Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

RCC Box Culvert

1 page · 2 crops · drainage

⚠ No class in the bridge ontology fits this itemAdd a class

The ontology would need an RCC box culvert class.

How the sheets named it

BC for cross roadR.C.C. box cast in situ portion

Every dimension read for it3

  • M35Concrete gradep1 · p01_r02 general design notes material grades and legend
  • 40mm mmMinimum BC thickness for cross roadp1 · p01_r02 general design notes material grades and legend
  • M35Concrete gradep1 · p01_r02

Notes on the sheets that carry it

  • p11. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
  • p12. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
  • p13. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
  • p14. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.
  • p15. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: c=0, φ 30°, γ = 20.0 T/m³.
  • p16. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- R.C.C. BOX CAST IN SITU PORTION — M35; CRASH BARRIER — M40; APPROACH SLAB — M30; GRADE OF PCC BELOW APPROACH SLAB — M15; GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX — M10.
  • p17. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).
  • p18. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
  • p19. THE STRUCTURE FALLS IN SEISMIC ZONE III.
  • p110. THE DESIGN ARE APPLICABLE FOR SEVERE CONDITIONS OF EXPOSURE.
  • p111. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.
  • p112. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS: BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm; BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm; TOP SLAB ON BOTH FACES = 45mm.
  • p114. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.
  • p115. THE ROW AT UNDERPASS LOCATION IS 6.0m.
  • p116. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY.
  • p15. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: C=0 . φ> 30°, γ = 2.0 T/m³.
  • p16. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-
  • p1• R.C.C. BOX CAST IN SITU PORTION ------ M35
  • p1• CRASH BARRIER ------ M40
  • p1• APPROACH SLAB ------ M30
  • p1• GRADE OF PCC BELOW APPROACH SLAB ------ M15
  • p1• GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX------ M10
  • p112. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS:
  • p1• BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm
  • p1• BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm
  • p1• TOP SLAB ON BOTH FACES = 45mm
  • p115. THE ROW AT UNDERPASS LOCATION IS 60m.

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r02 general design notes material grades and legend

