bars along both top and bottom deck edges of each panel"
    },
    {
      "name": "Reinforcement bar",
      "tag": "12-502E",
      "shape": "bent bar, hooked end shown in plan",
      "material": "reinforcing steel",
      "count": 4,
      "note": "End bar at edge of fence post spacing zone, both panels"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400B",
      "shape": "straight longitudinal bar",
      "material": "reinforcing steel",
      "count": 2,
      "note": "Longitudinal bar shown within deck panel, one callout per panel"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400C",
      "shape": "straight longitudinal bar with lap splice",
      "material": "reinforcing steel",
      "count": 2,
      "note": "Shown with 2'-0\" MIN. LAP callout, one per panel"
    },
    {
      "name": "Fence post spacing (fence line)",
      "tag": "",
      "shape": "linear spacing marks",
      "material": "",
      "count": null,
      "note": "Marked along both outer edges of both deck panels with 3'-0\"/9'-6\" spacing pattern"
    }
  ],
  "measurements": [
    {
      "label": "Overall deck length",
      "value": "82'-0\"",
      "unit": "ft-in",
      "appliesTo": "upper panel (westbound)"
    },
    {
      "label": "Overall deck length",
      "value": "82'-0\"",
      "unit": "ft-in",
      "appliesTo": "lower panel (eastbound)"
    },
    {
      "label": "Bay spacing",
      "value": "16'-4 1/2\"",
      "unit": "ft-in",
      "appliesTo": "upper and lower panels, repeated 4 times"
    },
    {
      "label": "End bay spacing",
      "value": "16'-6\"",
      "unit": "ft-in",
      "appliesTo": "end bay, both panels"
    },
    {
      "label": "Sub-spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "top and bottom edge dimension lines, both panels"
    },
    {
      "label": "Sub-spacing",
      "value": "9'-10 1/2\"",
      "unit": "ft-in",
      "appliesTo": "inner dimension lines near beams, both panels"
    },
    {
      "label": "Edge offset",
      "value": "3'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence post spacing start/end, outer edges"
    },
    {
      "label": "Edge offset",
      "value": "2'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence post spacing inner edge, both panels"
    },
    {
      "label": "Edge offset",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "fence post spacing inner edge, both panels"
    },
    {
      "label": "Fence post spacing gap",
      "value": "5'-0\"",
      "unit": "ft-in",
      "appliesTo": "paired spacing marks at both ends of upper and lower panels"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "construction centerline SR 21 / beam skew, typical"
    },
    {
      "label": "Bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "centerline reference between panels"
    },
    {
      "label": "Diaphragm thickness",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "concrete diaphragm, typical"
    },
    {
      "label": "Fillet dimension",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "fillet, typical"
    },
    {
      "label": "Edgebeam width",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "edgebeam, typical"
    },
    {
      "label": "Lap length",
      "value": "2'-0\"",
      "unit": "ft-in",
      "appliesTo": "400C bar minimum lap"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "ft-in",
      "appliesTo": "deck cross width, both panels"
    },
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "ft-in",
      "appliesTo": "deck cross width, both panels"
    },
    {
      "label": "Edge dimension",
      "value": "1'-9 1/2\"",
      "unit": "ft-in",
      "appliesTo": "outer edge to gutter line, both panels"
    },
    {
      "label": "Half-width dimension",
      "value": "22'-0\"",
      "unit": "ft-in",
      "appliesTo": "centerline to gutter, both panels"
    }
  ],
  "notes": [
    "8\" FILLET, TYP.",
    "1'-0\" EDGEBEAM, TYP.",
    "10\" CONCRETE DIAPHRAGM, TYP.",
    "2'-0\" MIN. LAP",
    "81°-20'-05.0\", TYP.",
    "FENCE POST SPACING"
  ],
  "labels": [
    "SPAN 2",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "CONSTRUCTION ℄ SR 21"
  ],
  "description": "This crop is a plan view of Span 2 of a bridge deck, showing two adjacent skewed deck panels (westbound and eastbound roadways) each 82'-0\" long and containing six precast beams (Beams 1-6 upper, 7-12 lower). It details deck reinforcement bar marks (12-502D, 12-502E, 400B, 400C), edgebeam and fillet callouts, concrete diaphragm locations, fence post spacing along the deck edges, and overall/partial transverse dimensions (gutter-to-gutter, out-to-out) along with the roadway skew angle and centerline bearing."
}

p05_r01 out to outPlan

  • Concrete diaphragm×2transverse strip, rectangular in planconcreteShown as "10" CONCRETE DIAPHRAGM, TYP." crossing beams in both deck panels

82'-0" ft-in Overall deck length82'-0" ft-in Overall deck length16'-4 1/2" ft-in Bay spacing16'-6" ft-in End bay spacing9'-6" ft-in Sub-spacing9'-10 1/2" ft-in Sub-spacing3'-0" ft-in Edge offset2'-0" ft-in Edge offset+12 more

crop

p05_r01

page 5 · other_p05_r01
Original
p05_r01
{
  "view": "Plan",
  "objects": [
    {
      "name": "beam",
      "tag": "BEAM 1 through BEAM 12",
      "shape": "straight, skewed at ends",
      "material": "",
      "count": 12,
      "note": "centerlines shown for each beam, in two groups of six (westbound and eastbound decks)"
    },
    {
      "name": "deck slab",
      "tag": "",
      "shape": "trapezoidal/skewed rectangular",
      "material": "concrete",
      "count": 2,
      "note": "one deck panel per roadway (PGL Westbound and PGL Eastbound), each spanning between skewed end lines"
    },
    {
      "name": "concrete diaphragm",
      "tag": "",
      "shape": "transverse strip",
      "material": "concrete",
      "count": null,
      "note": "labeled '10\" CONCRETE DIAPHRAGM, TYP.' at multiple locations between beams"
    },
    {
      "name": "edge beam",
      "tag": "",
      "shape": "linear strip along deck edge",
      "material": "concrete",
      "count": 4,
      "note": "labeled '1'-0\" EDGEBEAM, TYP.' along outer edges of both decks"
    },
    {
      "name": "fillet",
      "tag": "",
      "shape": "linear strip",
      "material": "concrete",
      "count": 4,
      "note": "labeled '8\" FILLET, TYP.' along beam edges"
    },
    {
      "name": "reinforcement bar",
      "tag": "502D",
      "shape": "bar, bent detail shown",
      "material": "reinforcement steel",
      "count": 8,
      "note": "top transverse bars along deck edges, spaced between beam groups"
    },
    {
      "name": "reinforcement bar",
      "tag": "502E",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": 4,
      "note": "end bars at outer edges of deck, near fence post spacing zones"
    },
    {
      "name": "reinforcement bar",
      "tag": "400B",
      "shape": "bar, longitudinal",
      "material": "reinforcement steel",
      "count": 2,
      "note": "longitudinal bar labeled '400B' within deck reinforcement layers"
    },
    {
      "name": "reinforcement bar",
      "tag": "400C",
      "shape": "bar, longitudinal",
      "material": "reinforcement steel",
      "count": 2,
      "note": "longitudinal bar labeled '400C', shown near '2'-0\" MIN. LAP' callout"
    },
    {
      "name": "fence post",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "only spacing dimensions shown, posts themselves not drawn; labeled 'FENCE POST SPACING'"
    }
  ],
  "measurements": [
    {
      "label": "overall deck width",
      "value": "82'-0\"",
      "unit": "",
      "appliesTo": "deck (both spans/decks)"
    },
    {
      "label": "panel spacing",
      "value": "16'-4 1/2\"",
      "unit": "",
      "appliesTo": "deck transverse spacing, repeated 4 times"
    },
    {
      "label": "end panel spacing",
      "value": "16'-6\"",
      "unit": "",
      "appliesTo": "deck transverse spacing, end panel"
    },
    {
      "label": "sub-spacing",
      "value": "9'-6\"",
      "unit": "",
      "appliesTo": "spacing between 502D/502E bars, top row"
    },
    {
      "label": "sub-spacing (alt row)",
      "value": "9'-10 1/2\"",
      "unit": "",
      "appliesTo": "spacing between 502D/502E bars, second row"
    },
    {
      "label": "end offset",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "edge offset to first bar/fence post, top and bottom rows"
    },
    {
      "label": "end offset (alt)",
      "value": "2'-0\"",
      "unit": "",
      "appliesTo": "edge offset to first bar, middle rows"
    },
    {
      "label": "end offset (alt)",
      "value": "1'-0\"",
      "unit": "",
      "appliesTo": "edge offset near fence post spacing, middle rows"
    },
    {
      "label": "fillet thickness",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "fillet, typ."
    },
    {
      "label": "edgebeam width",
      "value": "1'-0\"",
      "unit": "",
      "appliesTo": "edgebeam, typ."
    },
    {
      "label": "diaphragm thickness",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "concrete diaphragm, typ."
    },
    {
      "label": "minimum lap",
      "value": "2'-0\"",
      "unit": "",
      "appliesTo": "400B/400C bar lap, marked with ** symbol"
    },
    {
      "label": "skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "deck end skew, typ."
    },
    {
      "label": "bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "construction centerline SR 21"
    },
    {
      "label": "gutter to gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "westbound and eastbound deck"
    },
    {
      "label": "out to out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "westbound and eastbound deck"
    },
    {
      "label": "curb offset",
      "value": "1'-9 1/2\"",
      "unit": "",
      "appliesTo": "gutter to out-to-out edge offset"
    },
    {
      "label": "lap bar spacing at ends",
      "value": "5'-0\"",
      "unit": "",
      "appliesTo": "** marked lap bars near deck ends"
    },
    {
      "label": "median width",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "distance between PGL Westbound and PGL Eastbound centerlines"
    },
    {
      "label": "span label",
      "value": "SPAN 2",
      "unit": "",
      "appliesTo": "overall deck plan"
    }
  ],
  "notes": [],
  "labels": [
    "SPAN 2",
    "CONSTRUCTION ℄ SR 21",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "FENCE POST SPACING",
    "8\" FILLET, TYP.",
    "1'-0\" EDGEBEAM, TYP.",
    "10\" CONCRETE DIAPHRAGM, TYP.",
    "2'-0\" MIN. LAP",
    "℄ BEAM 1",
    "℄ BEAM 2",
    "℄ BEAM 3",
    "℄ BEAM 4",
    "℄ BEAM 5",
    "℄ BEAM 6",
    "℄ BEAM 7",
    "℄ BEAM 8",
    "℄ BEAM 9",
    "℄ BEAM 10",
    "℄ BEAM 11",
    "℄ BEAM 12"
  ],
  "description": "This crop is a plan view of Span 2 of a twin-roadway bridge deck, showing two parallel skewed deck panels (westbound and eastbound) each supported on six beams (Beams 1-6 and 7-12), with dimensioned transverse spacing, edge beams, fillets, concrete diaphragms, and top-slab reinforcement bars (502D, 502E, 400B, 400C) including a minimum lap callout. Overall deck geometry (82'-0\" width, 81°20'05.0\" skew, gutter-to-gutter and out-to-out widths) and the SR 21 construction centerline bearing are also annotated."
}

p05_r01Plan

  • concrete diaphragmtransverse stripconcretelabeled '10" CONCRETE DIAPHRAGM, TYP.' at multiple locations between beams

