Drawing to BOQpipeline control sheet
← Mindmapwhat the drawings said

Expansion Joint

1 page · 3 crops · ×1 · deck

Matched toExpansion Joint Systembridge.superstructure.expansion_joint_systemcheckon “Expansion Joint”

This class asks for no measurements, so there is no take-off to do against it.

How the sheets named it

filler type expansion jointFiller type expansion jointexpansion gap

Every dimension read for it2

  • 20mm mmFiller type expansions joints widthp1 · p01_r02 general design notes material grades and legend
  • 10 mmgapp1 · p01_r04

Notes on the sheets that carry it

  • p11. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
  • p12. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
  • p13. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
  • p14. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.
  • p15. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: c=0, φ 30°, γ = 20.0 T/m³.
  • p16. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- R.C.C. BOX CAST IN SITU PORTION — M35; CRASH BARRIER — M40; APPROACH SLAB — M30; GRADE OF PCC BELOW APPROACH SLAB — M15; GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX — M10.
  • p17. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).
  • p18. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
  • p19. THE STRUCTURE FALLS IN SEISMIC ZONE III.
  • p110. THE DESIGN ARE APPLICABLE FOR SEVERE CONDITIONS OF EXPOSURE.
  • p111. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.
  • p112. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS: BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm; BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm; TOP SLAB ON BOTH FACES = 45mm.
  • p114. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.
  • p115. THE ROW AT UNDERPASS LOCATION IS 6.0m.
  • p116. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY.
  • p15. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: C=0 . φ> 30°, γ = 2.0 T/m³.
  • p16. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-
  • p1• R.C.C. BOX CAST IN SITU PORTION ------ M35
  • p1• CRASH BARRIER ------ M40
  • p1• APPROACH SLAB ------ M30
  • p1• GRADE OF PCC BELOW APPROACH SLAB ------ M15
  • p1• GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX------ M10
  • p112. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS:
  • p1• BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm
  • p1• BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm
  • p1• TOP SLAB ON BOTH FACES = 45mm
  • p115. THE ROW AT UNDERPASS LOCATION IS 60m.
  • p1COMPACTED NON-PLASTIC GRANULAR FILL (SAND/GRAVEL) (Ø>30°)

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r02 general design notes material grades and legend