page 1 · b_file_7c2c27cff2134dcfbedea68fcd7c18bc_p01_r02_general_design_notes_material_grades_and_legend
Original
p01_r02 general design notes material grades and legend
{
  "view": "Notes",
  "objects": [
    {
      "name": "filler type expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Specified in Note 4."
    },
    {
      "name": "selected earth fill",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Used for backfilling behind RE wall."
    },
    {
      "name": "RE wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Referenced as retaining the selected earth fill backfill."
    },
    {
      "name": "R.C.C. box cast in situ portion",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade stated as M35."
    },
    {
      "name": "crash barrier",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Concrete grade stated as M40; details referenced to miscellaneous drawings."
    },
    {
      "name": "approach slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Concrete grade stated as M30; PCC below is stated as M15."
    },
    {
      "name": "PCC below approach slab",
      "tag": "",
      "shape": "",
      "material": "PCC",
      "count": null,
      "note": "Concrete grade stated as M15."
    },
    {
      "name": "PCC below founding level of RCC box",
      "tag": "",
      "shape": "",
      "material": "PCC",
      "count": null,
      "note": "Concrete grade stated as M10."
    },
    {
      "name": "reinforcing steel bars",
      "tag": "",
      "shape": "",
      "material": "high yield strength deformed (TMT) steel",
      "count": null,
      "note": "Specified as Grade-Fe 550D."
    },
    {
      "name": "cover slab for footpath",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Details referenced to miscellaneous drawings."
    },
    {
      "name": "top slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Wearing course is specified over this slab."
    },
    {
      "name": "wearing course",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Provided over top slab."
    },
    {
      "name": "BC for cross road",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Minimum thickness specified."
    }
  ],
  "measurements": [
    {
      "label": "Scale",
      "value": "1:25",
      "unit": "",
      "appliesTo": "DETAIL Z"
    },
    {
      "label": "Filler type expansions joints width",
      "value": "20mm",
      "unit": "mm",
      "appliesTo": "filler type expansion joint"
    },
    {
      "label": "Selected earth fill cohesion",
      "value": "c=0",
      "unit": "",
      "appliesTo": "selected earth fill"
    },
    {
      "label": "Selected earth fill friction angle",
      "value": "φ 30°",
      "unit": "°",
      "appliesTo": "selected earth fill"
    },
    {
      "label": "Selected earth fill unit weight",
      "value": "γ = 20.0",
      "unit": "T/m³",
      "appliesTo": "selected earth fill"
    },
    {
      "label": "Concrete grade",
      "value": "M35",
      "unit": "",
      "appliesTo": "R.C.C. box cast in situ portion"
    },
    {
      "label": "Concrete grade",
      "value": "M40",
      "unit": "",
      "appliesTo": "crash barrier"
    },
    {
      "label": "Concrete grade",
      "value": "M30",
      "unit": "",
      "appliesTo": "approach slab"
    },
    {
      "label": "Concrete grade",
      "value": "M15",
      "unit": "",
      "appliesTo": "PCC below approach slab"
    },
    {
      "label": "Concrete grade",
      "value": "M10",
      "unit": "",
      "appliesTo": "PCC below founding level of RCC box"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "reinforcing steel bars"
    },
    {
      "label": "Clear cover at bottom slab and side wall earth faces",
      "value": "75mm",
      "unit": "mm",
      "appliesTo": "bottom slab & side wall"
    },
    {
      "label": "Clear cover at bottom slab and side wall inside faces",
      "value": "45mm",
      "unit": "mm",
      "appliesTo": "bottom slab & side wall"
    },
    {
      "label": "Clear cover at top slab on both faces",
      "value": "45mm",
      "unit": "mm",
      "appliesTo": "top slab"
    },
    {
      "label": "Wearing course thickness",
      "value": "50mm",
      "unit": "mm",
      "appliesTo": "wearing course"
    },
    {
      "label": "Minimum BC thickness for cross road",
      "value": "40mm",
      "unit": "mm",
      "appliesTo": "BC for cross road"
    },
    {
      "label": "ROW at underpass location",
      "value": "6.0m",
      "unit": "m",
      "appliesTo": "underpass location"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.",
    "5. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: c=0, φ 30°, γ = 20.0 T/m³.",
    "6. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- R.C.C. BOX CAST IN SITU PORTION — M35; CRASH BARRIER — M40; APPROACH SLAB — M30; GRADE OF PCC BELOW APPROACH SLAB — M15; GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX — M10.",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).",
    "8. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "9. THE STRUCTURE FALLS IN SEISMIC ZONE III.",
    "10. THE DESIGN ARE APPLICABLE FOR SEVERE CONDITIONS OF EXPOSURE.",
    "11. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.",
    "12. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS: BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm; BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm; TOP SLAB ON BOTH FACES = 45mm.",
    "14. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.",
    "15. THE ROW AT UNDERPASS LOCATION IS 6.0m.",
    "16. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY."
  ],
  "labels": [
    "DETAIL Z",
    "(SCALE 1:25)",
    "NOTES:",
    "LEGEND:",
    "FRL — FINISHED ROAD LEVEL",
    "CRL — CROSS ROAD LEVEL"
  ],
  "description": "This crop is a general notes block titled DETAIL Z, with a scale of 1:25. It documents design, material-grade, backfill, reinforcement cover, loading, exposure, road-level legend, and construction requirements for a structure including an RCC box, approach slab, crash barrier, and cross road."
}

p01_r02 general design notes material grades and legendNotes

  • R.C.C. box cast in situ portionreinforced concreteConcrete grade stated as M35.
  • BC for cross roadMinimum thickness specified.

1:25 Scale20mm mm Filler type expansions joints widthc=0 Selected earth fill cohesionφ 30° ° Selected earth fill friction angleγ = 20.0 T/m³ Selected earth fill unit weightM35 Concrete gradeM40 Concrete gradeM30 Concrete grade+9 more