82'-0" overall deck width16'-4 1/2" panel spacing16'-6" end panel spacing9'-6" sub-spacing9'-10 1/2" sub-spacing (alt row)3'-0" end offset2'-0" end offset (alt)1'-0" end offset (alt)+12 more

Page 6

crop

p06_r01 title block

page 6 · gdot_plan_649084f395824aaebf1f5ed48132696f_p06_r01_title_block
Original
p06_r01 title block
{
  "view": "Plan",
  "objects": [
    {
      "name": "Beam",
      "tag": "BEAM 1-12",
      "shape": "linear, longitudinal",
      "material": "precast concrete",
      "count": 12,
      "note": "Six beams shown per each of two deck halves (westbound and eastbound), individually labeled BEAM 1 through BEAM 12"
    },
    {
      "name": "Concrete diaphragm",
      "tag": "",
      "shape": "rectangular, transverse",
      "material": "concrete",
      "count": 6,
      "note": "Labeled '10\" CONCRETE DIAPHRAGM, TYP.'; shown between beams at intermediate locations, three per deck half"
    },
    {
      "name": "Edge beam",
      "tag": "",
      "shape": "linear",
      "material": "concrete",
      "count": 2,
      "note": "Labeled '1'-0\" EDGEBEAM, TYP.', one along each deck half"
    },
    {
      "name": "Fillet",
      "tag": "",
      "shape": "linear, tapered edge detail",
      "material": "concrete",
      "count": 2,
      "note": "Labeled '8\" FILLET, TYP.'"
    },
    {
      "name": "Endwall",
      "tag": "",
      "shape": "linear, angled",
      "material": "concrete",
      "count": 4,
      "note": "Two sizes noted: '3'-0\" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.' and '1'-6\" ENDWALL', two each (one per deck end)"
    },
    {
      "name": "Paving rest",
      "tag": "",
      "shape": "linear",
      "material": "concrete",
      "count": 2,
      "note": "Labeled '12\" PAVING REST' at bent ends"
    },
    {
      "name": "Bent",
      "tag": "BENT 4",
      "shape": "",
      "material": "concrete",
      "count": 2,
      "note": "Labeled 'B.F.P.R. BENT 4' at both ends of the span (top and bottom edges of deck plan)"
    },
    {
      "name": "Reinforcement bar group",
      "tag": "12-502A",
      "shape": "",
      "material": "reinforcing steel",
      "count": 6,
      "note": "Appears at top and bottom edges of deck (fence post/parapet reinforcement), 3 marks per edge x2 edges"
    },
    {
      "name": "Reinforcement bar group",
      "tag": "12-502B",
      "shape": "",
      "material": "reinforcing steel",
      "count": 3,
      "note": "Appears along eastbound deck edge near construction centerline"
    },
    {
      "name": "Reinforcement bar group",
      "tag": "12-502C",
      "shape": "",
      "material": "reinforcing steel",
      "count": 3,
      "note": "Appears along westbound deck edge near construction centerline"
    },
    {
      "name": "Reinforcement bar mark",
      "tag": "400A",
      "shape": "",
      "material": "reinforcing steel",
      "count": 2,
      "note": "Labeled once per deck half, likely deck slab main reinforcement"
    },
    {
      "name": "Fence post spacing markers",
      "tag": "",
      "shape": "point markers",
      "material": "",
      "count": null,
      "note": "Rows of dimensioned spacing along both outer edges and inner edges of both deck halves; some marked with * and ** symbols"
    },
    {
      "name": "End post",
      "tag": "END POST",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "Located at inner ends of each deck half near construction centerline of SR 21"
    }
  ],
  "measurements": [
    {
      "label": "Overall deck width, top deck",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "westbound deck outer bay"
    },
    {
      "label": "Beam bay spacing (3 bays)",
      "value": "18'-4\"",
      "unit": "",
      "appliesTo": "westbound deck, repeated 3 times"
    },
    {
      "label": "Fence post spacing sequence",
      "value": "6'-6\", 9'-6\", 9'-6\", 9'-6\", 9'-6\", 9'-6\"",
      "unit": "",
      "appliesTo": "westbound deck outer edge"
    },
    {
      "label": "End dimension",
      "value": "1'-0\"",
      "unit": "",
      "appliesTo": "westbound deck outer edge end"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "deck skew, typ."
    },
    {
      "label": "Diaphragm thickness",
      "value": "10\"",
      "unit": "",
      "appliesTo": "concrete diaphragm"
    },
    {
      "label": "Fillet dimension",
      "value": "8\"",
      "unit": "",
      "appliesTo": "fillet, typ."
    },
    {
      "label": "Edgebeam width",
      "value": "1'-0\"",
      "unit": "",
      "appliesTo": "edgebeam, typ."
    },
    {
      "label": "Endwall dimension (exterior)",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "endwall outside exterior beam, typ."
    },
    {
      "label": "Endwall dimension (other)",
      "value": "1'-6\"",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "Paving rest width",
      "value": "12\"",
      "unit": "",
      "appliesTo": "paving rest"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "westbound/eastbound deck section"
    },
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "westbound/eastbound deck section"
    },
    {
      "label": "Offset at edge",
      "value": "1'-9 1/2\"",
      "unit": "",
      "appliesTo": "deck edge offset from gutter line, top and bottom"
    },
    {
      "label": "Beam spacing bay (5'-0\" marks)",
      "value": "5'-0\"",
      "unit": "",
      "appliesTo": "Beam 1/Beam 2 area and Beam 11/Beam 12 area"
    },
    {
      "label": "Fence post spacing sequence (lower rows)",
      "value": "6'-2 3/8\", 9'-6\", 9'-6\", 8'-0\", 8'-9\", 8'-9\"",
      "unit": "",
      "appliesTo": "inner edge near bent 4, westbound"
    },
    {
      "label": "End post dimension",
      "value": "4'-6\"",
      "unit": "",
      "appliesTo": "end post, westbound"
    },
    {
      "label": "Sub-span dimension",
      "value": "17'-2 3/4\", 17'-2 13/16\", 17'-2 13/16\"",
      "unit": "",
      "appliesTo": "inner deck edge dimensions"
    },
    {
      "label": "Total inner edge length",
      "value": "51'-8 3/8\"",
      "unit": "",
      "appliesTo": "westbound inner deck edge total"
    },
    {
      "label": "Total deck length (construction centerline area)",
      "value": "52'-2 13/16\"",
      "unit": "",
      "appliesTo": "deck length along construction centerline SR 21"
    },
    {
      "label": "Sub-span dimension",
      "value": "17'-5 1/4\", 17'-5 1/4\", 17'-4 5/16\"",
      "unit": "",
      "appliesTo": "eastbound inner deck edge"
    },
    {
      "label": "Fence post spacing sequence (eastbound inner)",
      "value": "6'-8 13/16\", 9'-6\", 9'-6\", 8'-0\", 8'-9\", 8'-9\"",
      "unit": "",
      "appliesTo": "eastbound deck inner edge"
    },
    {
      "label": "End post dimension",
      "value": "4'-3\"",
      "unit": "",
      "appliesTo": "end post, eastbound"
    },
    {
      "label": "Total width, bottom deck",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "eastbound deck outer bay"
    },
    {
      "label": "Beam bay spacing (3 bays), bottom deck",
      "value": "18'-4\"",
      "unit": "",
      "appliesTo": "eastbound deck, repeated 3 times"
    },
    {
      "label": "Fence post spacing sequence, bottom",
      "value": "6'-6\", 9'-6\", 9'-6\", 9'-6\", 9'-6\", 9'-6\"",
      "unit": "",
      "appliesTo": "eastbound deck outer edge"
    },
    {
      "label": "Skew/bearing angle line",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "reference bearing line between decks"
    },
    {
      "label": "Gutter to gutter width (repeat)",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "partial dimension near end post areas"
    }
  ],
  "notes": [
    "FENCE POST SPACING",
    "1'-0\" EDGEBEAM, TYP.",
    "8\" FILLET, TYP.",
    "81°-20'-05.0\", TYP.",
    "10\" CONCRETE DIAPHRAGM, TYP.",
    "3'-0\" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.",
    "1'-6\" ENDWALL",
    "12\" PAVING REST",
    "B.F.P.R. BENT 4",
    "CONSTRUCTION ℄ SR 21",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "N 83°-43'-21.7\" E"
  ],
  "labels": [
    "SPAN 3",
    "DECK PLAN",
    "℄ BEAM 1",
    "℄ BEAM 2",
    "℄ BEAM 3",
    "℄ BEAM 4",
    "℄ BEAM 5",
    "℄ BEAM 6",
    "℄ BEAM 7",
    "℄ BEAM 8",
    "℄ BEAM 9",
    "℄ BEAM 10",
    "℄ BEAM 11",
    "℄ BEAM 12",
    "12-502A",
    "12-502B",
    "12-502C",
    "400A",
    "END POST"
  ],
  "description": "This crop is a deck plan view for Span 3 of a bridge, showing two parallel roadway decks (westbound and eastbound), each carrying six precast beams (Beams 1-6 and 7-12 respectively) supported at Bent 4. The drawing details fence post spacing, edge beams, fillets, concrete diaphragms, endwalls, and paving rests, along with numerous linear dimensions, skew angles, and gutter/out-to-out width callouts for both deck halves. Reinforcement bar marks (12-502A/B/C, 400A) are called out at deck edges and diaphragm locations, indicating this sheet documents deck slab layout and edge/fence detailing for take-off of concrete and reinforcement quantities."
}

p06_r01 title blockPlan

  • Concrete diaphragm×6rectangular, transverseconcreteLabeled '10" CONCRETE DIAPHRAGM, TYP.'; shown between beams at intermediate locations, three per deck half

55'-0" Overall deck width, top deck18'-4" Beam bay spacing (3 bays)6'-6", 9'-6", 9'-6", 9'-6", 9'-6", 9'-6" Fence post spacing sequence1'-0" End dimension81°-20'-05.0" Skew angle10" Diaphragm thickness8" Fillet dimension1'-0" Edgebeam width+20 more