page 1 · b_file_7c2c27cff2134dcfbedea68fcd7c18bc_p01_r02_general_design_notes_material_grades_and_legend
Original
p01_r02 general design notes material grades and legend
{
  "view": "Notes",
  "objects": [
    {
      "name": "filler type expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Specified in Note 4."
    },
    {
      "name": "selected earth fill",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Used for backfilling behind RE wall."
    },
    {
      "name": "RE wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Referenced as retaining the selected earth fill backfill."
    },
    {
      "name": "R.C.C. box cast in situ portion",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade stated as M35."
    },
    {
      "name": "crash barrier",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Concrete grade stated as M40; details referenced to miscellaneous drawings."
    },
    {
      "name": "approach slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Concrete grade stated as M30; PCC below is stated as M15."
    },
    {
      "name": "PCC below approach slab",
      "tag": "",
      "shape": "",
      "material": "PCC",
      "count": null,
      "note": "Concrete grade stated as M15."
    },
    {
      "name": "PCC below founding level of RCC box",
      "tag": "",
      "shape": "",
      "material": "PCC",
      "count": null,
      "note": "Concrete grade stated as M10."
    },
    {
      "name": "reinforcing steel bars",
      "tag": "",
      "shape": "",
      "material": "high yield strength deformed (TMT) steel",
      "count": null,
      "note": "Specified as Grade-Fe 550D."
    },
    {
      "name": "cover slab for footpath",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Details referenced to miscellaneous drawings."
    },
    {
      "name": "top slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Wearing course is specified over this slab."
    },
    {
      "name": "wearing course",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Provided over top slab."
    },
    {
      "name": "BC for cross road",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Minimum thickness specified."
    }
  ],
  "measurements": [
    {
      "label": "Scale",
      "value": "1:25",
      "unit": "",
      "appliesTo": "DETAIL Z"
    },
    {
      "label": "Filler type expansions joints width",
      "value": "20mm",
      "unit": "mm",
      "appliesTo": "filler type expansion joint"
    },
    {
      "label": "Selected earth fill cohesion",
      "value": "c=0",
      "unit": "",
      "appliesTo": "selected earth fill"
    },
    {
      "label": "Selected earth fill friction angle",
      "value": "φ 30°",
      "unit": "°",
      "appliesTo": "selected earth fill"
    },
    {
      "label": "Selected earth fill unit weight",
      "value": "γ = 20.0",
      "unit": "T/m³",
      "appliesTo": "selected earth fill"
    },
    {
      "label": "Concrete grade",
      "value": "M35",
      "unit": "",
      "appliesTo": "R.C.C. box cast in situ portion"
    },
    {
      "label": "Concrete grade",
      "value": "M40",
      "unit": "",
      "appliesTo": "crash barrier"
    },
    {
      "label": "Concrete grade",
      "value": "M30",
      "unit": "",
      "appliesTo": "approach slab"
    },
    {
      "label": "Concrete grade",
      "value": "M15",
      "unit": "",
      "appliesTo": "PCC below approach slab"
    },
    {
      "label": "Concrete grade",
      "value": "M10",
      "unit": "",
      "appliesTo": "PCC below founding level of RCC box"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "reinforcing steel bars"
    },
    {
      "label": "Clear cover at bottom slab and side wall earth faces",
      "value": "75mm",
      "unit": "mm",
      "appliesTo": "bottom slab & side wall"
    },
    {
      "label": "Clear cover at bottom slab and side wall inside faces",
      "value": "45mm",
      "unit": "mm",
      "appliesTo": "bottom slab & side wall"
    },
    {
      "label": "Clear cover at top slab on both faces",
      "value": "45mm",
      "unit": "mm",
      "appliesTo": "top slab"
    },
    {
      "label": "Wearing course thickness",
      "value": "50mm",
      "unit": "mm",
      "appliesTo": "wearing course"
    },
    {
      "label": "Minimum BC thickness for cross road",
      "value": "40mm",
      "unit": "mm",
      "appliesTo": "BC for cross road"
    },
    {
      "label": "ROW at underpass location",
      "value": "6.0m",
      "unit": "m",
      "appliesTo": "underpass location"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.",
    "5. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: c=0, φ 30°, γ = 20.0 T/m³.",
    "6. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- R.C.C. BOX CAST IN SITU PORTION — M35; CRASH BARRIER — M40; APPROACH SLAB — M30; GRADE OF PCC BELOW APPROACH SLAB — M15; GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX — M10.",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).",
    "8. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "9. THE STRUCTURE FALLS IN SEISMIC ZONE III.",
    "10. THE DESIGN ARE APPLICABLE FOR SEVERE CONDITIONS OF EXPOSURE.",
    "11. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.",
    "12. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS: BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm; BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm; TOP SLAB ON BOTH FACES = 45mm.",
    "14. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.",
    "15. THE ROW AT UNDERPASS LOCATION IS 6.0m.",
    "16. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY."
  ],
  "labels": [
    "DETAIL Z",
    "(SCALE 1:25)",
    "NOTES:",
    "LEGEND:",
    "FRL — FINISHED ROAD LEVEL",
    "CRL — CROSS ROAD LEVEL"
  ],
  "description": "This crop is a general notes block titled DETAIL Z, with a scale of 1:25. It documents design, material-grade, backfill, reinforcement cover, loading, exposure, road-level legend, and construction requirements for a structure including an RCC box, approach slab, crash barrier, and cross road."
}

p01_r02 general design notes material grades and legendNotes

  • filler type expansion jointSpecified in Note 4.