crop

p01_r02

page 1 · design_notes_and_legend_p01_r02
Original
p01_r02
{
  "view": "Notes",
  "objects": [
    {
      "name": "Filler type expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Specified to be provided."
    },
    {
      "name": "Structure",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Backfilling is specified on both sides."
    },
    {
      "name": "R.E. wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Selected earth fill behind wall is specified."
    },
    {
      "name": "R.C.C. box cast in situ portion",
      "tag": "",
      "shape": "",
      "material": "concrete, M35",
      "count": null,
      "note": ""
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete, M40",
      "count": null,
      "note": "Reference miscellaneous drawings for details."
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete, M30",
      "count": null,
      "note": "PCC below approach slab is specified as M15."
    },
    {
      "name": "PCC below approach slab",
      "tag": "",
      "shape": "",
      "material": "PCC, M15",
      "count": null,
      "note": ""
    },
    {
      "name": "PCC below founding level of RCC box",
      "tag": "",
      "shape": "",
      "material": "PCC, M10",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcing steel bars",
      "tag": "",
      "shape": "",
      "material": "high yield strength deformed (TMT) bars, Grade-Fe 550D",
      "count": null,
      "note": ""
    },
    {
      "name": "Cover slab for footpath",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Reference miscellaneous drawings for details."
    },
    {
      "name": "Bottom slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Clear reinforcement cover is specified at earth and inside faces."
    },
    {
      "name": "Side wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Clear reinforcement cover is specified at earth and inside faces."
    },
    {
      "name": "Top slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Clear reinforcement cover and wearing course are specified."
    },
    {
      "name": "Wearing course",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Provided over top slab."
    },
    {
      "name": "BC for cross road",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Minimum thickness specified."
    }
  ],
  "measurements": [
    {
      "label": "Scale",
      "value": "1:25",
      "unit": "",
      "appliesTo": "DETAIL Z"
    },
    {
      "label": "Filler type expansion joint width",
      "value": "20",
      "unit": "mm",
      "appliesTo": "Filler type expansion joints"
    },
    {
      "label": "C",
      "value": "0",
      "unit": "",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "φ",
      "value": "> 30°",
      "unit": "",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "γ",
      "value": "2.0",
      "unit": "T/m³",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Concrete grade",
      "value": "M35",
      "unit": "",
      "appliesTo": "R.C.C. box cast in situ portion"
    },
    {
      "label": "Concrete grade",
      "value": "M40",
      "unit": "",
      "appliesTo": "Crash barrier"
    },
    {
      "label": "Concrete grade",
      "value": "M30",
      "unit": "",
      "appliesTo": "Approach slab"
    },
    {
      "label": "PCC grade",
      "value": "M15",
      "unit": "",
      "appliesTo": "PCC below approach slab"
    },
    {
      "label": "PCC grade",
      "value": "M10",
      "unit": "",
      "appliesTo": "PCC below founding level of RCC box"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "Reinforcing steel"
    },
    {
      "label": "Design loading",
      "value": "FOUR LANE OF CLASS A",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Design loading",
      "value": "ONE LANE CLASS 70R + TWO LANE OF CLASS A",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Design loading",
      "value": "ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Seismic zone",
      "value": "III",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Clear cover, bottom slab & side wall (earth faces)",
      "value": "75",
      "unit": "mm",
      "appliesTo": "Reinforcement"
    },
    {
      "label": "Clear cover, bottom slab & side wall (inside faces)",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Reinforcement"
    },
    {
      "label": "Clear cover, top slab on both faces",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Reinforcement"
    },
    {
      "label": "Wearing course thickness",
      "value": "50",
      "unit": "mm",
      "appliesTo": "Top slab"
    },
    {
      "label": "Minimum BC thickness",
      "value": "40",
      "unit": "mm",
      "appliesTo": "Cross road"
    },
    {
      "label": "ROW at underpass location",
      "value": "60",
      "unit": "m",
      "appliesTo": "Underpass location"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.",
    "5. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: C=0 . φ> 30°, γ = 2.0 T/m³.",
    "6. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-",
    "• R.C.C. BOX CAST IN SITU PORTION ------ M35",
    "• CRASH BARRIER ------ M40",
    "• APPROACH SLAB ------ M30",
    "• GRADE OF PCC BELOW APPROACH SLAB ------ M15",
    "• GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX------ M10",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).",
    "8. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "9. THE STRUCTURE FALLS IN SEISMIC ZONE III.",
    "10. THE DESIGN ARE APPLICABLE FOR “SEVERE” CONDITIONS OF EXPOSURE",
    "11. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.",
    "12. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS:",
    "• BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm",
    "• BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm",
    "• TOP SLAB ON BOTH FACES = 45mm",
    "14. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.",
    "15. THE ROW AT UNDERPASS LOCATION IS 60m.",
    "16. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY."
  ],
  "labels": [
    "DETAIL Z",
    "(SCALE 1:25)",
    "NOTES:",
    "LEGEND:",
    "1. FRL ........ FINISHED ROAD LEVEL",
    "2. CRL ........ CROSS ROAD LEVEL"
  ],
  "description": "This crop is a general notes block for a structure detail, headed DETAIL Z, together with a short level-abbreviation legend. It specifies design, materials, loading, backfill, reinforcement cover, slab surfacing, and approach-work requirements; no physical plan, elevation, or section geometry is shown in this crop."
}

p01_r02Notes

  • R.C.C. box cast in situ portionconcrete, M35
  • BC for cross roadMinimum thickness specified.

1:25 Scale20 mm Filler type expansion joint width0 C> 30° φ2.0 T/m³ γM35 Concrete gradeM40 Concrete gradeM30 Concrete grade+13 more