crop

p06_r01

page 6 · other_p06_r01
Original
p06_r01
{
  "view": "Plan",
  "objects": [
    {
      "name": "Beam",
      "tag": "BEAM 1-12",
      "shape": "longitudinal, parallel",
      "material": "precast concrete (implied)",
      "count": 12,
      "note": "Centerlines of 12 beams shown (BEAM 1 through BEAM 12), 6 per roadway (westbound and eastbound)."
    },
    {
      "name": "Fence post anchorage/rebar",
      "tag": "12-502A",
      "shape": "",
      "material": "reinforcement bar (implied)",
      "count": 6,
      "note": "Marks at top and bottom edges of deck plan, at fence post spacing locations."
    },
    {
      "name": "Fence post anchorage/rebar",
      "tag": "12-502B",
      "shape": "",
      "material": "reinforcement bar (implied)",
      "count": 3,
      "note": "Marks along eastbound roadway upper edge."
    },
    {
      "name": "Fence post anchorage/rebar",
      "tag": "12-502C",
      "shape": "",
      "material": "reinforcement bar (implied)",
      "count": 3,
      "note": "Marks along westbound roadway lower edge."
    },
    {
      "name": "Edgebeam",
      "tag": "",
      "shape": "linear, 1'-0\" wide",
      "material": "reinforced concrete (implied)",
      "count": 2,
      "note": "Typical edgebeam along outer edge of each roadway deck."
    },
    {
      "name": "Concrete diaphragm",
      "tag": "400A",
      "shape": "transverse, 10\" thick",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Typical diaphragm between beams, shown at midspan of each roadway; tag 400A appears once per roadway."
    },
    {
      "name": "Endwall",
      "tag": "",
      "shape": "linear, 1'-6\" and 3'-0\" widths",
      "material": "concrete (implied)",
      "count": 4,
      "note": "1'-6\" endwall and 3'-0\" endwall outside exterior beam, at both ends of each roadway."
    },
    {
      "name": "Fillet",
      "tag": "",
      "shape": "linear, 8\" typical",
      "material": "concrete (implied)",
      "count": 2,
      "note": "8\" fillet typical, shown along beam lines."
    },
    {
      "name": "Paving rest",
      "tag": "",
      "shape": "linear, 12\" wide",
      "material": "concrete (implied)",
      "count": 2,
      "note": "12\" paving rest at end of each roadway deck."
    },
    {
      "name": "Bent",
      "tag": "BENT 4",
      "shape": "",
      "material": "concrete (implied)",
      "count": 1,
      "note": "Referenced as 'B.F.P.R. BENT 4' (likely 'Back Face of Pier/Bent Rest') at the far end of the span for both roadways."
    },
    {
      "name": "Fence post spacing markers",
      "tag": "*",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Asterisk symbols denote fence post spacing locations, referenced but not individually described."
    },
    {
      "name": "End post",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "Labeled 'END POST' at the terminal fence post location on each roadway."
    }
  ],
  "measurements": [
    {
      "label": "Overall deck width",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound roadway (top)"
    },
    {
      "label": "Segment width",
      "value": "18'-4\"",
      "unit": "ft-in",
      "appliesTo": "Westbound roadway (3 segments)"
    },
    {
      "label": "Fence post spacing",
      "value": "6'-6\"",
      "unit": "ft-in",
      "appliesTo": "Westbound roadway, first spacing"
    },
    {
      "label": "Fence post spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "Westbound roadway (repeated 5 times)"
    },
    {
      "label": "Fence post spacing (end)",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound roadway, end spacing"
    },
    {
      "label": "Post bracket spacing",
      "value": "5'-0\"",
      "unit": "ft-in",
      "appliesTo": "Near Beam 1, both sides"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "degrees-min-sec",
      "appliesTo": "Beam skew, typical"
    },
    {
      "label": "Diaphragm thickness",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "Concrete diaphragm, typical"
    },
    {
      "label": "Edgebeam width",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Edgebeam, typical"
    },
    {
      "label": "Fillet size",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "Fillet, typical"
    },
    {
      "label": "Endwall width",
      "value": "3'-0\"",
      "unit": "ft-in",
      "appliesTo": "Endwall outside exterior beam, typical"
    },
    {
      "label": "Endwall width",
      "value": "1'-6\"",
      "unit": "ft-in",
      "appliesTo": "Endwall"
    },
    {
      "label": "Paving rest width",
      "value": "12\"",
      "unit": "in",
      "appliesTo": "Paving rest"
    },
    {
      "label": "Gutter to gutter",
      "value": "40'-0\"",
      "unit": "ft-in",
      "appliesTo": "Roadway width, both roadways"
    },
    {
      "label": "Out to out",
      "value": "43'-7\"",
      "unit": "ft-in",
      "appliesTo": "Deck width, both roadways"
    },
    {
      "label": "Edge offset",
      "value": "1'-9 1/2\"",
      "unit": "ft-in",
      "appliesTo": "Edge distance, both roadways (multiple locations)"
    },
    {
      "label": "Roadway offset",
      "value": "22'-0\"",
      "unit": "ft-in",
      "appliesTo": "Half-width dimension, both roadways"
    },
    {
      "label": "Fence post spacing (lower edge)",
      "value": "6'-2 3/8\"",
      "unit": "ft-in",
      "appliesTo": "Westbound roadway lower edge, first spacing"
    },
    {
      "label": "Fence post spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge (x2)"
    },
    {
      "label": "Fence post spacing",
      "value": "8'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge"
    },
    {
      "label": "Fence post spacing",
      "value": "8'-9\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge (x2)"
    },
    {
      "label": "End spacing",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge end"
    },
    {
      "label": "End post width",
      "value": "4'-6\"",
      "unit": "ft-in",
      "appliesTo": "End post, westbound lower edge"
    },
    {
      "label": "Segment length",
      "value": "17'-2 3/4\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge segment"
    },
    {
      "label": "Segment length",
      "value": "17'-2 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge segment (x2)"
    },
    {
      "label": "Total length",
      "value": "51'-8 3/8\"",
      "unit": "ft-in",
      "appliesTo": "Westbound lower edge total"
    },
    {
      "label": "Bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "bearing",
      "appliesTo": "Construction centerline SR 21"
    },
    {
      "label": "Total length",
      "value": "52'-2 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound roadway upper edge total"
    },
    {
      "label": "Segment length",
      "value": "17'-5 1/4\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound upper edge segment (x2)"
    },
    {
      "label": "Segment length",
      "value": "17'-4 5/16\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound upper edge segment"
    },
    {
      "label": "Fence post spacing",
      "value": "6'-8 13/16\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound roadway upper edge, first spacing"
    },
    {
      "label": "Fence post spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound upper edge (x2)"
    },
    {
      "label": "Fence post spacing",
      "value": "8'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound upper edge"
    },
    {
      "label": "Fence post spacing",
      "value": "8'-9\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound upper edge (x2)"
    },
    {
      "label": "End spacing",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound upper edge end"
    },
    {
      "label": "End post width",
      "value": "4'-3\"",
      "unit": "ft-in",
      "appliesTo": "End post, eastbound upper edge"
    },
    {
      "label": "Fence post spacing",
      "value": "6'-6\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound roadway lower edge, first spacing"
    },
    {
      "label": "Fence post spacing",
      "value": "9'-6\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound lower edge (repeated 5 times)"
    },
    {
      "label": "End spacing",
      "value": "1'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound lower edge end"
    },
    {
      "label": "Segment width",
      "value": "18'-4\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound roadway (3 segments)"
    },
    {
      "label": "Overall deck width",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Eastbound roadway (bottom)"
    }
  ],
  "notes": [
    "FENCE POST SPACING",
    "8\" FILLET, TYP.",
    "1'-0\" EDGEBEAM, TYP.",
    "10\" CONCRETE DIAPHRAGM, TYP.",
    "81°-20'-05.0\", TYP.",
    "3'-0\" ENDWALL OUTSIDE EXTERIOR BEAM, TYP.",
    "1'-6\" ENDWALL",
    "12\" PAVING REST",
    "END POST"
  ],
  "labels": [
    "DECK PLAN",
    "SPAN 3",
    "CONSTRUCTION ℄ SR 21",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "GUTTER TO GUTTER",
    "OUT TO OUT",
    "B.F.P.R. BENT 4"
  ],
  "description": "This crop is a plan view titled 'DECK PLAN' for 'SPAN 3' of a bridge, showing the deck geometry for two parallel roadways (westbound and eastbound) each supported on six beams (Beams 1-6 and 7-12). It details fence post spacing, edgebeam, concrete diaphragm, fillet, endwall, and paving rest dimensions along the skewed deck edges, along with overall width, gutter-to-gutter, and out-to-out dimensions, plus a construction centerline bearing and skew angle for SR 21."
}

p06_r01Plan

  • Concrete diaphragm400A×2transverse, 10" thickreinforced concreteTypical diaphragm between beams, shown at midspan of each roadway; tag 400A appears once per roadway.

55'-0" ft-in Overall deck width18'-4" ft-in Segment width6'-6" ft-in Fence post spacing9'-6" ft-in Fence post spacing1'-0" ft-in Fence post spacing (end)5'-0" ft-in Post bracket spacing81°-20'-05.0" degrees-min-sec Skew angle10" in Diaphragm thickness+33 more