1:25 Scale20mm mm Filler type expansions joints widthc=0 Selected earth fill cohesionφ 30° ° Selected earth fill friction angleγ = 20.0 T/m³ Selected earth fill unit weightM35 Concrete gradeM40 Concrete gradeM30 Concrete grade+9 more

crop

p01_r02

page 1 · design_notes_and_legend_p01_r02
Original
p01_r02
{
  "view": "Notes",
  "objects": [
    {
      "name": "Filler type expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Specified to be provided."
    },
    {
      "name": "Structure",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Backfilling is specified on both sides."
    },
    {
      "name": "R.E. wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Selected earth fill behind wall is specified."
    },
    {
      "name": "R.C.C. box cast in situ portion",
      "tag": "",
      "shape": "",
      "material": "concrete, M35",
      "count": null,
      "note": ""
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete, M40",
      "count": null,
      "note": "Reference miscellaneous drawings for details."
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete, M30",
      "count": null,
      "note": "PCC below approach slab is specified as M15."
    },
    {
      "name": "PCC below approach slab",
      "tag": "",
      "shape": "",
      "material": "PCC, M15",
      "count": null,
      "note": ""
    },
    {
      "name": "PCC below founding level of RCC box",
      "tag": "",
      "shape": "",
      "material": "PCC, M10",
      "count": null,
      "note": ""
    },
    {
      "name": "Reinforcing steel bars",
      "tag": "",
      "shape": "",
      "material": "high yield strength deformed (TMT) bars, Grade-Fe 550D",
      "count": null,
      "note": ""
    },
    {
      "name": "Cover slab for footpath",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Reference miscellaneous drawings for details."
    },
    {
      "name": "Bottom slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Clear reinforcement cover is specified at earth and inside faces."
    },
    {
      "name": "Side wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Clear reinforcement cover is specified at earth and inside faces."
    },
    {
      "name": "Top slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Clear reinforcement cover and wearing course are specified."
    },
    {
      "name": "Wearing course",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Provided over top slab."
    },
    {
      "name": "BC for cross road",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Minimum thickness specified."
    }
  ],
  "measurements": [
    {
      "label": "Scale",
      "value": "1:25",
      "unit": "",
      "appliesTo": "DETAIL Z"
    },
    {
      "label": "Filler type expansion joint width",
      "value": "20",
      "unit": "mm",
      "appliesTo": "Filler type expansion joints"
    },
    {
      "label": "C",
      "value": "0",
      "unit": "",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "φ",
      "value": "> 30°",
      "unit": "",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "γ",
      "value": "2.0",
      "unit": "T/m³",
      "appliesTo": "Selected earth fill behind RE wall"
    },
    {
      "label": "Concrete grade",
      "value": "M35",
      "unit": "",
      "appliesTo": "R.C.C. box cast in situ portion"
    },
    {
      "label": "Concrete grade",
      "value": "M40",
      "unit": "",
      "appliesTo": "Crash barrier"
    },
    {
      "label": "Concrete grade",
      "value": "M30",
      "unit": "",
      "appliesTo": "Approach slab"
    },
    {
      "label": "PCC grade",
      "value": "M15",
      "unit": "",
      "appliesTo": "PCC below approach slab"
    },
    {
      "label": "PCC grade",
      "value": "M10",
      "unit": "",
      "appliesTo": "PCC below founding level of RCC box"
    },
    {
      "label": "Reinforcing steel grade",
      "value": "Fe 550D",
      "unit": "",
      "appliesTo": "Reinforcing steel"
    },
    {
      "label": "Design loading",
      "value": "FOUR LANE OF CLASS A",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Design loading",
      "value": "ONE LANE CLASS 70R + TWO LANE OF CLASS A",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Design loading",
      "value": "ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Seismic zone",
      "value": "III",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Clear cover, bottom slab & side wall (earth faces)",
      "value": "75",
      "unit": "mm",
      "appliesTo": "Reinforcement"
    },
    {
      "label": "Clear cover, bottom slab & side wall (inside faces)",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Reinforcement"
    },
    {
      "label": "Clear cover, top slab on both faces",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Reinforcement"
    },
    {
      "label": "Wearing course thickness",
      "value": "50",
      "unit": "mm",
      "appliesTo": "Top slab"
    },
    {
      "label": "Minimum BC thickness",
      "value": "40",
      "unit": "mm",
      "appliesTo": "Cross road"
    },
    {
      "label": "ROW at underpass location",
      "value": "60",
      "unit": "m",
      "appliesTo": "Underpass location"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "4. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.",
    "5. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: C=0 . φ> 30°, γ = 2.0 T/m³.",
    "6. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-",
    "• R.C.C. BOX CAST IN SITU PORTION ------ M35",
    "• CRASH BARRIER ------ M40",
    "• APPROACH SLAB ------ M30",
    "• GRADE OF PCC BELOW APPROACH SLAB ------ M15",
    "• GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX------ M10",
    "7. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).",
    "8. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "9. THE STRUCTURE FALLS IN SEISMIC ZONE III.",
    "10. THE DESIGN ARE APPLICABLE FOR “SEVERE” CONDITIONS OF EXPOSURE",
    "11. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.",
    "12. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS:",
    "• BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm",
    "• BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm",
    "• TOP SLAB ON BOTH FACES = 45mm",
    "14. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.",
    "15. THE ROW AT UNDERPASS LOCATION IS 60m.",
    "16. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY."
  ],
  "labels": [
    "DETAIL Z",
    "(SCALE 1:25)",
    "NOTES:",
    "LEGEND:",
    "1. FRL ........ FINISHED ROAD LEVEL",
    "2. CRL ........ CROSS ROAD LEVEL"
  ],
  "description": "This crop is a general notes block for a structure detail, headed DETAIL Z, together with a short level-abbreviation legend. It specifies design, materials, loading, backfill, reinforcement cover, slab surfacing, and approach-work requirements; no physical plan, elevation, or section geometry is shown in this crop."
}

