Notes on the sheets that carry it
- p11. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
- p12. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
- p13. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
- p14. FILLER TYPE EXPANSIONS JOINTS OF 20mm WIDTH ARE TO BE PROVIDED.
- p15. THE BACKFILLING ON BOTH SIDE OF THE STRUCTURE SHOULD BE DONE SIMULTANEOUSLY. THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES: C=0 . φ> 30°, γ = 2.0 T/m³.
- p16. GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:-
- p1• R.C.C. BOX CAST IN SITU PORTION ------ M35
- p1• CRASH BARRIER ------ M40
- p1• APPROACH SLAB ------ M30
- p1• GRADE OF PCC BELOW APPROACH SLAB ------ M15
- p1• GRADE OF PCC BELOW FOUNDING LEVEL OF RCC BOX------ M10
- p17. ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS (GRADE-Fe 550D).
- p18. THE STRUCTURE IS DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
- p19. THE STRUCTURE FALLS IN SEISMIC ZONE III.
- p110. THE DESIGN ARE APPLICABLE FOR “SEVERE” CONDITIONS OF EXPOSURE
- p111. FOR DETAILS OF CRASH BARRIER, APPROACH SLAB & COVER SLAB FOR FOOTPATH REFER MISCELLANEOUS DRAWINGS.
- p112. CLEAR COVER FOR REINFORCEMENT SHALL BE AS PER FOLLOWS:
- p1• BOTTOM SLAB & SIDE WALL (EARTH FACES) = 75mm
- p1• BOTTOM SLAB & SIDE WALL (INSIDE FACES) = 45mm
- p1• TOP SLAB ON BOTH FACES = 45mm
- p114. 50mm THICK WEARING COURSE IS PROVIDED OVER TOP SLAB AND MINIMUM 40mm THICK BC FOR CROSS ROAD.
- p115. THE ROW AT UNDERPASS LOCATION IS 60m.
- p116. DETAILS OF APPROACH PORTION SHALL BE VERIFIED FROM HIGHWAY DRAWINGS AND SHALL BE CONSTRUCTED ACCORDINGLY.
Every crop it was read in — the drawing beside what the model took off it
Page 1
crop
p01_r02Notes
- Bottom slabClear reinforcement cover is specified at earth and inside faces.
1:25 Scale20 mm Filler type expansion joint width0 C> 30° φ2.0 T/m³ γM35 Concrete gradeM40 Concrete gradeM30 Concrete grade+13 more