Matched toPier Capbridge.substructure.pier_system.pier_capon “Cap Beam”
The model provider refused the call: the account is out of credit. Top up the OpenRouter key, or lower OPENAI_MAX_TOKENS.
| The class asks for | Unit | A reading with that name | From |
|---|---|---|---|
| LengthL | m/mm | no reading by that name | |
| WidthW | m/mm | no reading by that name | |
| ThicknessT | m/mm | no reading by that name | |
| Instance CountN | count | no reading by that name | |
| Concrete Gradefck | — | no reading by that name |
Paired on the measurement’s name only, which cannot know that three span lengths sum to the deck length. Step 3 works these out properly for every item it matches — reading every crop behind the item, deriving what the drawings imply and showing its arithmetic. This item has not had that pass yet; the button runs it for this one.
How the sheets named it
Notes on the sheets that carry it
- p132" MIN. CL.
- p132" CL. 3 SIDES
- p131'-0" TYP.
- p13B.F.P.R.
- p136'-0" MIN.
- p132'-0" MIN.
- p172-445 SERIES
- p172-442
- p174-1040
- p17441
- p17CAP
- p17COPING
- p17FRONT FACE OF WALL
Every crop it was read in — the drawing beside what the model took off it
Page 13
p13_r05 section b bSection
- Coping×1rectangularreinforced concreteCap element atop the wall
3'-0" ft-in Cap width2" MIN. in Clear cover2'-0" ft Vertical dimension1'-0" ft Typical spacing2" CL. 3 SIDES in Side clearance1'-6" ft-in Half width1'-6" ft-in Half width3/4" = 1'-0" Scale+4 more
p13_r05Section
- Coping×1rectangularreinforced concreteCap element atop wall, labeled COPING
3'-0" ft-in Cap width2" MIN. CL. in Clear cover top2'-0" MIN. ft-in Cap height (min)1'-0" TYP. ft-in Bar spacing typical2" CL. 3 SIDES in Clear cover 3 sides1'-6" ft-in Half-width dimension1'-6" ft-in Half-width dimension6'-0" MIN. ft-in Overall min width+2 more
Page 17
p17_r05 section b bSection
- Coping×1rectangularconcreteCap element atop wall
3'-0" ft-in Cap width2" MIN. CL. in Minimum clear cover to top bars2'-0" MIN. ft-in Minimum cap depth1'-0" ft-in Typical spacing2" CL. 3 SIDES in Clear cover 3 sides1'-6" ft-in Half-width dimension left1'-6" ft-in Half-width dimension right3/4" = 1'-0" Scale+4 more
p17_r05Section
- Coping×1rectangularreinforced concreteCap element atop the wall, labeled 'COPING'
3'-0" ft-in Cap width2" MIN. CL. in Clear cover top2'-0" MIN. ft-in Min. depth to bars1'-0" TYP. ft-in Typical spacing2" CL. 3 SIDES in Clear cover sides1'-6" ft-in Half-width dimension1'-6" ft-in Half-width dimension3/4" = 1'-0" Scale+4 more