p01_r02Notes

  • Filler type expansion jointSpecified to be provided.

1:25 Scale20 mm Filler type expansion joint width0 C> 30° φ2.0 T/m³ γM35 Concrete gradeM40 Concrete gradeM30 Concrete grade+13 more

crop

p01_r04

page 1 · typical_road_cross_section_with_re_wall_and_crash_barrier_p01_r04
Original
p01_r04
{
  "view": "Cross Section",
  "objects": [
    {
      "name": "bridge deck",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Two deck widths are shown, separated at the centreline by a labelled gap."
    },
    {
      "name": "crash barrier",
      "tag": "",
      "shape": "profiled barrier",
      "material": "",
      "count": 2,
      "note": "Located at the outer edges of the deck."
    },
    {
      "name": "RE wall",
      "tag": "",
      "shape": "battered/tapered",
      "material": "",
      "count": 2,
      "note": "One retaining wall is shown at each outside edge."
    },
    {
      "name": "compacted non-plastic granular fill",
      "tag": "",
      "shape": "rectangular strip",
      "material": "sand/gravel",
      "count": 1,
      "note": "Stippled fill layer shown beneath the structure."
    },
    {
      "name": "service road",
      "tag": "",
      "shape": "horizontal roadway strip",
      "material": "",
      "count": 2,
      "note": "One shown on each side of the structure."
    },
    {
      "name": "shoulder",
      "tag": "",
      "shape": "horizontal roadway strip",
      "material": "",
      "count": 2,
      "note": "One shown outside each service road."
    },
    {
      "name": "expansion gap",
      "tag": "",
      "shape": "linear joint",
      "material": "",
      "count": 1,
      "note": "Centred at the C/L OF STRUCTURE."
    }
  ],
  "measurements": [
    {
      "label": "right-of-way width",
      "value": "60000",
      "unit": "",
      "appliesTo": "ROW"
    },
    {
      "label": "shoulder width",
      "value": "1000",
      "unit": "",
      "appliesTo": "left shoulder"
    },
    {
      "label": "service road width",
      "value": "7000",
      "unit": "",
      "appliesTo": "left service road"
    },
    {
      "label": "crash barrier offset/width",
      "value": "500",
      "unit": "",
      "appliesTo": "left crash barrier"
    },
    {
      "label": "total deck width",
      "value": "15100",
      "unit": "",
      "appliesTo": "left deck"
    },
    {
      "label": "deck crossfall",
      "value": "2.5",
      "unit": "%",
      "appliesTo": "left deck"
    },
    {
      "label": "gap",
      "value": "10",
      "unit": "mm",
      "appliesTo": "expansion gap"
    },
    {
      "label": "total deck width",
      "value": "15100",
      "unit": "",
      "appliesTo": "right deck"
    },
    {
      "label": "deck crossfall",
      "value": "2.5",
      "unit": "%",
      "appliesTo": "right deck"
    },
    {
      "label": "crash barrier offset/width",
      "value": "500",
      "unit": "",