Page 7

crop

p07_r01 section thru slab

page 7 · gdot_plan_649084f395824aaebf1f5ed48132696f_p07_r01_section_thru_slab
Original
p07_r01 section thru slab
{
  "view": "Cross Section",
  "objects": [
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "flat with 2% cross slope",
      "material": "reinforced concrete",
      "count": 1,
      "note": "7 3/4\" thick between beams, 8\" in overhangs; top slab of bridge cross section"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 1",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "exterior beam, left side"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 2",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 3",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 4",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 5",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 6",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "exterior beam, right side"
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "rectangular, cast between beams",
      "material": "reinforced concrete",
      "count": 5,
      "note": "shown in lower 'SECTION THRU DIAPHRAGM' view, between each pair of adjacent beams"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400A",
      "shape": "bar (deck top mat)",
      "material": "reinforcement steel",
      "count": null,
      "note": "spaced as shown, groups of 6, 14, 30 at various locations along slab"
    },
    {
      "name": "Reinforcement bar",
      "tag": "500A",
      "shape": "bar (deck bottom mat)",
      "material": "reinforcement steel",
      "count": null,
      "note": "at 6 1/2\" spacing"
    },
    {
      "name": "Reinforcement bar",
      "tag": "501",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "placed under every 500A bar"
    },
    {
      "name": "Reinforcement bar",
      "tag": "502",
      "shape": "bar",
      "material": "reinforcement steel",
      "count": null,
      "note": "placed at every 500A bar"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403A",
      "shape": "bar (diaphragm)",
      "material": "reinforcement steel",
      "count": 7,
      "note": "at equal spaces, in diaphragm section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402A",
      "shape": "bar (diaphragm)",
      "material": "reinforcement steel",
      "count": 4,
      "note": "diaphragm reinforcement"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507A",
      "shape": "bar (diaphragm)",
      "material": "reinforcement steel",
      "count": 2,
      "note": "diaphragm reinforcement, shown twice at two locations"
    },
    {
      "name": "Plain bar (tie rod)",
      "tag": "",
      "shape": "circular, 1\" diameter",
      "material": "plain steel",
      "count": null,
      "note": "through diaphragms"
    },
    {
      "name": "Drip bead",
      "tag": "",
      "shape": "triangular",
      "material": "unspecified (likely sealant/concrete)",
      "count": 1,
      "note": "3/4\" triangular drip bead, full length of bridge, typical at fascia edge"
    },
    {
      "name": "Construction joint",
      "tag": "",
      "shape": "linear, parallel to deck",
      "material": "",
      "count": 1,
      "note": "required construction joint parallel with deck, typ."
    },
    {
      "name": "Fence (not shown)",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 0,
      "note": "noted as not shown but location indicated typ. at both edges"
    }
  ],
  "measurements": [
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "deck cross section"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "deck cross section"
    },
    {
      "label": "Width dimension",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "deck cross section"
    },
    {
      "label": "Right side offset",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "deck cross section, from centerline"
    },
    {
      "label": "Right side offset",
      "value": "14'-2 1/2\"",
      "unit": "",
      "appliesTo": "deck cross section, from edge"
    },
    {
      "label": "Right shoulder/lane width",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "deck cross section, right of PGL"
    },
    {
      "label": "Overhang width",
      "value": "1'-8\"",
      "unit": "",
      "appliesTo": "left and right overhangs"
    },
    {
      "label": "Edge offset",
      "value": "1 1/2\"",
      "unit": "",
      "appliesTo": "outer edge dimension, both sides"
    },
    {
      "label": "Edge thickness",
      "value": "8\"",
      "unit": "",
      "appliesTo": "overhang slab thickness, both sides"
    },
    {
      "label": "Slab thickness between beams",
      "value": "7 3/4\"",
      "unit": "",
      "appliesTo": "slab"
    },
    {
      "label": "Cross slope",
      "value": "2%",
      "unit": "%",
      "appliesTo": "deck slab"
    },
    {
      "label": "Clear cover top",
      "value": "2 1/4\"",
      "unit": "",
      "appliesTo": "deck reinforcement"
    },
    {
      "label": "Clear cover bottom",
      "value": "1\"",
      "unit": "",
      "appliesTo": "deck reinforcement"
    },
    {
      "label": "Dimension D interior beams",
      "value": "8 3/4\"",
      "unit": "",
      "appliesTo": "interior beams"
    },
    {
      "label": "Dimension D exterior beams",
      "value": "9 1/8\"",
      "unit": "",
      "appliesTo": "exterior beams"
    },
    {
      "label": "Rebar spacing 500A",
      "value": "6 1/2\"",
      "unit": "",
      "appliesTo": "500A bars"
    },
    {
      "label": "Rebar group",
      "value": "30-400A",
      "unit": "",
      "appliesTo": "400A bars, spaced as shown"
    },
    {
      "label": "Rebar group",
      "value": "6-400A",
      "unit": "",
      "appliesTo": "400A bars at eq. sps., both sides"
    },
    {
      "label": "Rebar group",
      "value": "14-400A",
      "unit": "",
      "appliesTo": "400A bars at equal spaces, typ., near center"
    },
    {
      "label": "Bearing offset dimension",
      "value": "4 3/8\"",
      "unit": "",
      "appliesTo": "both edges of section"
    },
    {
      "label": "Offset dimension",
      "value": "3\"",
      "unit": "",
      "appliesTo": "multiple locations along section, typ."
    },
    {
      "label": "Minimum offset",
      "value": "3'-0\" MIN.",
      "unit": "",
      "appliesTo": "typ. dimension near right side"
    },
    {
      "label": "Beam spacing",
      "value": "3'-0 1/2\"",
      "unit": "",
      "appliesTo": "Beam 1 and Beam 6 to edge"
    },
    {
      "label": "Beam spacing",
      "value": "7'-6\"",
      "unit": "",
      "appliesTo": "spacing between Beam 1-2, 2-3, 3-4, 4-5, 5-6"
    },
    {
      "label": "Rebar group diaphragm",
      "value": "7-403A",
      "unit": "",
      "appliesTo": "403A bars at equal spaces, diaphragm section"
    },
    {
      "label": "Diaphragm edge offset",
      "value": "5\"",
      "unit": "",
      "appliesTo": "diaphragm section, both sides"
    },
    {
      "label": "Plain bar diameter",
      "value": "1\"",
      "unit": "",
      "appliesTo": "plain tie bar, diaphragm"
    }
  ],
  "notes": [
    "DIMENSION \"D\" IS MEASURED FROM TOP OF SLAB TO TOP OF BEAMS AT CENTERLINE BEARING. VARY \"D\" BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTION, AND VERTICAL CURVE.",
    "MAINTAIN A CONSTANT SLAB THICKNESS OF 7 3/4\" BETWEEN BEAMS AND 8\" IN THE OVERHANGS.",
    "\"D\" = 8 3/4\" INTERIOR BEAMS",
    "\"D\" = 9 1/8\" EXTERIOR BEAMS",
    "FENCE NOT SHOWN, TYP.",
    "502 AT EVERY 500A, TYP.",
    "30-400A SPACED AS SHOWN",
    "500A AT 6 1/2\"",
    "501 UNDER EVERY 500A",
    "REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.",
    "3/4\" TRIANGULAR DRIP BEAD FULL LENGTH OF BRIDGE, TYP.",
    "6-400A AT EQ. SPS.",
    "14-400A AT EQUAL SPACES, TYP.",
    "7-403A AT EQUAL SPACES",
    "1\" DIAMETER PLAIN BAR"
  ],
  "labels": [
    "SR 21 WB = PGL",
    "SECTION THRU SLAB",
    "SECTION THRU DIAPHRAGM",
    "C BEAM 1",
    "C BEAM 2",
    "C BEAM 3",
    "C BEAM 4",
    "C BEAM 5",
    "C BEAM 6"
  ],
  "description": "This crop shows two cross sections of a precast girder bridge superstructure: an upper 'SECTION THRU SLAB' spanning six beams (Beam 1 through Beam 6) with full deck slab dimensions, cross-slope, reinforcement (400A, 500A, 501, 502 bars), overhang and edge details, and a lower 'SECTION THRU DIAPHRAGM' showing diaphragm reinforcement (403A, 402A, 507A bars) and a plain tie bar between the same beam line. Notes at the top explain the variable dimension 'D' used to set beam elevations relative to the slab for dead load deflection and vertical curve compensation. This documents deck slab and diaphragm concrete/reinforcement quantities for a multi-beam concrete bridge deck."
}

p07_r01 section thru slabCross Section

  • Diaphragm×5rectangular, cast between beamsreinforced concreteshown in lower 'SECTION THRU DIAPHRAGM' view, between each pair of adjacent beams

43'-7" Out to out width40'-0" Gutter to gutter width34'-0" Width dimension22'-0" Right side offset14'-2 1/2" Right side offset6'-0" Right shoulder/lane width1'-8" Overhang width1 1/2" Edge offset+19 more

crop

p07_r04 1 cl typ

page 7 · gdot_plan_649084f395824aaebf1f5ed48132696f_p07_r04_1_cl_typ
Original
p07_r04 1 cl typ
{
  "view": "Detail",
  "objects": [
    {
      "name": "Concrete diaphragm",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Shown in cross section between beams, labeled 10\" CONC. DIAPH."
    },
    {
      "name": "PSC beam",
      "tag": "",
      "shape": "rectangular (partial, horizontal lines representing beam depth)",
      "material": "precast concrete",
      "count": null,
      "note": "Only top portion of beam shown, labeled TOP OF BEAM"
    },
    {
      "name": "Reinforcement bar (stirrup/tie)",
      "tag": "507A",
      "shape": "circular (bar ends shown as dots, diagonal crossing pattern)",
      "material": "steel reinforcement",
      "count": 4,
      "note": "2-507A at top, 2-507A at bottom of diaphragm reinforcement cage"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402A",
      "shape": "circular (bar ends shown as dots)",
      "material": "steel reinforcement",
      "count": 4,
      "note": "4-402A, diagonal crossing bars within diaphragm"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403A",
      "shape": "",
      "material": "steel reinforcement",
      "count": null,
      "note": "Labeled with leader pointing into diaphragm reinforcement cage, count not distinguishable from 402A/507A dots"
    },
    {
      "name": "Plain bar",
      "tag": "",
      "shape": "circular",
      "material": "steel (plain, unspecified grade)",
      "count": 2,
      "note": "1\" DIA. PLAIN BAR, shown as solid dots within cage"
    }
  ],
  "measurements": [
    {
      "label": "Diaphragm width",
      "value": "10",
      "unit": "in",
      "appliesTo": "Concrete diaphragm"
    },
    {
      "label": "Top clearance",
      "value": "2",
      "unit": "in",
      "appliesTo": "Top of beam to reinforcement"
    },
    {
      "label": "Overall height dimension",
      "value": "2'-4\"",
      "unit": "ft-in",
      "appliesTo": "Beam/diaphragm section height"
    },
    {
      "label": "Clear cover, typical",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "Reinforcement bars (CL. TYP.)"
    },
    {
      "label": "Plain bar diameter",
      "value": "1",
      "unit": "in",
      "appliesTo": "Plain bar"
    }
  ],
  "notes": [
    "10\" CONC. DIAPH.",
    "TOP OF BEAM",
    "1 1/2\" CL. TYP.",
    "1\" DIA. PLAIN BAR",
    "2-507A",
    "403A",
    "4-402A",
    "2-507A"
  ],
  "labels": [
    "10\" CONC. DIAPH.",
    "TOP OF BEAM",
    "1 1/2\" CL. TYP.",
    "403A",
    "1\" DIA. PLAIN BAR",
    "2-507A",
    "4-402A"
  ],
  "description": "This crop is a detail section showing the reinforcement layout within a concrete diaphragm between precast beams, viewed in cross section. It calls out a 10-inch wide concrete diaphragm with a reinforcement cage consisting of 507A, 402A, and 403A bars along with a 1-inch diameter plain bar, with clearances and overall depth dimensioned. The detail focuses solely on the diaphragm reinforcement region near the top of the beam, with beam ends broken off left and right indicating a partial/typical detail rather than a full structure."
}

p07_r04 1 cl typDetail

  • Concrete diaphragm×1rectangularreinforced concreteShown in cross section between beams, labeled 10" CONC. DIAPH.

10 in Diaphragm width2 in Top clearance2'-4" ft-in Overall height dimension1 1/2 in Clear cover, typical1 in Plain bar diameter

crop

p07_r01

page 7 · other_p07_r01
Original
p07_r01
{
  "view": "Cross Section",
  "objects": [
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "rectangular/tapered (crowned)",
      "material": "reinforced concrete",
      "count": 1,
      "note": "7.75\" thick between beams, 8\" in overhangs, 2% cross slope"
    },
    {
      "name": "PSC Beam",
      "tag": "BEAM 1",
      "shape": "bulb-tee/I-section",
      "material": "precast concrete",
      "count": 1,
      "note": "exterior beam"
    },
    {
      "name": "PSC Beam",
      "tag": "BEAM 2",
      "shape": "bulb-tee/I-section",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC Beam",
      "tag": "BEAM 3",
      "shape": "bulb-tee/I-section",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC Beam",
      "tag": "BEAM 4",
      "shape": "bulb-tee/I-section",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC Beam",
      "tag": "BEAM 5",
      "shape": "bulb-tee/I-section",
      "material": "precast concrete",
      "count": 1,
      "note": "interior beam"
    },
    {
      "name": "PSC Beam",
      "tag": "BEAM 6",
      "shape": "bulb-tee/I-section",
      "material": "precast concrete",
      "count": 1,
      "note": "exterior beam"
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 5,
      "note": "intermediate diaphragms between beams, shown in second section view"
    },
    {
      "name": "Edge parapet/barrier upstand",
      "tag": "",
      "shape": "tapered",
      "material": "reinforced concrete",
      "count": 2,
      "note": "fence-mounting curb at each edge, fence itself not shown"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400A",
      "shape": "",
      "material": "steel",
      "count": null,
      "note": "transverse slab bars, spaced as noted (30-400A shown, also 6-400A, 14-400A groupings)"
    },
    {
      "name": "Reinforcement bar",
      "tag": "500A",
      "shape": "",
      "material": "steel",
      "count": null,
      "note": "longitudinal top bar at 6.5\" spacing"
    },
    {
      "name": "Reinforcement bar",
      "tag": "501",
      "shape": "",
      "material": "steel",
      "count": null,
      "note": "placed under every 500A"
    },
    {
      "name": "Reinforcement bar",
      "tag": "502",
      "shape": "",
      "material": "steel",
      "count": null,
      "note": "placed at every 500A"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403A",
      "shape": "",
      "material": "steel",
      "count": 7,
      "note": "diaphragm bars, at equal spaces"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402A",
      "shape": "",
      "material": "steel",
      "count": 4,
      "note": "diaphragm bars"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507A",
      "shape": "",
      "material": "steel",
      "count": 2,
      "note": "diaphragm top bars"
    },
    {
      "name": "Reinforcement bar",
      "tag": "",
      "shape": "circular, plain",
      "material": "steel",
      "count": null,
      "note": "1\" diameter plain bar, likely a diaphragm through-rod"
    },
    {
      "name": "Construction joint",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "required construction joint parallel with deck"
    },
    {
      "name": "Drip bead",
      "tag": "",
      "shape": "triangular",
      "material": "",
      "count": 2,
      "note": "3/4\" triangular drip bead, full length of bridge, typical at each fascia edge"
    }
  ],
  "measurements": [
    {
      "label": "Slab thickness between beams",
      "value": "7 3/4",
      "unit": "in",
      "appliesTo": "deck slab"
    },
    {
      "label": "Slab thickness in overhangs",
      "value": "8",
      "unit": "in",
      "appliesTo": "deck slab overhang"
    },
    {
      "label": "Dimension D, interior beams",
      "value": "8 3/4",
      "unit": "in",
      "appliesTo": "interior beams"
    },
    {
      "label": "Dimension D, exterior beams",
      "value": "9 1/8",
      "unit": "in",
      "appliesTo": "exterior beams"
    },
    {
      "label": "Overall width",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "half-width dimension shown at top right"
    },
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "deck"
    },
    {
      "label": "Right side width",
      "value": "14'-2 1/2\"",
      "unit": "",
      "appliesTo": "deck"
    },
    {
      "label": "Gutter to gutter",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "deck"
    },
    {
      "label": "Width dimension",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "deck (between beam 1 and beam 6 approx)"
    },
    {
      "label": "Right lane dimension",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "deck"
    },
    {
      "label": "Overhang edge width",
      "value": "1'-8\"",
      "unit": "",
      "appliesTo": "edge overhang, both sides"
    },
    {
      "label": "Edge offset",
      "value": "1 1/2\"",
      "unit": "in",
      "appliesTo": "edge, both sides"
    },
    {
      "label": "Minimum shoulder/lane width",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "MIN. TYP. dimension"
    },
    {
      "label": "Edge thickness",
      "value": "8\"",
      "unit": "in",
      "appliesTo": "left edge curb"
    },
    {
      "label": "Edge thickness",
      "value": "3\"",
      "unit": "in",
      "appliesTo": "right edge curb"
    },
    {
      "label": "Beam spacing",
      "value": "7'-6\"",
      "unit": "",
      "appliesTo": "beam 1-2, 2-3, 3-4, 4-5, 5-6 spacing, each"
    },
    {
      "label": "End overhang beam to edge",
      "value": "3'-0 1/2\"",
      "unit": "",
      "appliesTo": "left and right end overhangs"
    },
    {
      "label": "500A spacing",
      "value": "6 1/2",
      "unit": "in",
      "appliesTo": "500A bars"
    },
    {
      "label": "502 spacing",
      "value": "",
      "unit": "",
      "appliesTo": "502 bars, at every 500A"
    },
    {
      "label": "30-400A spacing note",
      "value": "30",
      "unit": "count",
      "appliesTo": "400A bars, spaced as shown"
    },
    {
      "label": "6-400A at equal spaces",
      "value": "6",
      "unit": "count",
      "appliesTo": "400A bars near edges"
    },
    {
      "label": "14-400A at equal spaces",
      "value": "14",
      "unit": "count",
      "appliesTo": "400A bars mid-span"
    },
    {
      "label": "Clear cover top",
      "value": "2 1/4\"",
      "unit": "in",
      "appliesTo": "top clear cover, CL."
    },
    {
      "label": "Clear cover bottom",
      "value": "1\"",
      "unit": "in",
      "appliesTo": "bottom clear cover, CL."
    },
    {
      "label": "Side clear spacing typ",
      "value": "3\"",
      "unit": "in",
      "appliesTo": "typical spacing between bar groups"
    },
    {
      "label": "Edge vertical dimension",
      "value": "4 3/8\"",
      "unit": "in",
      "appliesTo": "left and right edge vertical dim"
    },
    {
      "label": "Drip bead size",
      "value": "3/4\"",
      "unit": "in",
      "appliesTo": "triangular drip bead"
    },
    {
      "label": "Diaphragm bar spacing offset",
      "value": "5\"",
      "unit": "in",
      "appliesTo": "403A bar group offset, both sides"
    },
    {
      "label": "403A bar count",
      "value": "7",
      "unit": "count",
      "appliesTo": "403A bars at equal spaces"
    },
    {
      "label": "402A bar count",
      "value": "4",
      "unit": "count",
      "appliesTo": "402A bars"
    },
    {
      "label": "507A bar count",
      "value": "2",
      "unit": "count",
      "appliesTo": "507A bars"
    },
    {
      "label": "Plain bar diameter",
      "value": "1\"",
      "unit": "in",
      "appliesTo": "plain bar in diaphragm"
    },
    {
      "label": "Cross slope",
      "value": "2",
      "unit": "%",
      "appliesTo": "deck slab, both sections"
    }
  ],
  "notes": [
    "DIMENSION \"D\" IS MEASURED FROM TOP OF SLAB TO TOP OF BEAMS AT CENTERLINE BEARING. VARY \"D\" BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTION, AND VERTICAL CURVE.",
    "MAINTAIN A CONSTANT SLAB THICKNESS OF 7 3/4\" BETWEEN BEAMS AND 8\" IN THE OVERHANGS.",
    "\"D\" = 8 3/4\" INTERIOR BEAMS",
    "\"D\" = 9 1/8\" EXTERIOR BEAMS",
    "FENCE NOT SHOWN, TYP.",
    "REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.",
    "3/4\" TRIANGULAR DRIP BEAD FULL LENGTH OF BRIDGE, TYP."
  ],
  "labels": [
    "SECTION THRU SLAB",
    "SECTION THRU DIAPHRAGM",
    "SR 21 WB = PGL",
    "C BEAM 1",
    "C BEAM 2",
    "C BEAM 3",
    "C BEAM 4",
    "C BEAM 5",
    "C BEAM 6"
  ],
  "description": "This crop contains two bridge deck cross sections: a 'SECTION THRU SLAB' showing six precast beams supporting a cast-in-place concrete deck slab with cross slope, overhangs, edge curbs, and detailed reinforcement (400A, 500A, 501, 502) with clear cover callouts and beam spacing dimensions; and a 'SECTION THRU DIAPHRAGM' below it showing intermediate diaphragms between the same six beams with reinforcement (403A, 402A, 507A) and a 1\" diameter plain bar. Together these document the deck slab thickness, camber/build-up dimension \"D\" for interior/exterior beams, overall deck geometry, and diaphragm reinforcement layout for this bridge span."
}

p07_r01Cross Section

  • Diaphragm×5rectangularreinforced concreteintermediate diaphragms between beams, shown in second section view

7 3/4 in Slab thickness between beams8 in Slab thickness in overhangs8 3/4 in Dimension D, interior beams9 1/8 in Dimension D, exterior beams22'-0" Overall width43'-7" Out to out width14'-2 1/2" Right side width40'-0" Gutter to gutter+25 more

crop

p07_r04

page 7 · other_p07_r04
Original
p07_r04
{
  "view": "Detail",
  "objects": [
    {
      "name": "PSC beam",
      "tag": "",
      "shape": "rectangular (elevation showing horizontal strand rows)",
      "material": "precast concrete",
      "count": 1,
      "note": "Shown in elevation with 'TOP OF BEAM' callout and horizontal strand/rebar lines"
    },
    {
      "name": "Concrete diaphragm",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "10\" wide diaphragm at beam, with reinforcement cage detailed"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507A",
      "shape": "",
      "material": "reinforcing steel",
      "count": 2,
      "note": "Appears twice (top and bottom pairs, '2-507A' each)"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402A",
      "shape": "",
      "material": "reinforcing steel",
      "count": 4,
      "note": "'4-402A' diagonal/vertical bars within diaphragm cage"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403A",
      "shape": "",
      "material": "reinforcing steel",
      "count": null,
      "note": "Labeled bar within cage, count not explicitly given"
    },
    {
      "name": "Plain bar",
      "tag": "",
      "shape": "circular",
      "material": "plain round bar",
      "count": null,
      "note": "1\" DIA. PLAIN BAR, shown as dot marker in cage"
    }
  ],
  "measurements": [
    {
      "label": "Top cover",
      "value": "2",
      "unit": "in",
      "appliesTo": "beam/diaphragm top edge"
    },
    {
      "label": "Overall height",
      "value": "2'-4\"",
      "unit": "ft-in",
      "appliesTo": "beam segment shown"
    },
    {
      "label": "Diaphragm width",
      "value": "10\"",
      "unit": "in",
      "appliesTo": "Concrete diaphragm"
    },
    {
      "label": "Clear cover",
      "value": "1 1/2\"",
      "unit": "in",
      "appliesTo": "reinforcement cage, typical"
    },
    {
      "label": "Plain bar diameter",
      "value": "1\"",
      "unit": "in",
      "appliesTo": "plain bar"
    }
  ],
  "notes": [],
  "labels": [
    "10\" CONC. DIAPH.",
    "TOP OF BEAM",
    "1 1/2\" CL. TYP.",
    "403A",
    "1\" DIA. PLAIN BAR",
    "2-507A",
    "4-402A"
  ],
  "description": "This crop is a detail elevation of a precast concrete beam end at a diaphragm location, showing the concrete diaphragm width, cover dimensions, and the reinforcement cage layout (bars 507A, 402A, 403A, and a 1\" diameter plain bar) embedded at the diaphragm. It documents beam-diaphragm reinforcement detailing rather than an overall structure view."
}

p07_r04Detail

  • Concrete diaphragm×1rectangularreinforced concrete10" wide diaphragm at beam, with reinforcement cage detailed

2 in Top cover2'-4" ft-in Overall height10" in Diaphragm width1 1/2" in Clear cover1" in Plain bar diameter