      "appliesTo": "right crash barrier"
    },
    {
      "label": "service road width",
      "value": "7000",
      "unit": "",
      "appliesTo": "right service road"
    },
    {
      "label": "shoulder width",
      "value": "1000",
      "unit": "",
      "appliesTo": "right shoulder"
    },
    {
      "label": "RE wall slope",
      "value": "1:1.5",
      "unit": "",
      "appliesTo": "left RE wall"
    },
    {
      "label": "RE wall crossfall",
      "value": "2.5",
      "unit": "%",
      "appliesTo": "left RE wall"
    },
    {
      "label": "RE wall slope",
      "value": "1:1.5",
      "unit": "",
      "appliesTo": "right RE wall"
    },
    {
      "label": "RE wall crossfall",
      "value": "2.5",
      "unit": "%",
      "appliesTo": "right RE wall"
    },
    {
      "label": "typical dimension",
      "value": "1000",
      "unit": "",
      "appliesTo": "compacted non-plastic granular fill"
    },
    {
      "label": "scale",
      "value": "1:225",
      "unit": "",
      "appliesTo": "SECTION A-A"
    },
    {
      "label": "shoulder width",
      "value": "1000",
      "unit": "",
      "appliesTo": "lower partial view, left shoulder"
    },
    {
      "label": "service road width",
      "value": "7000",
      "unit": "",
      "appliesTo": "lower partial view, left service road"
    },
    {
      "label": "total deck width",
      "value": "15100",
      "unit": "",
      "appliesTo": "lower partial view, left deck"
    },
    {
      "label": "total deck width",
      "value": "15100",
      "unit": "",
      "appliesTo": "lower partial view, right deck"
    },
    {
      "label": "service road width",
      "value": "7000",
      "unit": "",
      "appliesTo": "lower partial view, right service road"
    },
    {
      "label": "shoulder width",
      "value": "1000",
      "unit": "",
      "appliesTo": "lower partial view, right shoulder"
    }
  ],
  "notes": [
    "COMPACTED NON-PLASTIC GRANULAR FILL (SAND/GRAVEL) (Ø>30°)"
  ],
  "labels": [
    "ROW",
    "SHOULDER",
    "SERVICE ROAD",
    "C/L OF LHS",
    "C/L OF RHS",
    "C/L OF STRUCTURE",
    "C/L OF MEDIAN",
    "SECTION A-A",
    "(SCALE 1:225)",
    "TOTAL DECK WIDTH",
    "TYP.",
    "NEW JERSEY BARRIER"
  ],
  "description": "This crop shows Section A-A through a divided deck/roadway arrangement within a 60000 ROW. Two 15100 total deck widths meet at a 10 mm central gap, with crash barriers, service roads, shoulders, and RE walls at the outside edges. A compacted non-plastic granular fill layer is shown below the structure; a lower partial adjacent view contains repeated roadway-width dimensions and partial New Jersey barrier labels."
}

p01_r04Cross Section

  • expansion gap×1linear jointCentred at the C/L OF STRUCTURE.

60000 right-of-way width1000 shoulder width7000 service road width500 crash barrier offset/width15100 total deck width2.5 % deck crossfall10 mm gap15100 total deck width+16 more