Page 9

crop

p09_r01 section thru slab

page 9 · gdot_plan_649084f395824aaebf1f5ed48132696f_p09_r01_section_thru_slab
Original
p09_r01 section thru slab
{
  "view": "Cross Section",
  "objects": [
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "flat with 2% cross slope",
      "material": "reinforced concrete",
      "count": 1,
      "note": "7 3/4\" thick between beams, 8\" in overhangs"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 1 through BEAM 6",
      "shape": "bulb-tee / I-section (tapered web)",
      "material": "precast concrete",
      "count": 6,
      "note": "spaced at 7'-6\" typical"
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "rectangular between beams",
      "material": "reinforced concrete",
      "count": 5,
      "note": "shown in Section Thru Diaphragm, with reinforcement 7-403B, 4-402B, 2-507B"
    },
    {
      "name": "Fence",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "noted as 'FENCE NOT SHOWN, TYP.' at both bridge edges"
    },
    {
      "name": "Reinforcement bar",
      "tag": "502",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "at every 500A"
    },
    {
      "name": "Reinforcement bar",
      "tag": "500A",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "spaced at 6 3/4\""
    },
    {
      "name": "Reinforcement bar",
      "tag": "501",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "under every 500A"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400B and C",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "30 total spaced as shown across slab; also 6 and 13 bar groups at ends/middle spans"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 7,
      "note": "at equal spaces, in diaphragm section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 4,
      "note": "in diaphragm section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 2,
      "note": "appears twice in diaphragm section (2 sets of 2)"
    },
    {
      "name": "Plain bar",
      "tag": "",
      "shape": "round, 1\" diameter",
      "material": "plain steel bar",
      "count": null,
      "note": "labeled '1\" DIAMETER PLAIN BAR' in diaphragm section"
    },
    {
      "name": "Drip bead",
      "tag": "",
      "shape": "triangular",
      "material": "",
      "count": 1,
      "note": "3/4\" triangular drip bead full length of bridge, typ., at deck edge"
    },
    {
      "name": "Construction joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 1,
      "note": "required construction joint parallel with deck, typ."
    }
  ],
  "measurements": [
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Width between fence lines",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Distance from PGL to edge",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Distance PGL to point",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Min shoulder/clear width",
      "value": "3'-0\"",
      "unit": "MIN.",
      "appliesTo": "deck slab, near right edge"
    },
    {
      "label": "Edge overhang dimension",
      "value": "1'-8\"",
      "unit": "",
      "appliesTo": "deck slab overhang, both sides"
    },
    {
      "label": "Edge thickness",
      "value": "1 1/2\"",
      "unit": "",
      "appliesTo": "deck slab edge, both sides"
    },
    {
      "label": "Beam top height typ.",
      "value": "8\"",
      "unit": "",
      "appliesTo": "beam, typ., both sides"
    },
    {
      "label": "Drip bead offset",
      "value": "3\"",
      "unit": "",
      "appliesTo": "deck edge, right side"
    },
    {
      "label": "Construction joint offset",
      "value": "8\"",
      "unit": "",
      "appliesTo": "deck edge, right side"
    },
    {
      "label": "Slab thickness",
      "value": "7 3/4\"",
      "unit": "",
      "appliesTo": "deck slab, between beams"
    },
    {
      "label": "Clear cover",
      "value": "2 1/4\"",
      "unit": "CL.",
      "appliesTo": "deck slab top reinforcement"
    },
    {
      "label": "Clear cover",
      "value": "1\"",
      "unit": "CL.",
      "appliesTo": "deck slab bottom reinforcement"
    },
    {
      "label": "Cross slope",
      "value": "2",
      "unit": "%",
      "appliesTo": "deck slab"
    },
    {
      "label": "Beam spacing",
      "value": "7'-6\"",
      "unit": "",
      "appliesTo": "BEAM 1 to BEAM 6, typical spacing, 5 spaces shown"
    },
    {
      "label": "Overhang end dimension",
      "value": "3'-0 1/2\"",
      "unit": "",
      "appliesTo": "deck slab, both ends"
    },
    {
      "label": "Rebar group spacing",
      "value": "3\"",
      "unit": "",
      "appliesTo": "400B and C bars, typ. at multiple locations"
    },
    {
      "label": "Edge stirrup spacing",
      "value": "4 3/8\"",
      "unit": "",
      "appliesTo": "6-400B and C group, both ends"
    },
    {
      "label": "500A bar spacing",
      "value": "6 3/4\"",
      "unit": "",
      "appliesTo": "500A bars"
    },
    {
      "label": "400B and C bar count",
      "value": "30",
      "unit": "",
      "appliesTo": "400B and C, spaced as shown"
    },
    {
      "label": "400B and C bar count",
      "value": "6",
      "unit": "",
      "appliesTo": "400B and C at eq. sps, near ends"
    },
    {
      "label": "400B and C bar count",
      "value": "13",
      "unit": "",
      "appliesTo": "400B and C at equal spaces, typ., middle spans"
    },
    {
      "label": "D dimension - interior beams",
      "value": "8 3/4\"",
      "unit": "",
      "appliesTo": "D, interior beams"
    },
    {
      "label": "D dimension - exterior beams",
      "value": "9 1/4\"",
      "unit": "",
      "appliesTo": "D, exterior beams"
    },
    {
      "label": "403B rebar count",
      "value": "7",
      "unit": "",
      "appliesTo": "403B, diaphragm section"
    },
    {
      "label": "403B end offset",
      "value": "5\"",
      "unit": "",
      "appliesTo": "403B, diaphragm section, both sides"
    },
    {
      "label": "402B rebar count",
      "value": "4",
      "unit": "",
      "appliesTo": "402B, diaphragm section"
    },
    {
      "label": "507B rebar count",
      "value": "2",
      "unit": "",
      "appliesTo": "507B, diaphragm section, each occurrence"
    },
    {
      "label": "Cross slope",
      "value": "2",
      "unit": "%",
      "appliesTo": "diaphragm section"
    }
  ],
  "notes": [
    "DIMENSION \"D\" IS MEASURED FROM TOP OF SLAB TO TOP OF BEAMS AT CENTERLINE BEARING. VARY \"D\" BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTION, AND VERTICAL CURVE.",
    "MAINTAIN A CONSTANT SLAB THICKNESS OF 7 3/4\" BETWEEN BEAMS AND 8\" IN THE OVERHANGS.",
    "\"D\" = 8 3/4\" INTERIOR BEAMS",
    "\"D\" = 9 1/4\" EXTERIOR BEAMS",
    "FENCE NOT SHOWN, TYP.",
    "30-400B AND C SPACED AS SHOWN",
    "502 AT EVERY 500A, TYP.",
    "500A AT 6 3/4\"",
    "501 UNDER EVERY 500A",
    "13-400B AND C AT EQUAL SPACES, TYP.",
    "6-400B AND C AT EQ. SPS.",
    "REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.",
    "¾\" TRIANGULAR DRIP BEAD FULL LENGTH OF BRIDGE, TYP.",
    "7-403B AT EQUAL SPACES",
    "1\" DIAMETER PLAIN BAR"
  ],
  "labels": [
    "SECTION THRU SLAB",
    "SECTION THRU DIAPHRAGM",
    "SR 21 WB = PGL",
    "C BEAM 1",
    "C BEAM 2",
    "C BEAM 3",
    "C BEAM 4",
    "C BEAM 5",
    "C BEAM 6"
  ],
  "description": "This crop shows two cross sections of a precast concrete beam bridge superstructure: an upper 'Section Thru Slab' depicting the full deck width with six PSC beams (Beam 1 through Beam 6), slab reinforcement details, overhangs, fence notes, and dimension callouts including deck widths, slab thicknesses, clear cover, and beam spacing; and a lower 'Section Thru Diaphragm' showing the intermediate diaphragms between beams with reinforcement bars 403B, 402B, 507B, and a 1\" diameter plain bar. Together these views document the deck slab geometry, beam layout, cross slope, and diaphragm reinforcement for this bridge structure."
}

p09_r01 section thru slabCross Section

  • Diaphragm×5rectangular between beamsreinforced concreteshown in Section Thru Diaphragm, with reinforcement 7-403B, 4-402B, 2-507B

43'-7" Out to out width40'-0" Gutter to gutter width34'-0" Width between fence lines22'-0" Distance from PGL to edge6'-0" Distance PGL to point3'-0" MIN. Min shoulder/clear width1'-8" Edge overhang dimension1 1/2" Edge thickness+22 more

crop

p09_r03 detail a

page 9 · gdot_plan_649084f395824aaebf1f5ed48132696f_p09_r03_detail_a
Original
p09_r03 detail a
{
  "view": "Section",
  "objects": [
    {
      "name": "Edge beam",
      "tag": "",
      "shape": "rectangular with tapered haunch",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Section thru edge beam at Bent 2, Bent 3 similar; shows preformed joint filler and construction joint"
    },
    {
      "name": "Bearing pad",
      "tag": "",
      "shape": "rectangular",
      "material": "elastomeric (implied)",
      "count": null,
      "note": "Noted as 'not shown' in this section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "506A",
      "shape": "bent bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "Spaced at 18\" per note"
    },
    {
      "name": "Reinforcement bar",
      "tag": "800",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 2,
      "note": "2-800 bars shown"
    },
    {
      "name": "Reinforcement bar",
      "tag": "508",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "509",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "404",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "801",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 1,
      "note": "1-801 bar"
    },
    {
      "name": "Reinforcement bar",
      "tag": "802",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 1,
      "note": "1-802 bar"
    },
    {
      "name": "Joint filler",
      "tag": "*",
      "shape": "strip",
      "material": "preformed material",
      "count": 1,
      "note": "1\" preformed joint filler at construction joint"
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "10\" concrete diaphragm, Section thru diaphragm, Span 2"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 4,
      "note": "2-507B top and 2-507B bottom shown, total 4 visible"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402B",
      "shape": "bar, crossed/diagonal",
      "material": "reinforcing steel",
      "count": 4,
      "note": "4-402B bars"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Plain bar",
      "tag": "",
      "shape": "round, 1\" dia.",
      "material": "plain steel bar",
      "count": 1,
      "note": "1\" dia. plain bar noted"
    },
    {
      "name": "Joint sealer detail",
      "tag": "Detail A",
      "shape": "notched joint profile",
      "material": "silicone sealant (Type B, C or D)",
      "count": 1,
      "note": "Detail A shows required construction joint with silicone sealant type joint sealer"
    }
  ],
  "measurements": [
    {
      "label": "width",
      "value": "8",
      "unit": "in",
      "appliesTo": "edge beam section, left overhang"
    },
    {
      "label": "width",
      "value": "1'-0 1/2",
      "unit": "",
      "appliesTo": "edge beam section"
    },
    {
      "label": "width",
      "value": "1'-0 1/2",
      "unit": "",
      "appliesTo": "edge beam section"
    },
    {
      "label": "width",
      "value": "8",
      "unit": "in",
      "appliesTo": "edge beam section, right overhang"
    },
    {
      "label": "clearance",
      "value": "4",
      "unit": "in",
      "appliesTo": "top cover, edge beam"
    },
    {
      "label": "depth",
      "value": "8",
      "unit": "in",
      "appliesTo": "haunch/taper, edge beam"
    },
    {
      "label": "spacing",
      "value": "18",
      "unit": "in",
      "appliesTo": "506A bar spacing"
    },
    {
      "label": "clearance",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "clearance, 3 sides, edge beam stirrup"
    },
    {
      "label": "width",
      "value": "1'-0",
      "unit": "",
      "appliesTo": "edge beam section, left dimension"
    },
    {
      "label": "width",
      "value": "1'-0",
      "unit": "",
      "appliesTo": "edge beam section, right dimension"
    },
    {
      "label": "joint filler thickness",
      "value": "1",
      "unit": "in",
      "appliesTo": "preformed joint filler"
    },
    {
      "label": "scale",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "Section thru edge beam"
    },
    {
      "label": "height",
      "value": "3'-0",
      "unit": "",
      "appliesTo": "diaphragm section overall depth"
    },
    {
      "label": "clearance",
      "value": "2",
      "unit": "in",
      "appliesTo": "top clearance, diaphragm section"
    },
    {
      "label": "width",
      "value": "10",
      "unit": "in",
      "appliesTo": "concrete diaphragm width"
    },
    {
      "label": "clearance",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "clearance typical, diaphragm reinforcement"
    },
    {
      "label": "diameter",
      "value": "1",
      "unit": "in",
      "appliesTo": "plain bar diameter"
    },
    {
      "label": "scale",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "Section thru diaphragm"
    },
    {
      "label": "width",
      "value": "1/4",
      "unit": "in",
      "appliesTo": "Detail A joint profile"
    },
    {
      "label": "width",
      "value": "1/2",
      "unit": "in",
      "appliesTo": "Detail A joint profile"
    },
    {
      "label": "width",
      "value": "3/4",
      "unit": "in",
      "appliesTo": "Detail A required construction joint width"
    },
    {
      "label": "radius",
      "value": "1/4",
      "unit": "in",
      "appliesTo": "Detail A rounding radius"
    }
  ],
  "notes": [
    "SLAB REINFORCEMENT NOT SHOWN",
    "BEARING PADS NOT SHOWN",
    "* 1\" PREFORMED JOINT FILLER",
    "BENT 2 SHOWN",
    "BENT 3 SIMILAR",
    "1 1/2\" CL. 3 SIDES",
    "1\" DIA. PLAIN BAR",
    "SILICONE SEALANT TYPE JOINT SEALER (TYPE B, C OR D)",
    "ROUND TO 1/4\" R",
    "REQUIRED CONST. JOINT., TYP.",
    "SEE DETAIL \"A\""
  ],
  "labels": [
    "SECTION THRU EDGE BEAM",
    "SECTION THRU DIAPHRAGM",
    "SPAN 2",
    "DETAIL \"A\"",
    "NO SCALE",
    "SCALE: 3/4\" = 1'-0\"",
    "C REQ'D. CONST. JOINT",
    "TOP OF BEAM",
    "10\" CONC. DIAPH."
  ],
  "description": "This crop contains three related structural details for a bridge superstructure: a Section thru Edge Beam at Bent 2 (Bent 3 similar) showing beam haunch geometry, reinforcement bars (506A, 800, 508, 509, 404, 801, 802), preformed joint filler, and a required construction joint; a Section thru Diaphragm for Span 2 showing a 10-inch concrete diaphragm with reinforcement (507B, 402B, 403B) and a 1-inch diameter plain bar; and Detail 'A' (no scale) illustrating a required construction joint with silicone sealant joint sealer dimensions. Slab reinforcement and bearing pads are explicitly noted as not shown in these sections."
}

p09_r03 detail aSection

  • Diaphragm×1rectangularreinforced concrete10" concrete diaphragm, Section thru diaphragm, Span 2

8 in width1'-0 1/2 width1'-0 1/2 width8 in width4 in clearance8 in depth18 in spacing1 1/2 in clearance+14 more

crop

p09_r01

page 9 · other_p09_r01
Original
p09_r01
{
  "view": "Cross Section",
  "objects": [
    {
      "name": "Deck slab",
      "tag": "",
      "shape": "tapered/crowned rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "7¾\" thick between beams, 8\" thick in overhangs, 2% cross slope"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 1",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": "centerline shown, 7'-6\" spacing"
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 2",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 3",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 4",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 5",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "PSC beam",
      "tag": "BEAM 6",
      "shape": "bulb-tee/I-section (tapered web)",
      "material": "precast concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 5,
      "note": "shown between beams in Section Thru Diaphragm, with 7-403B bars at equal spaces and 1\" diameter plain bar"
    },
    {
      "name": "Fence",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 0,
      "note": "labeled 'FENCE NOT SHOWN, TYP.' at both edges — present but not drawn"
    },
    {
      "name": "Reinforcement bar",
      "tag": "502",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "placed at every 500A, typ."
    },
    {
      "name": "Reinforcement bar",
      "tag": "500A",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "spaced at 6¾\""
    },
    {
      "name": "Reinforcement bar",
      "tag": "501",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "under every 500A"
    },
    {
      "name": "Reinforcement bar",
      "tag": "400B and C",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": null,
      "note": "30 bars spaced as shown at midspan; 6 bars at eq. sps. at each overhang; 13 bars at equal spaces near beam 3-4 area"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 7,
      "note": "at equal spaces, in diaphragm section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 4,
      "note": "in diaphragm section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507B",
      "shape": "bar",
      "material": "reinforcing steel",
      "count": 2,
      "note": "appears twice in diaphragm section"
    },
    {
      "name": "Plain bar",
      "tag": "",
      "shape": "circular (1\" diameter)",
      "material": "steel (plain, unreinforced)",
      "count": null,
      "note": "1\" diameter plain bar shown in diaphragm section"
    },
    {
      "name": "Drip bead",
      "tag": "",
      "shape": "triangular",
      "material": "",
      "count": 1,
      "note": "¾\" triangular drip bead, full length of bridge, typ."
    },
    {
      "name": "Construction joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 1,
      "note": "required construction joint parallel with deck, typ."
    }
  ],
  "measurements": [
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Width between beams 1-6",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Half width to PGL",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "deck cross section"
    },
    {
      "label": "Distance to lane edge",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "deck cross section"
    },
    {
      "label": "Overhang edge dimension",
      "value": "1'-8\"",
      "unit": "",
      "appliesTo": "deck overhang (both sides)"
    },
    {
      "label": "Edge thickness",
      "value": "1 1/2\"",
      "unit": "",
      "appliesTo": "deck edge (both sides)"
    },
    {
      "label": "Slab thickness (between beams)",
      "value": "7 3/4\"",
      "unit": "",
      "appliesTo": "deck slab"
    },
    {
      "label": "Slab thickness (overhangs)",
      "value": "8\"",
      "unit": "",
      "appliesTo": "deck slab overhangs"
    },
    {
      "label": "Clear cover (top)",
      "value": "2 1/4\"",
      "unit": "",
      "appliesTo": "reinforcement clearance"
    },
    {
      "label": "Clear cover (bottom)",
      "value": "1\"",
      "unit": "",
      "appliesTo": "reinforcement clearance"
    },
    {
      "label": "'D' dimension interior beams",
      "value": "8 3/4\"",
      "unit": "",
      "appliesTo": "interior beams"
    },
    {
      "label": "'D' dimension exterior beams",
      "value": "9 1/4\"",
      "unit": "",
      "appliesTo": "exterior beams"
    },
    {
      "label": "Cross slope",
      "value": "2",
      "unit": "%",
      "appliesTo": "deck slab"
    },
    {
      "label": "Overhang bar spacing group",
      "value": "6-400B and C",
      "unit": "",
      "appliesTo": "overhang, at each end"
    },
    {
      "label": "Overhang edge offset",
      "value": "3\"",
      "unit": "",
      "appliesTo": "beam to edge spacing, typ."
    },
    {
      "label": "Beam edge distance",
      "value": "4 3/8\"",
      "unit": "",
      "appliesTo": "end overhang detail"
    },
    {
      "label": "End overhang length",
      "value": "3'-0 1/2\"",
      "unit": "",
      "appliesTo": "end overhangs"
    },
    {
      "label": "Beam spacing",
      "value": "7'-6\"",
      "unit": "",
      "appliesTo": "beam centerline spacing, repeated 5 times"
    },
    {
      "label": "Bar spacing group",
      "value": "13-400B and C",
      "unit": "",
      "appliesTo": "at equal spaces between beams 3-4"
    },
    {
      "label": "Min. spacing",
      "value": "3'-0\" MIN.",
      "unit": "",
      "appliesTo": "typical spacing near right overhang"
    },
    {
      "label": "Diaphragm bar spacing",
      "value": "5\"",
      "unit": "",
      "appliesTo": "diaphragm section, both sides"
    },
    {
      "label": "Diaphragm bar group",
      "value": "7-403B",
      "unit": "",
      "appliesTo": "at equal spaces, diaphragm"
    },
    {
      "label": "Drip bead size",
      "value": "3/4",
      "unit": "in (triangular)",
      "appliesTo": "drip bead, full length of bridge"
    },
    {
      "label": "Edge deck thickness",
      "value": "8\"",
      "unit": "",
      "appliesTo": "right side edge detail"
    },
    {
      "label": "Right edge width",
      "value": "3\"",
      "unit": "",
      "appliesTo": "right edge detail"
    }
  ],
  "notes": [
    "DIMENSION \"D\" IS MEASURED FROM TOP OF SLAB TO TOP OF BEAMS AT CENTERLINE BEARING. VARY \"D\" BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTION, AND VERTICAL CURVE.",
    "MAINTAIN A CONSTANT SLAB THICKNESS OF 7 3/4\" BETWEEN BEAMS AND 8\" IN THE OVERHANGS.",
    "\"D\" = 8 3/4\" INTERIOR BEAMS",
    "\"D\" = 9 1/4\" EXTERIOR BEAMS",
    "FENCE NOT SHOWN, TYP.",
    "REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.",
    "3/4\" TRIANGULAR DRIP BEAD FULL LENGTH OF BRIDGE, TYP.",
    "502 AT EVERY 500A, TYP.",
    "30-400B AND C SPACED AS SHOWN",
    "500A AT 6 3/4\"",
    "501 UNDER EVERY 500A",
    "13-400B AND C AT EQUAL SPACES, TYP.",
    "6-400B AND C AT EQ. SPS.",
    "7-403B AT EQUAL SPACES",
    "1\" DIAMETER PLAIN BAR"
  ],
  "labels": [
    "SECTION THRU SLAB",
    "SECTION THRU DIAPHRAGM",
    "SR 21 WB = PGL"
  ],
  "description": "This crop shows two related cross-sectional details of a precast concrete girder bridge superstructure: an overall 'Section Thru Slab' spanning six beam lines (Beam 1 through Beam 6) with full deck geometry, cross slope, overhang details, and reinforcement bar callouts (500A, 501, 502, 400B/C series); and below it a 'Section Thru Diaphragm' view showing the intermediate diaphragms cast between the bulb-tee beams with reinforcement bars (403B, 402B, 507B) and a 1\" diameter plain bar. Notes at the top define the variable haunch dimension 'D' at interior and exterior beams and specify constant slab thicknesses. This documents deck slab and diaphragm reinforcing and geometry for the bridge superstructure, part of the beam/slab framing plan sheet."
}

p09_r01Cross Section

  • Diaphragm×5rectangularreinforced concreteshown between beams in Section Thru Diaphragm, with 7-403B bars at equal spaces and 1" diameter plain bar

43'-7" Out to out width40'-0" Gutter to gutter width34'-0" Width between beams 1-622'-0" Half width to PGL6'-0" Distance to lane edge1'-8" Overhang edge dimension1 1/2" Edge thickness7 3/4" Slab thickness (between beams)+18 more

crop

p09_r03

page 9 · other_p09_r03
Original
p09_r03
{
  "view": "Detail",
  "objects": [
    {
      "name": "Edge beam",
      "tag": "",
      "shape": "rectangular with notched joint",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Section thru edge beam at Bent 2 (Bent 3 similar); shows construction joint, preformed joint filler, and reinforcement bars 506A, 800, 508, 509, 801/802, 404"
    },
    {
      "name": "Reinforcement bar",
      "tag": "506A",
      "shape": "bent bar",
      "material": "reinforced steel",
      "count": null,
      "note": "spaced at 18\" per printed callout"
    },
    {
      "name": "Reinforcement bar",
      "tag": "800",
      "shape": "bar",
      "material": "reinforced steel",
      "count": 2,
      "note": "2-800 shown at top of section"
    },
    {
      "name": "Reinforcement bar",
      "tag": "508",
      "shape": "bar",
      "material": "reinforced steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "509",
      "shape": "bar",
      "material": "reinforced steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "801",
      "shape": "bar",
      "material": "reinforced steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "802",
      "shape": "bar",
      "material": "reinforced steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "Reinforcement bar",
      "tag": "404",
      "shape": "bar",
      "material": "reinforced steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Bearing pad",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": null,
      "note": "noted as 'not shown' in this section"
    },
    {
      "name": "Preformed joint filler",
      "tag": "*",
      "shape": "strip",
      "material": "",
      "count": null,
      "note": "1\" preformed joint filler at construction joint"
    },
    {
      "name": "Diaphragm",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Section thru diaphragm, Span 2, 10\" concrete diaphragm"
    },
    {
      "name": "Reinforcement bar",
      "tag": "507B",
      "shape": "stirrup/tie",
      "material": "reinforced steel",
      "count": 4,
      "note": "2-507B top and 2-507B bottom shown"
    },
    {
      "name": "Reinforcement bar",
      "tag": "402B",
      "shape": "bar",
      "material": "reinforced steel",
      "count": 4,
      "note": "4-402B diagonal bars"
    },
    {
      "name": "Reinforcement bar",
      "tag": "403B",
      "shape": "bar",
      "material": "reinforced steel",
      "count": null,
      "note": ""
    },
    {
      "name": "Plain bar",
      "tag": "",
      "shape": "round",
      "material": "steel",
      "count": 1,
      "note": "1\" dia. plain bar shown at center of diaphragm section"
    },
    {
      "name": "Joint sealer detail",
      "tag": "Detail A",
      "shape": "V-groove joint",
      "material": "silicone sealant",
      "count": 1,
      "note": "Detail A - silicone sealant type joint sealer (Type B, C or D) at required construction joint"
    }
  ],
  "measurements": [
    {
      "label": "width",
      "value": "8",
      "unit": "in",
      "appliesTo": "Section thru edge beam"
    },
    {
      "label": "width",
      "value": "1'-0 1/2",
      "unit": "ft-in",
      "appliesTo": "Section thru edge beam"
    },
    {
      "label": "width",
      "value": "1'-0 1/2",
      "unit": "ft-in",
      "appliesTo": "Section thru edge beam"
    },
    {
      "label": "width",
      "value": "8",
      "unit": "in",
      "appliesTo": "Section thru edge beam"
    },
    {
      "label": "clearance",
      "value": "4",
      "unit": "in",
      "appliesTo": "506A/2-800 area, top clearance"
    },
    {
      "label": "depth",
      "value": "8",
      "unit": "in",
      "appliesTo": "801/802 bar region"
    },
    {
      "label": "clearance",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "508/509/404 region, 3 sides"
    },
    {
      "label": "width",
      "value": "1'-0",
      "unit": "ft",
      "appliesTo": "lower slab section left"
    },
    {
      "label": "width",
      "value": "1'-0",
      "unit": "ft",
      "appliesTo": "lower slab section right"
    },
    {
      "label": "height",
      "value": "3'-0",
      "unit": "ft",
      "appliesTo": "Section thru diaphragm"
    },
    {
      "label": "clearance",
      "value": "2",
      "unit": "in",
      "appliesTo": "Section thru diaphragm top"
    },
    {
      "label": "clearance",
      "value": "1 1/2",
      "unit": "in",
      "appliesTo": "403B/402B region, typical"
    },
    {
      "label": "width",
      "value": "10",
      "unit": "in",
      "appliesTo": "concrete diaphragm width"
    },
    {
      "label": "depth",
      "value": "1/4",
      "unit": "in",
      "appliesTo": "Detail A joint groove"
    },
    {
      "label": "depth",
      "value": "1/2",
      "unit": "in",
      "appliesTo": "Detail A joint groove"
    },
    {
      "label": "width",
      "value": "3/4",
      "unit": "in",
      "appliesTo": "Detail A joint groove width"
    },
    {
      "label": "radius",
      "value": "1/4",
      "unit": "in",
      "appliesTo": "Detail A round to R"
    },
    {
      "label": "scale",
      "value": "3/4\"=1'-0",
      "unit": "",
      "appliesTo": "Section thru edge beam"
    },
    {
      "label": "scale",
      "value": "3/4\"=1'-0",
      "unit": "",
      "appliesTo": "Section thru diaphragm"
    },
    {
      "label": "scale",
      "value": "NO SCALE",
      "unit": "",
      "appliesTo": "Detail A"
    }
  ],
  "notes": [
    "SEE DETAIL \"A\"",
    "SLAB REINFORCEMENT NOT SHOWN",
    "* 1\" PREFORMED JOINT FILLER",
    "BEARING PADS NOT SHOWN",
    "BENT 2 SHOWN, BENT 3 SIMILAR",
    "1 1/2\" CL., TYP.",
    "1\" DIA. PLAIN BAR",
    "SILICONE SEALANT TYPE JOINT SEALER (TYPE B, C OR D)",
    "ROUND TO 1/4\" R",
    "REQUIRED CONST. JOINT., TYP.",
    "C REQ'D. CONST. JOINT"
  ],
  "labels": [
    "SECTION THRU EDGE BEAM",
    "SECTION THRU DIAPHRAGM",
    "DETAIL \"A\"",
    "SPAN 2",
    "TOP OF BEAM",
    "10\" CONC. DIAPH."
  ],
  "description": "This crop shows three related reinforced-concrete details for a bridge superstructure: a cross section through the edge beam at Bent 2 (with Bent 3 similar) showing reinforcement bars (506A, 800, 508, 509, 801, 802, 404), a required construction joint with preformed joint filler, and a note that bearing pads are not shown; a cross section through a diaphragm at Span 2 showing a 10\" concrete diaphragm with stirrups (507B), diagonal bars (402B, 403B) and a 1\" diameter plain bar; and a small no-scale Detail 'A' illustrating the silicone sealant joint sealer profile at a required construction joint. Slab reinforcement is explicitly noted as not shown in both main sections."
}

p09_r03Detail

  • Diaphragm×1rectangularreinforced concreteSection thru diaphragm, Span 2, 10" concrete diaphragm

8 in width1'-0 1/2 ft-in width1'-0 1/2 ft-in width8 in width4 in clearance8 in depth1 1/2 in clearance1'-0 ft width+12 more

Page 10

crop

p10_r04 tighten diaphragm bar as per sub section

page 10 · gdot_plan_649084f395824aaebf1f5ed48132696f_p10_r04_tighten_diaphragm_bar_as_per_sub_section
Original
p10_r04 tighten diaphragm bar as per sub section
{
  "view": "Detail",
  "objects": [
    {
      "name": "Diaphragm bar",
      "tag": "☉",
      "shape": "circular (bar)",
      "material": "structural steel (ASTM A709 Grade 36)",
      "count": 1,
      "note": "1\" diameter plain bar, threaded 5\" on each end, shown passing through beam with washer and hex nut, recessed and cut off"
    },
    {
      "name": "Beam / diaphragm concrete section",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 2,
      "note": "two concrete faces shown with a break line, representing beam webs at diaphragm location"
    },
    {
      "name": "Reinforcement bars",
      "tag": "351",
      "shape": "straight bars",
      "material": "reinforcing steel",
      "count": 4,
      "note": "4-#351 bars at 4\" each way, shown as small circular dots in section"
    },
    {
      "name": "Washer",
      "tag": "",
      "shape": "circular",
      "material": "steel",
      "count": 2,
      "note": "1/4\" x 3 1/2\" diameter washers at each threaded end of diaphragm bar"
    },
    {
      "name": "Hex nut",
      "tag": "",
      "shape": "hexagonal",
      "material": "steel",
      "count": 2,
      "note": "hex nuts at each threaded end of diaphragm bar"
    }
  ],
  "measurements": [
    {
      "label": "Clear distance",
      "value": "1",
      "unit": "in",
      "appliesTo": "beam face to diaphragm bar hole"
    },
    {
      "label": "Width",
      "value": "3",
      "unit": "in",
      "appliesTo": "recess/pocket dimension"
    },
    {
      "label": "Hole diameter",
      "value": "2",
      "unit": "in",
      "appliesTo": "hole for diaphragm bar"
    },
    {
      "label": "Diameter",
      "value": "5",
      "unit": "in",
      "appliesTo": "recess/pocket for washer and nut"
    },
    {
      "label": "Reinforcement spacing/count",
      "value": "4-351 AT 4\"",
      "unit": "in",
      "appliesTo": "reinforcement bars 351"
    },
    {
      "label": "Diaphragm bar diameter",
      "value": "1",
      "unit": "in",
      "appliesTo": "diaphragm bar (☉)"
    },
    {
      "label": "Threaded length",
      "value": "5",
      "unit": "in",
      "appliesTo": "diaphragm bar ends"
    },
    {
      "label": "Washer thickness x diameter",
      "value": "1/4 x 3 1/2",
      "unit": "in",
      "appliesTo": "washer on diaphragm bar"
    },
    {
      "label": "Cut off distance from beam face",
      "value": "1",
      "unit": "in",
      "appliesTo": "excess diaphragm bar"
    }
  ],
  "notes": [
    "☉ DIAPHRAGM BAR SHALL BE A 1\" DIAMETER PLAIN BAR, THREADED 5\" ON EACH END, WITH 1/4\" X 3 1/2\" DIAMETER WASHERS AND HEX NUTS (ASTM A 709 GRADE 36).",
    "TIGHTEN DIAPHRAGM BAR AS PER SUB-SECTION 507.3.05.C OF THE GEORGIA DOT SPECIFICATIONS.",
    "AFTER EXCESS DIAPHRAGM BAR HAS BEEN CUT OFF, PAINT DIAPHRAGM BAR, WASHER, AND NUT EXPOSED IN RECESS WITH SPECIAL PROTECTIVE COATING NO. 2 P AS PER SECTION 535 OF THE GEORGIA DOT SPECIFICATIONS. AFTER PAINTING, FILL THE RECESS WITH AN APPROVED EPOXY GROUT.",
    "GALVANIZING OF THE DIAPHRAGM BAR AS PER SUB-SECTION 865.2.01.B.12 OF THE GEORGIA DOT SPECIFICATIONS IS NOT REQUIRED.",
    "CUT OFF EXCESS DIAPHRAGM BAR 1\" FROM BEAM FACE."
  ],
  "labels": [
    "2\" DIAMETER HOLE",
    "4-351 AT 4\" EACH WAY",
    "1\" CL.",
    "3\"",
    "5\" DIA."
  ],
  "description": "This crop shows a detail of a diaphragm bar connection at a beam/diaphragm joint, including a threaded steel bar passing through a 2-inch diameter hole, secured with washers and hex nuts, and recessed 1 inch from the beam face. Accompanying notes specify the bar material, tightening procedure, painting/grouting requirements, and a note that galvanizing is not required per Georgia DOT specifications. Reinforcement bars (351) are shown embedded at 4-inch spacing each way around the bar location."
}

p10_r04 tighten diaphragm bar as per sub sectionDetail

  • Beam / diaphragm concrete section×2rectangularreinforced concretetwo concrete faces shown with a break line, representing beam webs at diaphragm location

1 in Clear distance3 in Width2 in Hole diameter5 in Diameter4-351 AT 4" in Reinforcement spacing/count1 in Diaphragm bar diameter5 in Threaded length1/4 x 3 1/2 in Washer thickness x diameter+1 more